2,042 research outputs found

    On Adequacy of Two-point Averaging Schemes for Composites with Nonlinear Viscoelastic Phases

    Get PDF
    Finite element simulations on fibrous composites with nonlinear viscoelastic response of the matrix phase are performed to explain why so called two-point averaging schemes may fail to deliver a realistic macroscopic response. Nevertheless, the potential of two-point averaging schemes (the overall response estimated in terms of localized averages of a two-phase composite medium) has been put forward in number of studies either in its original format or modified to overcome the inherited stiffness of classical ”elastic” localization rules. However, when the material model and geometry of the microstructure promote the formation of shear bands, none of the existing two-point averaging schemes will provide an adequate macroscopic response, since they all fail to capture the above phenomenon. Several examples are presented here to support this statement.

    A 5-W GaN Doherty Amplifier for Ka-Band Satellite Downlink With 4-GHz Bandwidth and 17-dB NPR

    Get PDF
    This letter presents the design and experimental characterization of a GaN-Si monolithic Doherty power amplifier (PA) for the Ka-band satellite downlink. The fabricated amplifier favorably compares with the current state of the art, achieving from 16.3 to 20.3 GHz (4 GHz, 22% relative bandwidth), a record band to date, 36.6-37.7-dBm output power, 23%-31% power-added efficiency, 18-22-dB gain at saturation, and around 20% power-added efficiency at 6-dB output back-off. At 18.8 GHz, the amplifier shows a noise-to-power ratio higher than 17 dB at all power levels, making it suitable for satellite applications where additional linearization is usually unfeasible

    Investigation of top mass measurements with the ATLAS detector at LHC

    Full text link
    Several methods for the determination of the mass of the top quark with the ATLAS detector at the LHC are presented. All dominant decay channels of the top quark can be explored. The measurements are in most cases dominated by systematic uncertainties. New methods have been developed to control those related to the detector. The results indicate that a total error on the top mass at the level of 1 GeV should be achievable.Comment: 47 pages, 40 figure

    Photonic band-gap effects on photoluminescence of silicon nanocrystals embedded in artificial opals

    No full text
    Si nanocrystals were formed in synthetic opals by Si-ion implantation and their optical properties studied using microphotoluminescence and reflection techniques. The properties of areas with high crystalline quality are compared with those of disordered regions of samples. The photoluminescencespectrum from Si nanocrystals embedded in silica spheres is narrowed by the inhibition of emission at wavelengths corresponding to the opalphotonic pseudoband gap (∼690 nm). Measurements of photoluminescencespectra from individual implanted silica spheres is also demonstrated and the number of emitting Si nanocrystals in single brightly emitting spheres is estimated to be of the order of one thousand.This work was supported by GACR (202/03/0789), NATO (PST.CLG.978100), and by the Royal Swedish Academy of Sciences. One of the authors ~J.V.! appreciates financial support from the French government (program Echange)

    Active planar optical waveguide made from luminescent silicon nanocrystals

    No full text
    We show experimentally that a layer of silicon nanocrystals, prepared by the Si-ion implantation (with the energy of 400 keV) into a synthetic silica slab and exhibiting room-temperature red photoluminescence, can serve simultaneously as a single-mode planar optical waveguide. The waveguide is shown to self-select guided transverse electric and transverse magnetic modes from the broad photoluminescence emission of the nanocrystals resulting in a substantially narrower emission spectrum for these modes. We further report on an investigation of optical gain in a sample implanted to a dose of 4×1017 cm−2. Despite the occurrence of strong waveguiding, results of the variable stripe length method turned out not to be able to give unambiguous evidence for optical gai

    Rotating Gliding Arc: Innovative Source for VOC Remediation

    Get PDF
    The large-scale plasma treatment of waste gas in industrial or municipal conditions requires high efficiency of plasma conversion process at high processing speed, i.e., large volumetric flow. The integration of the plasma unit into existing systems puts demands on the pipe-system compatibility and minimal pressure drop due to adoption of plasma processing step. These conditions are met at the innovative rotating electrode gliding arc plasma unit described in this article. The system consists of propeller-shaped high voltage electrode inside grounded metallic tube. The design of HV electrode eliminates the pressure drop inside the air system, contrary the plasma unit itself is capable of driving the waste gas at volumetric flow up to 300 m3/hr for 20 cm pipe diameter. In the article the first results on pilot study of waste air treatment will be given for selected volatile organic compounds together with basic characteristic of the plasma unit used

    Nuclear myocardial perfusion imaging with a cadmium-zinc-telluride detector technique: optimized protocol for scan time reduction

    Full text link
    We aimed at establishing the optimal scan time for nuclear myocardial perfusion imaging (MPI) on an ultrafast cardiac gamma-camera using a novel cadmium-zinc-telluride (CZT) solid-state detector technology. METHODS: Twenty patients (17 male; BMI range, 21.7-35.5 kg/m(2)) underwent 1-d (99m)Tc-tetrofosmin adenosine stress and rest MPI protocols, each with a 15-min acquisition on a standard dual-detector SPECT camera. All scans were immediately repeated on an ultrafast CZT camera over a 6-min acquisition time and reconstructed from list-mode raw data to obtain scan durations of 1 min, 2 min, etc., up to a maximum of 6 min. For each of the scan durations, the segmental tracer uptake value (percentage of maximum myocardial uptake) from the CZT camera was compared by intraclass correlation with standard SPECT camera data using a 20-segment model, and clinical agreement was assessed per coronary territory. Scan durations above which no further relevant improvement in uptake correlation was found were defined as minimal required scan times, for which Bland-Altman limits of agreement were calculated. RESULTS: Minimal required scan times were 3 min for low dose (r = 0.81; P < 0.001; Bland-Altman, -11.4% to 12.2%) and 2 min for high dose (r = 0.80; P < 0.001; Bland-Altman, -7.6% to 12.9%), yielding a clinical agreement of 95% and 97%, respectively. CONCLUSION: We have established the minimal scan time for a CZT solid-state detector system, which allows 1-d stress/rest MPI with a substantially reduced acquisition time resulting in excellent agreement with regard to uptake and clinical findings, compared with MPI from a standard dual-head SPECT gamma-camera

    Vacancy-mediated dopant diffusion activation enthalpies for germanium

    Get PDF
    Electronic structure calculations are used to predict the activation enthalpies of diffusion for a range of impurity atoms (aluminium, gallium, indium, silicon, tin, phosphorus, arsenic, and antimony) in germanium. Consistent with experimental studies, all the impurity atoms considered diffuse via their interaction with vacancies. Overall, the calculated diffusion activation enthalpies are in good agreement with the experimental results, with the exception of indium, where the most recent experimental study suggests a significantly higher activation enthalpy. Here, we predict that indium diffuses with an activation enthalpy of 2.79 eV, essentially the same as the value determined by early radiotracer studies
    corecore