266 research outputs found
Magic Triangle – Human, Exoskeleton, and Collaborative Robot Scenario
The incidence of musculoskeletal disorders in workplaces with difficult ergonomic conditions is increasing. Today, there is a growing market for technical support systems that avoid repetitive strain on the musculoskeletal system. We have been observing two (parallel) lines of development: on the one hand, the development of exoskeletons supporting shop floor operators and, on the other hand, the development of collaborative robots for the creation of hybrid teams. The focus of our research is the combined application of exoskeletons AND collaborative robots for shop floor operators in the aerospace industry. Our approach is to analyze various scenarios to understand which tasks should preferably be executed either with a collaborative robot, with an exoskeleton, or by a human without assistance from any support systems such as an exoskeleton or robot. In order to pursue this idea of modular and selective support system solutions, tool availability has to be ensured without increasing the required infrastructure. In a first step, we have developed a prototype of a tool adapter that enables the application of a tool either by connection to a robot, an exoskeleton, or the tool being held by the operator, and allows very fast coupling and decoupling within seconds. This concept will enable the realization of the proposed simultaneous use of exoskeletons and robots
Angiographic predictors of recurrence of restenosis after Wiktor stent implantation in native coronary arteries
Intracoronary stenting has been proposed as an adjunct to balloon angioplasty to improve the immediate and long-term results. However, late luminal narrowing has been reported following the implantation of a variety of stents. One of the studies conducted with the Wiktor stent is a prospective registry designed to evaluate the feasibility, safety and efficacy of elective stent implantation in patients with documented restenosis of a native coronary artery. To identify angiographic variables predicting recurrence of restenosis, the angiograms of the first 91 patients with successful stent implantation and without clinical evidence of (sub)acute thrombotic stent occlusion were analyzed with the Computer Assisted Angiographic Analysis System using automated edge detection. The incidence of restenosis was 44% by patient and 45% by stent according to the 0.72 mm criterion, and 30% by patient and 29% by stent according to the 50% diameter stenosis criterion. The risk for restenosis for several angiographic variables was determined using an univariate analysis and is expressed as odds ratio with corresponding confidence interval. The only statistically significant predictor of restenosis was the relative gain when it exceeded 0.48 using the 0.72 mm criterion (odds ratio 2.7, 95% confidence interval 1.1-6.4). Furthermore, the relation between the relative gain (increase in minimal luminal diameter normalized to vessel size) as angiographic index of vessel wall injury and relative loss (decrease in minimal luminal diameter normalized to vessel size) as index of neointimal thickening was analyzed using a linear regression analysis. When using the categorical approach to address restenosis, there is an increased risk for recurrent restenosis when the relative gain exceeds 0.48. The continuous approach underscores this concept by indicating a weak but positive relation between the relative gain and relative loss
Long-term fluvastatin reduces the hazardous effect of renal impairment on four-year atherosclerotic outcomes (a LIPS substudy)
peer reviewedMild renal impairment is an important risk factor for late cardiovascular complications. This substudy of the Lescol Intervention Prevention Study (LIPS) assessed the effect of fluvastatin on outcome of patients who had renal dysfunction and those who did not. Complete data for creatinine clearance calculation. (Cockcroft=Gault formula) were available for 1,558 patients (92.9% of the LIPS population). Patients were randomized to fluvastatin or placebo after successful completion of a first percutaneous coronary intervention. Follow-up time was, 3 to 4 years. The effect of baseline creatinine clearance on coronary atherosclerotic events (cardiac death, non-fatal myocardial infarction, and coronary reinterventions not related to restenosis) was evaluated. Baseline creatinine clearance (logarithmic transformation) was inversely associated with an incidence of adverse events among patients who received, placebo. (hazard ratio 0.99, 95% confidence interval 0.982 to 0.998, p = 0.01). However, no association was noted between creatinine clearance and the incidence of adverse events among patients who received fluvastatin (hazard ratio 1.0, 95% confidence interval 0.99 to 1.0, p = 0.63). No further deterioration in creatinine clearance was observed during follow-up; regardless of baseline renal function or allocated treatment. Occurrence of adverse events was not related to changes in renal function during follow-up. Fluvastatin therapy markedly decreased the risk of coronary atherosclerotic events after percutaneous intervention in: patients who had lower values of creatinine clearance at baseline: The benefit of fluvastatin was unrelated to any effect on renal function. (C) 2005 by Excerpta Medica Inc
Recoil following Wiktor stent implantation for restenotic lesions of coronary arteries
The purpose of this study was to determine acute recoil of the vessel wall immediately after Wiktor stent implantation in native coronary arteries of 77 consecutive patients and to assess whether there was compression or “late recoil” of the stent itself at long-term follow-up. Furthermore, the relationship between recoil and a number of clinical, angiographic, and procedural variables was studied in addition to the relation between acute recoil renarrowing or restenosis was assessed. All angiograms were analyzed with the Cardiovascular Angiography Analysis System using automated edge detection. Acute recoil was defined by the difference between the mean diameter of the fully expanded balloon on which the stent was mounted and the mean diameter of the stented segment. Late recoil was calculated by comparing the mean diameter of the stent itself immediately after implantation and at follow-up without opacification of the vessel.
Acute recoil amounted to 0.25 ± 0.32 mm or 8.2%. Multivariate analysis identified sex (coefficient = –0.20, p = 0.04) and stent/artery ratio (coefficient = 0.99, p = 0.0001) as the only independent predictors of acute recoil. “Late recoil” of the stent itself was not observed. The overall difference between the mean diameter of the stent itself immediately after implantation and at follow-up was –0.15 ± 0.33 mm, suggesting an overall increase in diameter of 5.0%. There was no relation between acute recoil and late restenosis. On the contrary, there was a trend towards a greater degree of recoil in patients without restenosis. Moreover, linear regression analysis disclosed a weak but negative correlation between acute recoil and a loss in minimal luminal diameter (coefficient: –0.55, p = 0.04).
The Wiktor stent effectively scaffolds the instrumented vessel. Only a minimal amount of acute recoil was noted, which did not contribute to late luminal renarrowing or restenosis. In addition, no late compression of the stent itself was observed. These data suggest that tissue ingrowth into the lumen of the stented segment is the main cause of late luminal renarrowing after stent implantation. © 1994 Wiley-Liss,Inc.
A comparison of hirudin with heparin in the prevention of restenosis after coronary angioplasty
__Background:__ The likelihood of restenosis is a major limitation of coronary angioplasty. We studied whether hirudin, a highly selective inhibitor of thrombin with irreversible effects, would prevent restenosis after angioplasty. We compared two regimens of recombinant hirudin with heparin.
__Methods:__ We randomly assigned 1141 patients with unstable angina who were scheduled for angioplasty to receive one of three treatments: (1) a bolus dose of 10,000 IU of heparin followed by an intravenous infusion of heparin for 24 hours and subcutaneous placebo twice daily for three days (382 patients), (2) a bolus dose of 40 mg of hirudin followed by an intravenous infusion of hirudin for 24 hours and subcutaneous placebo twice daily for three days (381 patients), or (3) the same hirudin regimen except that 40 mg of hirudin was given subcutaneously instead of placebo twice daily for three days (378 patients). The primary end point was event-free survival at seven months. Other end points were early cardiac events (within 96 hours), bleeding and other complications of the study treatment, and angiographic measurements of coronary diameter at six months of follow-up.
__Results:__ At seven months, event-free survival was 67.3 percent in the group receiving heparin, 63.5 percent in the group receiving intravenous hirudin, and 68.0 percent in the group receiving both intravenous and subcutaneous hirudin (P=0.61). However, the administration of hirudin was associated with a significant reduction in early cardiac events, which occurred in 11.0, 7.9, and 5.6 percent of patients in the respective groups (combined relative risk with hirudin, 0.61; 95 percent confidence interval, 0.41 to 0.90; P=0.023). The mean minimal luminal diameters in the respective groups on follow-up angiography at six months were 1.54, 1.47, and 1.56 mm.
__Conclusions:__ Although significantly fewer early cardiac events occurred with hirudin than with heparin, hirudin had no apparent benefit with longer-term follow-up
Usefulness of quantitative and qualitative angiographic lesion morphology, and clinical characteristics in predicting major adverse cardiac events during and after native coronary balloon angioplasty
Major, adverse cardiac events (death, myocardial infarction, bypass surgery and reintervention) occur in 4 to 7% of all patients undergoing coronary balloon angioplasty. Prospectively collected clinical data, and angiographic quantitative and qualitative lesion morphologic assessment and procedural factors were examined to determine whether the occurrence of these events could be predicted. Of 1,442 patients undergoing balloon angioplasty for native primary coronary disease in 2 European multicenter trials, 69 had major, adverse cardiac procedural or in-hospital complications after ≥1 balloon inflation and were randomly matched with patients who completed an uncomplicated in-hospital course after successful angioplasty. No quantitative angiographic variable was associated with major adverse cardiac events in univariate and multivariate analyses. Univariate analysis showed that major adverse cardiac events were associated with the following preprocedural variables: (1) unstable angina (odds ratio [OR] 3.11; p 45 ° (OR 2.34; p 45 ° (OR 2.87; p 45 ° (OR 2.54; p < 0.006) were independent predictors of major adverse cardiac events
Carvedilol for prevention of restenosis after directional coronary atherectomy : final results of the European carvedilol atherectomy restenosis (EUROCARE) trial
BACKGROUND: In addition to its known properties as a competitive,
nonselective beta and alpha-1 receptor blocker, carvedilol directly
inhibits vascular myocyte migration and proliferation and exerts
antioxidant effects that are considerably greater than those of vitamin E
or probucol. This provides the basis for an evaluation of carvedilol for
the prevention of coronary restenosis. METHODS AND RESULTS: In a
prospective, double-blind, randomized, placebo-controlled trial, 25 mg of
carvedilol was given twice daily, starting 24 h
Interventricular septum hematoma during cineventriculography
<p>Abstract</p> <p>Background</p> <p>Intraseptal hematoma and subsequent myocardial infarction due to accidental contrast agent deposition complicating diagnostic cineventriculography is a previously undescribed complication of angiography.</p> <p>Case presentation</p> <p>A 61 year old man was admitted at intensive care unit because of unstable angina pectoris 1 hour after coronary angiography. Transthoracic contrast echocardiography showed a non-perfused area in the middle of interventricular septum with an increase of thickening up to 26 mm. Review of cineventriculography revealed contrast enhancement in the interventricular septum after contrast medium injection and a dislocation of the pigtail catheter tip. Follow up by echocardiography and MRI showed, that intramural hematoma has resolved after 6 weeks. After 8 weeks successful stent implantation in LAD was performed and after 6 month the patient had a normal LV-function without ischemic signs or septal thickening demonstrated by stressechocardiography.</p> <p>Conclusion</p> <p>A safe and mobile position of the pigtail catheter during ventriculography in the middle of the LV cavity should be ensured to avoid this potentially life-threatening complication. For assessment and absolute measurement of intramural hematoma contrast-enhanced echocardiography is more feasible than MRI and makes interchangeable results.</p
- …