1,185 research outputs found

    Evidence-based planning and costing palliative care services for children : novel multi-method epidemiological and economic exemplar

    Get PDF
    Background: Children’s palliative care is a relatively new clinical specialty. Its nature is multi-dimensional and its delivery necessarily multi-professional. Numerous diverse public and not-for-profit organisations typically provide services and support. Because services are not centrally coordinated, they are provided in a manner that is inconsistent and incoherent. Since the first children’s hospice opened in 1982, the epidemiology of life-limiting conditions has changed with more children living longer, and many requiring transfer to adult services. Very little is known about the number of children living within any given geographical locality, costs of care, or experiences of children with ongoing palliative care needs and their families. We integrated evidence, and undertook and used novel methodological epidemiological work to develop the first evidence-based and costed commissioning exemplar. Methods: Multi-method epidemiological and economic exemplar from a health and not-for-profit organisation perspective, to estimate numbers of children under 19 years with life-limiting conditions, cost current services, determine child/parent care preferences, and cost choice of end-of-life care at home. Results: The exemplar locality (North Wales) had important gaps in service provision and the clinical network. The estimated annual total cost of current children’s palliative care was about £5.5 million; average annual care cost per child was £22,771 using 2007 prevalence estimates and £2,437- £11,045 using new 2012/13 population-based prevalence estimates. Using population-based prevalence, we estimate 2271 children with a life-limiting condition in the general exemplar population and around 501 children per year with ongoing palliative care needs in contact with hospital services. Around 24 children with a wide range of life-limiting conditions require end-of-life care per year. Choice of end-of-life care at home was requested, which is not currently universally available. We estimated a minimum (based on 1 week of end-of-life care) additional cost of £336,000 per year to provide end-of-life support at home. Were end-of-life care to span 4 weeks, the total annual additional costs increases to £536,500 (2010/11 prices). Conclusions: Findings make a significant contribution to population-based needs assessment and commissioning methodology in children’s palliative care. Further work is needed to determine with greater precision which children in the total population require access to services and when. Half of children who died 2002-7 did not have conditions that met the globally used children's palliative care condition categories, which need revision in light of findings

    Fluorodeoxyglucose positron emission tomography in the evaluation of germ cell tumours at relapse

    Get PDF
    Differentiation of active disease from fibrosis/mature teratoma in patients with residual masses or identifying of sites of recurrence in patients with raised markers following treatment of their testicular cancer remains a problem.18F-fluorodeoxyglucose positron emission tomography (FDG-PET) has the potential to identify active disease and thereby influence further management in these patients. We performed a retrospective study of the use of FDG-PET in detecting residual/recurrent testicular carcinoma in 55 patients (seventy FDG-PET scans). Forty-seven scans were for the assessment of residual masses (18 had raised markers) and 23 scans were for the investigation of raised markers in the presence of normal CT scans. True positive results were based on positive histology or clinical follow-up. FDG-PET had a positive predictive value (PPV) of 96% and a negative predictive value (NPV) of 90% in patients with residual masses. This PPV was equivalent to that of markers (94%) but FDG-PET had the advantage of identifying the site of that recurrence. The NPV was higher than that of markers. In patients with raised markers alone the PPV of FDG-PET was 92% but the NPV was only 50%. However, subsequent FDG-PET imaging was frequently the first imaging modality to identify the site of disease. FDG-PET effected a management change in 57% of cases. FDG-PET scanning detected viable tumour in residual masses and identified sites of disease in suspected recurrence. © 2000 Cancer Research Campaig

    Superpotentials for M-theory on a G_2 holonomy manifold and Triality symmetry

    Get PDF
    For MM-theory on the G2G_2 holonomy manifold given by the cone on {\bf S^3}\x {\bf S^3} we consider the superpotential generated by membrane instantons and study its transformations properties, especially under monodromy transformations and triality symmetry. We find that the latter symmetry is, essentially, even a symmetry of the superpotential. As in Seiberg/Witten theory, where a flat bundle given by the periods of an universal elliptic curve over the uu-plane occurs, here a flat bundle related to the Heisenberg group appears and the relevant universal object over the moduli space is related to hyperbolic geometry.Comment: 58 pages, latex; references adde

    Towards an integrated soil moisture drought monitor for East Africa

    Get PDF
    Drought in East Africa is a recurring phenomenon with significant humanitarian impacts. Given the steep climatic gradients, topographic contrasts, general data scarcity, and, in places, political instability that characterize the region, there is a need for spatially distributed, remotely derived monitoring systems to inform national and international drought response. At the same time, the very diversity and data scarcity that necessitate remote monitoring also make it difficult to evaluate the reliability of these systems. Here we apply a suite of remote monitoring techniques to characterize the temporal and spatial evolution of the 2010–2011 Horn of Africa drought. Diverse satellite observations allow for evaluation of meteorological, agricultural, and hydrological aspects of drought, each of which is of interest to different stakeholders. Focusing on soil moisture, we apply triple collocation analysis (TCA) to three independent methods for estimating soil moisture anomalies to characterize relative error between products and to provide a basis for objective data merging. The three soil moisture methods evaluated include microwave remote sensing using the Advanced Microwave Scanning Radiometer – Earth Observing System (AMSR-E) sensor, thermal remote sensing using the Atmosphere-Land Exchange Inverse (ALEXI) surface energy balance algorithm, and physically based land surface modeling using the Noah land surface model. It was found that the three soil moisture monitoring methods yield similar drought anomaly estimates in areas characterized by extremely low or by moderate vegetation cover, particularly during the below-average 2011 long rainy season. Systematic discrepancies were found, however, in regions of moderately low vegetation cover and high vegetation cover, especially during the failed 2010 short rains. The merged, TCA-weighted soil moisture composite product takes advantage of the relative strengths of each method, as judged by the consistency of anomaly estimates across independent methods. This approach holds potential as a remote soil moisture-based drought monitoring system that is robust across the diverse climatic and ecological zones of East Africa

    An Initial Assessment of a SMAP Soil Moisture Disaggregation Scheme Using TIR Surface Evaporation Data over the Continental United States

    Get PDF
    The Soil Moisture Active Passive (SMAP) mission is dedicated toward global soil moisture mapping. Typically, an L-band microwave radiometer has spatial resolution on the order of 36-40 km, which is too coarse for many specific hydro-meteorological and agricultural applications. With the failure of the SMAP active radar within three months of becoming operational, an intermediate (9-km) and finer (3-km) scale soil moisture product solely from the SMAP mission is no longer possible. Therefore, the focus of this study is a disaggregation of the 36-km resolution SMAP passive-only surface soil moisture (SSM) using the Soil Evaporative Efficiency (SEE) approach to spatial scales of 3-km and 9-km. The SEE was computed using thermal-infrared (TIR) estimation of surface evaporation over Continental U.S. (CONUS). The disaggregation results were compared with the 3 months of SMAP-Active (SMAP-A) and Active/Passive (AP) products, while comparisons with SMAP-Enhanced (SMAP-E), SMAP-Passive (SMAP-P), as well as with more than 180 Soil Climate Analysis Network (SCAN) stations across CONUS were performed for a 19 month period. At the 9-km spatial scale, the TIR-Downscaled data correlated strongly with the SMAP-E SSM both spatially (r = 0.90) and temporally (r = 0.87). In comparison with SCAN observations, overall correlations of 0.49 and 0.47; bias of 0.022 and 0.019 and unbiased RMSD of 0.105 and 0.100 were found for SMAP-E and TIR-Downscaled SSM across the Continental U.S., respectively. At 3-km scale, TIR-Downscaled and SMAP-A had a mean temporal correlation of only 0.27. In terms of gain statistics, the highest percentage of SCAN sites with positive gains (>55%) was observed with the TIR-Downscaled SSM at 9-km. Overall, the TIR-based downscaled SSM showed strong correspondence with SMAP-E; compared to SCAN, and overall both SMAP-E and TIR-Downscaled performed similarly, however, gain statistics show that TIR-Downscaled SSM slightly outperformed SMAP-E

    Sharpening ECOSTRESS and VIIRS Land Surface Temperature Using Harmonized Landsat-Sentinel Surface Reflectances

    Get PDF
    Land surface temperature (LST) is a key diagnostic indicator of agricultural water use and crop stress. LST data retrieved from thermal infrared (TIR) band imagery, however, tend to have a coarser spatial resolution (e.g., 100 m for Landsat 8) than surface reflectance (SR) data collected from shortwave bands on the same instrument (e.g., 30 m for Landsat). Spatial sharpening of LST data using the higher resolution multi-band SR data provides an important path for improved agricultural monitoring at sub-field scales. A previously developed Data Mining Sharpener (DMS) approach has shown great potential in the sharpening of Landsat LST using Landsat SR data co-collected over various landscapes. This work evaluates DMS performance for sharpening ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS) LST (~70 m native resolution) and Visible Infrared Imaging Radiometer Suite (VIIRS) LST (375 m) data using Harmonized Landsat and Sentinel-2 (HLS) SR data, providing the basis for generating 30-m LST data at a higher temporal frequency than afforded by Landsat alone. To account for the misalignment between ECOSTRESS/VIIRS and Landsat/HLS caused by errors in registration and orthorectification, we propose a modified version of the DMS approach that employs a relaxed box size for energy conservation (EC). Sharpening experiments were conducted over three study sites in California, and results were evaluated visually and quantitatively against LST data from unmanned aerial vehicles (UAV) flights and from Landsat 8. Over the three sites, the modified DMS technique showed improved sharpening accuracy over the standard DMS for both ECOSTRESS and VIIRS, suggesting the effectiveness of relaxing EC box in relieving misalignment-induced errors. To achieve reasonable accuracy while minimizing loss of spatial detail due to the EC box size increase, an optimal EC box size of 180–270 m was identified for ECOSTRESS and about 780 m for VIIRS data based on experiments from the three sites. Results from this work will facilitate the development of a prototype system that generates high spatiotemporal resolution LST products for improved agricultural water use monitoring by synthesizing multi-source remote sensing data
    corecore