204 research outputs found
Extracting the depolarization coefficient D_NN from data measured with a full acceptance detector
The spin transfer from vertically polarized beam protons to Lambda or Sigma
hyperons of the associated strangeness production pp -> pK Lambda (Sigma) is
described with the depolarization coefficient D_NN. As the polarization of the
hyperons is determined by their weak decays, detectors, which have a large
acceptance for the decay particles, are needed. In this paper a formula is
derived, which describes the depolarization coefficient D_NN by count rates of
a 4 pi detector. It is shown, that formulas, which are given in publications
for detectors with restricted acceptance, are specific cases of this formula
for a 4 pi detector.Comment: Accepted for publication by Nuclear Instruments and Methods in
Physics Research Section
The innovative design of the PANDA Barrel DIRC
The Barrel DIRC of the PANDA experiment at FAIR will cleanly separate pions from kaons for the physics program of PANDA. Innovative solutions for key components of the detector sitting in the strong magnetic field of the compact PANDA target spectrometer as well as two reconstruction methods were developed in an extensive prototype program. The technical design and present results from the test beam campaigns at the CERN PS in 2017 and 2018 are discussed
The Endcap Disc DIRC for PANDA at FAIR
The Endcap Disc DIRC for the PANDA experiment is going to provide an excellent particle identification up to particle momenta of 4 GeV/c. It covers the polar angles from 5◦ to 22◦ and guarantees a separation power of more than 3
standard deviations (s.d.) for pions and kaons in the required phase space. The simulated detector performance has been validated during several testbeam campaigns.
Additionally, the transmission losses of the optical filter has been investigated to estimate the filter performance at the end of the PANDA lifetime
High precision measurement of the associated strangeness production in proton proton interactions
A new high precision measurement of the reaction pp -> pK+Lambda at a beam
momentum of 2.95 GeV/c with more than 200,000 analyzed events allows a detailed
analysis of differential observables and their inter-dependencies. Correlations
of the angular distributions with momenta are examined. The invariant mass
distributions are compared for different regions in the Dalitz plots. The cusp
structure at the N Sigma threshold is described with the Flatt\'e formalism and
its variation in the Dalitz plot is analyzed.Comment: accepted for publication in Eur. Phys. J.
First Model-Independent Measurement of the Spin Triplet Scattering Length from Final State Interaction in the Reaction
The reaction has been measured with the
COSY-TOF detector at a beam momentum of . The polarized
proton beam enables the measurement of the beam analyzing power by the
asymmetry of the produced kaon (). This observable allows the
spin triplet scattering length to be extracted for the first time
model independently from the final-state interaction in the reaction. The
obtained value is . This value is
compatible with theoretical predictions and results from model-dependent
analyses.Comment: Revised version as accepted for publication in PR
Status of the PANDA barrel DIRC
The PANDA experiment at the future Facility for Antiproton and Ion Research in Europe GmbH (FAIR) at GSI, Darmstadt will study fundamental questions of hadron physics and QCD using high-intensity cooled antiproton beams with momenta between 1.5 and 15 GeV/c. Hadronic PID in the barrel region of the PANDA detector will be provided by a DIRC (Detection of Internally Reflected Cherenkov light) counter. The design is based on the successful BABAR DIRC with several key improvements, such as fast photon timing and a compact imaging region. Detailed Monte Carlo simulation studies were performed for DIRC designs based on narrow bars or wide plates with a variety of focusing solutions. The performance of each design was characterized in terms of photon yield and single photon Cherenkov angle resolution and a maximum likelihood approach was used to determine the π/K separation. Selected design options were implemented in prototypes and tested with hadronic particle beams at GSI and CERN. This article describes the status of the design and R&D for the PANDA Barrel DIRC detector, with a focus on the performance of different DIRC designs in simulation and particle beams
- …