4,454 research outputs found

    One-dimensional two-phase reacting gas nonequilibrium performance program Interim analysis report

    Get PDF
    Computer program for calculating inviscid one-dimensional equilibrium, frozen and nonequilibrium nozzle expansion of propellant exhaust mixture

    Using airborne LiDAR Survey to explore historic-era archaeological landscapes of Montserrat in the eastern Caribbean

    Get PDF
    This article describes what appears to be the first archaeological application of airborne LiDAR survey to historic-era landscapes in the Caribbean archipelago, on the island of Montserrat. LiDAR is proving invaluable in extending the reach of traditional pedestrian survey into less favorable areas, such as those covered by dense neotropical forest and by ashfall from the past two decades of active eruptions by the Soufrière Hills volcano, and to sites in localities that are inaccessible on account of volcanic dangers. Emphasis is placed on two aspects of the research: first, the importance of ongoing, real-time interaction between the LiDAR analyst and the archaeological team in the field; and second, the advantages of exploiting the full potential of the three-dimensional LiDAR point cloud data for purposes of the visualization of archaeological sites and features

    Simultaneous in vivo positron emission tomography and magnetic resonance imaging

    Get PDF
    Positron emission tomography (PET) and magnetic resonance imaging (MRI) are widely used in vivo imaging technologies with both clinical and biomedical research applications. The strengths of MRI include high-resolution, high-contrast morphologic imaging of soft tissues; the ability to image physiologic parameters such as diffusion and changes in oxygenation level resulting from neuronal stimulation; and the measurement of metabolites using chemical shift imaging. PET images the distribution of biologically targeted radiotracers with high sensitivity, but images generally lack anatomic context and are of lower spatial resolution. Integration of these technologies permits the acquisition of temporally correlated data showing the distribution of PET radiotracers and MRI contrast agents or MR-detectable metabolites, with registration to the underlying anatomy. An MRI-compatible PET scanner has been built for biomedical research applications that allows data from both modalities to be acquired simultaneously. Experiments demonstrate no effect of the MRI system on the spatial resolution of the PET system and <10% reduction in the fraction of radioactive decay events detected by the PET scanner inside the MRI. The signal-to-noise ratio and uniformity of the MR images, with the exception of one particular pulse sequence, were little affected by the presence of the PET scanner. In vivo simultaneous PET and MRI studies were performed in mice. Proof-of-principle in vivo MR spectroscopy and functional MRI experiments were also demonstrated with the combined scanner

    The Limitations of Block’s ‘Overflow’ Argument With Respect to the Possibility of the Study of Consciousness

    Get PDF
    Block argues for a distinction between phenomenal consciousness [PC] and access consciousness [AC] on the basis of his ‘overflow’ argument. Some have thought that this distinction might limit the possibilities of studying consciousness, as it suggests the existence of conscious mental states whose contents can’t be reported. After distinguishing theoretically between PC and AC, I will summarise Block’s overflow argument for their factual distinction. Highlighting that Block makes two related but separate modal claims about the PC/AC distinction, I will show that the arguments he offers at most support the weak claim that a subject S can have a mental state which is P-conscious but which isn’t A-conscious. But the assumptions on which his argument for the weak claim rest prevent any supporters of his argument from making the strong claim that an individual can have a mental state which is P-conscious but which can’t be A-conscious. And if the overflow argument can’t motivate this stronger claim then there’s no reason to think that any mental state which is P-conscious can’t be made A-conscious given the right circumstances. In which case, even if Block’s argument succeeds, there’s no reason to think that there are inherently inaccessible and thus unreportable conscious mental states. So fears about the limitations of the possibility of the study of consciousness due to the existence of such mental states on the basis of the overflow argument can be allayed

    Cherenkov luminescence measurements with digital silicon photomultipliers: a feasibility study.

    Get PDF
    BackgroundA feasibility study was done to assess the capability of digital silicon photomultipliers to measure the Cherenkov luminescence emitted by a β source. Cherenkov luminescence imaging (CLI) is possible with a charge coupled device (CCD) based technology, but a stand-alone technique for quantitative activity measurements based on Cherenkov luminescence has not yet been developed. Silicon photomultipliers (SiPMs) are photon counting devices with a fast impulse response and can potentially be used to quantify β-emitting radiotracer distributions by CLI.MethodsIn this study, a Philips digital photon counting (PDPC) silicon photomultiplier detector was evaluated for measuring Cherenkov luminescence. The PDPC detector is a matrix of avalanche photodiodes, which were read one at a time in a dark count map (DCM) measurement mode (much like a CCD). This reduces the device active area but allows the information from a single avalanche photodiode to be preserved, which is not possible with analog SiPMs. An algorithm to reject the noisiest photodiodes and to correct the measured count rate for the dark current was developed.ResultsThe results show that, in DCM mode and at (10-13) °C, the PDPC has a dynamic response to different levels of Cherenkov luminescence emitted by a β source and transmitted through an opaque medium. This suggests the potential for this approach to provide quantitative activity measurements. Interestingly, the potential use of the PDPC in DCM mode for direct imaging of Cherenkov luminescence, as a opposed to a scalar measurement device, was also apparent.ConclusionsWe showed that a PDPC tile in DCM mode is able to detect and image a β source through its Cherenkov radiation emission. The detector's dynamic response to different levels of radiation suggests its potential quantitative capabilities, and the DCM mode allows imaging with a better spatial resolution than the conventional event-triggered mode. Finally, the same acquisition procedure and data processing could be employed also for other low light levels applications, such as bioluminescence

    Thermal detection of single e-h pairs in a biased silicon crystal detector

    Get PDF
    We demonstrate that individual electron-hole pairs are resolved in a 1 cm2^2 by 4 mm thick silicon crystal (0.93 g) operated at ∼\sim35 mK. One side of the detector is patterned with two quasiparticle-trap-assisted electro-thermal-feedback transition edge sensor (QET) arrays held near ground potential. The other side contains a bias grid with 20\% coverage. Bias potentials up to ±\pm 160 V were used in the work reported here. A fiber optic provides 650~nm (1.9 eV) photons that each produce an electron-hole (e−h+e^{-} h^{+}) pair in the crystal near the grid. The energy of the drifting charges is measured with a phonon sensor noise σ\sigma ∼\sim0.09 e−h+e^{-} h^{+} pair. The observed charge quantization is nearly identical for h+h^+'s or e−e^-'s transported across the crystal.Comment: 4 journal pages, 5 figure

    Factors influencing the choice of shared bicycles and shared electric bikes in Beijing

    Get PDF
    AbstractChina leads the world in both public bikeshare and private electric bike (e-bike) growth. Current trajectories indicate the viability of deploying large-scale shared e-bike (e-bikeshare) systems in China. We employ a stated preference survey and multinomial logit to model the factors influencing the choice to switch from an existing transportation mode to bikeshare or e-bikeshare in Beijing. Demand is influenced by distinct sets of factors: the bikeshare choice is most sensitive to measures of effort and comfort while the e-bikeshare choice is more sensitive to user heterogeneities. Bikeshare demand is strongly negatively impacted by trip distance, temperature, precipitation, and poor air quality. User demographics however do not factor strongly on the bikeshare choice, indicating the mode will draw users from across the social spectrum. The e-bikeshare choice is much more tolerant of trip distance, high temperatures and poor air quality, though precipitation is also a highly negative factor. User demographics do play a significant role in e-bikeshare demand. Analysis of impact to the existing transportation system finds that both bikeshare and e-bikeshare will tend to draw users away from the “unsheltered modes”, walk, bike, and e-bike. Although it is unclear if shared bikes are an attractive “first-and-last-mile solution”, it is clear that e-bikeshare is attractive as a bus replacement
    • …
    corecore