223 research outputs found

    Transient Thermo-Mechanical Analysis of the TPSG4 Beam Diluter

    Get PDF
    A new extraction channel is being built in the Super Proton Synchrotron (SPS) Long Straight Section 4 (LSS4) to transfer proton beams to the Large Hadron Collider (LHC) and also to the CERN Neutrino to Gran Sasso (CNGS) target. The beam is extracted in a fast mode during a single turn. For this purpose a protection of the MSE copper septum coil, in the form of a beam diluting element placed upstream, will be required to cope with the new failure modes associated with the fast extraction operation. The present analysis focuses on the thermo-mechanical behavior of the proposed TPSG4 diluter element irradiated by a fast extracted beam (up to 4.9 x 10^13 protons per 7.2 mus pulse) from the SPS. The deposited energy densities, estimated from primary and secondary particle simulations using the high-energy particle transport code FLUKA, were converted to internal heat generation rates taken as a thermal load input for the finite-element engineering analyses code ANSYS. According to the time dependence of the extracted beam, the transient solutions were obtained for coupled heat transfer, structural deformation, and shock wave problems. The results are given for the space distribution and the time evolution of temperatures and stresses in the most critical parts of the TPSG4 beam diluting element followed by the MSE copper septum coil. In the worst case of impact of the full LHC ultimate beam, the maximum temperatures remain safely below the melting point. However, the maximum equivalent stresses may slightly exceed the elastic limit in the aluminium section of the diluter. Also, the predicted maximum temperature rise in the MSE septum coil exceeds the design value

    Reducing the SPS Machine Impedance

    Get PDF
    The SPS as LHC Injector project has been working for some time to prepare the SPS for its role as final injector for the LHC. This included major work related to injection, acceleration, extraction and beam instrumentation for the LHC beams [1]. Measurements carried out with the high brightness LHC beam showed that a major improvement of the machine impedance would also be necessary [2]. In addition to removing all lepton related components (once LEP operation ended in 2000), the decision was made to shield the vacuum system pumping port cavities. These accidental cavities had been identified as having characteristic frequencies in the 1-1.5GHz range. Since the SPS vacuum system contains roughly 1000 of these cavities, they constitute a major fraction of the machine impedance. As removal of the ports and associated bellows is not possible, transition shields (PPS) had to be designed to insert within the pumping port cavities

    A dimensionally continued Poisson summation formula

    Full text link
    We generalize the standard Poisson summation formula for lattices so that it operates on the level of theta series, allowing us to introduce noninteger dimension parameters (using the dimensionally continued Fourier transform). When combined with one of the proofs of the Jacobi imaginary transformation of theta functions that does not use the Poisson summation formula, our proof of this generalized Poisson summation formula also provides a new proof of the standard Poisson summation formula for dimensions greater than 2 (with appropriate hypotheses on the function being summed). In general, our methods work to establish the (Voronoi) summation formulae associated with functions satisfying (modular) transformations of the Jacobi imaginary type by means of a density argument (as opposed to the usual Mellin transform approach). In particular, we construct a family of generalized theta series from Jacobi theta functions from which these summation formulae can be obtained. This family contains several families of modular forms, but is significantly more general than any of them. Our result also relaxes several of the hypotheses in the standard statements of these summation formulae. The density result we prove for Gaussians in the Schwartz space may be of independent interest.Comment: 12 pages, version accepted by JFAA, with various additions and improvement

    Preliminary Report on the Consequences of LHC Civil Engineering for the SPS and LEP

    Get PDF
    The excavation of the shafts and caverns for the ATLAS and CMS experiments of the LHC will start whilst LEP and the SPS are running. This will be at a period when LEP should be at its peak performance and the SPS will be providing beams for LEP, fixed target physics and LHC test beams. Simulations show that movements of the machine tunnels can be expected during the excavation and it is essential that this does not affect the performance of the SPS and LEP. These movements are of sufficient amplitude to prevent machine operation if no precautions are taken. This preliminary report outlines the problems and suggests what actions should be taken to ensure efficient operation of the SPS and LEP during the critical period

    Introducing the DizzyQuest: an app-based diary for vestibular disorders

    Get PDF
    BACKGROUND Most questionnaires currently used for assessing symptomatology of vestibular disorders are retrospective, inducing recall bias and lowering ecological validity. An app-based diary, administered multiple times in daily life, could increase the accuracy and ecological validity of symptom measurement. The objective of this study was to introduce a new experience sampling method (ESM) based vestibular diary app (DizzyQuest), evaluate response rates, and to provide examples of DizzyQuest outcome measures which can be used in future research. METHODS Sixty-three patients diagnosed with a vestibular disorder were included. The DizzyQuest consisted of four questionnaires. The morning- and evening-questionnaires were administered once each day, the within-day-questionnaire 10 times a day using a semi-random time schedule, and the attack questionnaire could be completed after the occurrence of a vertigo or dizziness attack. Data were collected for 4~weeks. Response rates and loss-to-follow-up were determined. Reported symptoms in the within-day-questionnaire were compared within and between patients and subgroups of patients with different vestibular disorders. RESULTS Fifty-one patients completed the study period. Average response rates were significantly higher than the desired response rate of \textgreater 50% (p \textless 0.001). The attack-questionnaire was used 159 times. A variety of neuro-otological symptoms and different disease profiles were demonstrated between patients and subgroups of patients with different vestibular disorders. CONCLUSION The DizzyQuest is able to capture vestibular symptoms within their psychosocial context in daily life, with little recall bias and high ecological validity. The DizzyQuest reached the desired response rates and showed different disease profiles between subgroups of patients with different vestibular disorders. This is the first time ESM was used to assess daily symptoms and quality of life in vestibular disorders, showing that it might be a useful tool in this population

    Modification of the LEP electrostatic separator systems for operation with bunch trains

    Get PDF
    To meet the LEP2 luminosity requirements for W-pair production, it is planned to operate LEP with Bunch Trains from 1995 onwards. This new mode of operation entails significant modification both to the existing separator hardware and its control system. The changes have been implemented so as to provide maximum flexibility for the realisation of the Bunch Train scheme, and also make a return to operation with Pretzel separation possible during 1995. Two LEP Interaction Points (IP) were equipped with new separators in late 1994, enabling first tests with the collision of one train of four e+ bunches with one train of e- bunches. During the 1994/95 shutdown, four separators have been installed in the two remaining experimental IPs, and eight separators in the non-experimental IP have been displaced to new positions. Details are given of optics requirements for the separator installations, the polarity of the closed orbit separator bumps, system modifications, and performance considerations. Results are presented of investigations into the effects of separator polarity on High Voltage performance and on the commissioning of the new hardware systems during tests of the Bunch Train scheme in 1994

    Bilateral vestibulopathy and age:experimental considerations for testing dynamic visual acuity on a treadmill

    Get PDF
    Introduction: Bilateral vestibulopathy (BVP) can affect visual acuity in dynamic conditions, like walking. This can be assessed by testing Dynamic Visual Acuity (DVA) on a treadmill at different walking speeds. Apart from BVP, age itself might influence DVA and the ability to complete the test. The objective of this study was to investigate whether DVA tested while walking, and the drop-out rate (the inability to complete all walking speeds of the test) are significantly influenced by age in BVP-patients and healthy subjects. Methods: Forty-four BVP-patients (20 male, mean age 59 years) and 63 healthy subjects (27 male, mean age 46 years) performed the DVA test on a treadmill at 0 (static condition), 2, 4 and 6 km/h (dynamic conditions). The dynamic visual acuity loss was calculated as the difference between visual acuity in the static condition and visual acuity in each walking condition. The dependency of the drop-out rate and dynamic visual acuity loss on BVP and age was investigated at all walking speeds, as well as the dependency of dynamic visual acuity loss on speed. Results: Age and BVP significantly increased the drop-out rate (p ≤ 0.038). A significantly higher dynamic visual acuity loss was found at all speeds in BVP-patients compared to healthy subjects (p < 0.001). Age showed no effect on dynamic visual acuity loss in both groups. In BVP-patients, increasing walking speeds resulted in higher dynamic visual acuity loss (p ≤ 0.036). Conclusion DVA tested while walking on a treadmill, is one of the few “close to reality” functional outcome measures of vestibular function in the vertical plane. It is able to demonstrate significant loss of DVA in bilateral vestibulopathy patients. However, since bilateral vestibulopathy and age significantly increase the drop-out rate at faster walking speeds, it is recommended to use age-matched controls. Furthermore, it could be considered to use an individual “preferred” walking speed and to limit maximum walking speed in older subjects when testing DVA on a treadmill

    The walking speed-dependency of gait variability in bilateral vestibulopathy and its association with clinical tests of vestibular function

    Get PDF
    Understanding balance and gait deficits in vestibulopathy may help improve clinical care and our knowledge of the vestibular contributions to balance. Here, we examined walking speed effects on gait variability in healthy adults and in adults with bilateral vestibulopathy (BVP). Forty-four people with BVP, 12 healthy young adults and 12 healthy older adults walked at 0.4m/s to 1.6m/s in 0.2m/s increments on a dual belt, instrumented treadmill. Using motion capture and kinematic data, the means and coefficients of variation for step length, time, width and double support time were calculated. The BVP group also completed a video head impulse test and examinations of ocular and cervical vestibular evoked myogenic potentials and dynamic visual acuity. Walking speed significantly affected all gait parameters. Step length variability at slower speeds and step width variability at faster speeds were the most distinguishing parameters between the healthy participants and people with BVP, and among people with BVP with different locomotor capacities. Step width variability, specifically, indicated an apparent persistent importance of vestibular function at increasing speeds. Gait variability was not associated with the clinical vestibular tests. Our results indicate that gait variability at multiple walking speeds has potential as an assessment tool for vestibular interventions

    The Functional Head Impulse Test to Assess Oscillopsia in Bilateral Vestibulopathy

    Get PDF
    Introduction: Bilateral vestibulopathy (BV) is a chronic condition in which vestibular function is severely impaired or absent on both ears. Oscillopsia is one of the main symptoms of BV. Oscillopsia can be quantified objectively by functional vestibular tests, and subjectively by questionnaires. Recently, a new technique for testing functionally effective gaze stabilization was developed: the functional Head Impulse Test (fHIT). This study compared the fHIT with the Dynamic Visual Acuity assessed on a treadmill (DVAtreadmill) and Oscillopsia Severity Questionnaire (OSQ) in the context of objectifying the experience of oscillopsia in patients with BV.Methods: Inclusion criteria comprised: (1) summated slow phase velocity of nystagmus of &lt;20°/s during bithermal caloric tests, (2) torsion swing tests gain of &lt;30% and/or phase &lt;168°, and (3) complaints of oscillopsia and/or imbalance. During the fHIT (Beon Solutions srl, Italy) patients were seated in front of a computer screen. During a passive horizontal head impulse a Landolt C optotype was shortly displayed. Patients reported the seen optotype by pressing the corresponding button on a keyboard. The percentage correct answers was registered for leftwards and rightwards head impulses separately. During DVAtreadmill patients were positioned on a treadmill in front of a computer screen that showed Sloan optotypes. Patients were tested in static condition and in dynamic conditions (while walking on the treadmill at 2, 4, and 6 km/h). The decline in LogMAR between static and dynamic conditions was registered for each speed. Every patient completed the Oscillopsia Severity Questionnaire (OSQ).Results: In total 23 patients were included. This study showed a moderate correlation between OSQ outcomes and the fHIT [rightwards head rotations (rs = −0.559; p = 0.006) leftwards head rotations (rs = −0.396; p = 0.061)]. No correlation was found between OSQ outcomes and DVAtreadmill, or between DVAtreadmill and fHIT. All patients completed the fHIT, 52% of the patients completed the DVAtreadmill on all speeds.Conclusion: The fHIT seems to be a feasible test to quantify oscillopsia in BV since, unlike DVAtreadmill, it correlates with the experienced oscillopsia measured by the OSQ, and more BV patients are able to complete the fHIT than DVAtreadmill

    Український фольклорний анекдот як гуманiтарна цiннiсть та гуманiстичний iдеал: перспективи вивчення

    Get PDF
    Кирчiв Р.Ф. Етюди до студій над українським народним анекдотом. Львiв: Інститут народознавства НАН України, 2008. 268 c
    corecore