177 research outputs found

    Exciton gas transport through nano-constrictions

    Get PDF
    An indirect exciton is a bound state of an electron and a hole in spatially separated layers. Two-dimensional indirect excitons can be created optically in heterostructures containing double quantum wells or atomically thin semiconductors. We study theoretically transmission of such bosonic quasiparticles through nano-constrictions. We show that quantum transport phenomena, e.g., conductance quantization, single-slit diffraction, two-slit interference, and the Talbot effect, are experimentally realizable in systems of indirect excitons. We discuss similarities and differences between these phenomena and their counterparts in electronic devices.Comment: (v2) Updated title, text, and references; 12 pages, 9 figure

    Imaging of tumor hypoxia with [124I]IAZA in comparison with [18F]FMISO and [18F]FAZA – first small animal PET results

    Get PDF
    PURPOSE: This study was performed to compare the 2-nitroimidazole derivatives [124I]IAZA, [18F]FAZA and well known [18F]FMISO in visualization of tumor hypoxia in a mouse model of human cancer using small animal PET. METHODS: PET imaging of female Balb/c nude mice bearing A431 tumors on a Phillips Mosaic small animal PET scanner was performed 3 h p.i. for all three tracers. Mice injected with [124I]IAZA were scanned again after 24 h and 48 h. In addition to the mice breathing air, in the case of [18F]FAZA and [124I]IAZA a second group of mice for each tracer was kept in an atmosphere of carbogen gas (5% of CO2 + 95 % of O2; from 1 h before to 3 h after injection) to evaluate the oxygenation dependency on uptake (all experiments n = 4). After the final PET scan animals were sacrificed and biodistribution was studied. RESULTS: Mice injected with [18F]FAZA displayed significantly higher tumor-to background (T/B) ratios (5.19 +/- 0.73) compared to those injected with [18F]FMISO (3.98 +/- 0.66; P lt;0.05)or[124I]IAZA(2.06+/0.26;Plt; 0.05) or [124I]IAZA (2.06 +/- 0.26; P lt; 0.001) 3 h p.i. Carbogen breathing mice showed lower ratios ([18F]FAZA: 4.06 +/- 0.59; [124I]IAZA: 2.02 +/- 0.36). The T/B ratios increased for [124I]IAZA with time (24 h: 3.83 +/- 0.61; 48 h: 4.20 +/- 0.80), but after these late time points the absolute whole body activity was very low, as could be seen from the biodistribution data (< 0.1 %ID/g for each investigated organ) and ratios were still lower than for [18F]FAZA 3 h p.i. Due to de-iodination uptake in thyroid was high. Biodistribution data were in good agreement with the PET results. CONCLUSIONS: [18F]FAZA showed superior biokinetics compared to [18F]FMISO and [124I]IAZA in this study. Imaging at later time points that are not possible with the short lived 18F labeled tracers resulted in no advantage for [124I]IAZA, i. e. tumor to normal tissue ratios could not be improved. © 1999 Canadian Society for Pharmaceutical Sciences

    Indirect excitons in a potential energy landscape created by a perforated electrode

    Get PDF
    We report on the principle and realization of an excitonic device: a ramp that directs the transport of indirect excitons down a potential energy gradient created by a perforated electrode at a constant voltage. The device provides an experimental proof of principle for controlling exciton transport with electrode density gradients. We observed that the exciton transport distance along the ramp increases with increasing exciton density. This effect is explained in terms of disorder screening by repulsive exciton-exciton interactions

    Transference of natural diversity from the apomictic germplasm of Paspalum notatum to a sexual synthetic population

    Get PDF
    Genetic improvement in apomictic forage species has been restricted because of the absence of genetic variability in sexual germplasm with the same ploidy level. Following a new breeding scheme, a sexual synthetic tetraploid population (SSTP) of Paspalum notatum has been generated. The objectives of this work were: (a) to evaluate the genetic variability in SSTP by means of molecular markers, morphologic and agronomic traits, and seed fertility and quality traits and (b) to assess the transference of genetic variability from the apomictic germplasm to the sexual one. Molecular markers revealed a twofold higher level of variability in the SSTP in comparison with the sexual germplasm utilised for its generation, and similar levels with the apomictic ones; moreover, markers showed that most of the variability was inherited from theapomictic germplasm. Morphologic and agronomic traits and seed fertility and quality traits showed high levels of variation in the three groups of genotypes indicating that the new breeding scheme was effective in transferring variability from the apomictic germplasm to the SSTP. This new population will be useful in breeding of P. notatum, and the breeding scheme used for its generation may be used in other apomictic species.Fil: Zilli, Alex Leonel. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Nordeste. Instituto de Botánica del Nordeste. Universidad Nacional del Nordeste. Facultad de Ciencias Agrarias. Instituto de Botánica del Nordeste; ArgentinaFil: Acuña, Carlos Alberto. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Nordeste. Instituto de Botánica del Nordeste. Universidad Nacional del Nordeste. Facultad de Ciencias Agrarias. Instituto de Botánica del Nordeste; ArgentinaFil: Schulz, Roberto R.. Universidad Nacional del Nordeste; ArgentinaFil: Marcón, Florencia. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Nordeste. Instituto de Botánica del Nordeste. Universidad Nacional del Nordeste. Facultad de Ciencias Agrarias. Instituto de Botánica del Nordeste; ArgentinaFil: Brugnoli, Elsa Andrea. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Nordeste. Instituto de Botánica del Nordeste. Universidad Nacional del Nordeste. Facultad de Ciencias Agrarias. Instituto de Botánica del Nordeste; ArgentinaFil: Novo, Sabina F.. Universidad Nacional del Nordeste. Facultad de Ciencias Agrarias; ArgentinaFil: Quarin, Camilo Luis. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Nordeste. Instituto de Botánica del Nordeste. Universidad Nacional del Nordeste. Facultad de Ciencias Agrarias. Instituto de Botánica del Nordeste; ArgentinaFil: Martínez, Eric Javier. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Nordeste. Instituto de Botánica del Nordeste. Universidad Nacional del Nordeste. Facultad de Ciencias Agrarias. Instituto de Botánica del Nordeste; Argentin

    Tumor volume in subcutaneous mouse xenografts measured by microCT is more accurate and reproducible than determined by 18F-FDG-microPET or external caliper

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In animal studies tumor size is used to assess responses to anticancer therapy. Current standard for volumetric measurement of xenografted tumors is by external caliper, a method often affected by error. The aim of the present study was to evaluate if microCT gives more accurate and reproducible measures of tumor size in mice compared with caliper measurements. Furthermore, we evaluated the accuracy of tumor volume determined from <sup>18</sup>F-fluorodeoxyglucose (<sup>18</sup>F-FDG) PET.</p> <p>Methods</p> <p>Subcutaneously implanted human breast adenocarcinoma cells in NMRI nude mice served as tumor model. Tumor volume (n = 20) was determined <it>in vivo </it>by external caliper, microCT and <sup>18</sup>F-FDG-PET and subsequently reference volume was determined <it>ex vivo</it>. Intra-observer reproducibility of the microCT and caliper methods were determined by acquiring 10 repeated volume measurements. Volumes of a group of tumors (n = 10) were determined independently by two observers to assess inter-observer variation.</p> <p>Results</p> <p>Tumor volume measured by microCT, PET and caliper all correlated with reference volume. No significant bias of microCT measurements compared with the reference was found, whereas both PET and caliper had systematic bias compared to reference volume. Coefficients of variation for intra-observer variation were 7% and 14% for microCT and caliper measurements, respectively. Regression coefficients between observers were 0.97 for microCT and 0.91 for caliper measurements.</p> <p>Conclusion</p> <p>MicroCT was more accurate than both caliper and <sup>18</sup>F-FDG-PET for <it>in vivo </it>volumetric measurements of subcutaneous tumors in mice.<sup>18</sup>F-FDG-PET was considered unsuitable for determination of tumor size. External caliper were inaccurate and encumbered with a significant and size dependent bias. MicroCT was also the most reproducible of the methods.</p

    Mesh management methods in finite element simulations of orthodontic tooth movement

    Get PDF
    In finite element simulations of orthodontic tooth movement, one of the challenges is to represent long term tooth movement. Large deformation of the periodontal ligament and large tooth displacement due to bone remodelling lead to large distortions of the finite element mesh when a Lagrangian formalism is used. We propose in this work to use an Arbitrary Lagrangian Eulerian (ALE) formalism to delay remeshing operations. A large tooth displacement is obtained including effect of remodelling without the need of remeshing steps but keeping a good-quality mesh. Very large deformations in soft tissues such as the periodontal ligament is obtained using a combination of the ALE formalism used continuously and a remeshing algorithm used when needed. This work demonstrates that the ALE formalism is a very efficient way to delay remeshing operations
    corecore