100 research outputs found

    175 GHz, 400-fs-pulse harmonically mode-locked surface emitting semiconductor laser

    No full text
    We report a harmonically mode-locked vertical external cavity surface emitting laser (VECSEL) producing 400 fs pulses at a repetition frequency of 175 GHz with an average output power of 300 mW. Harmonic mode-locking was established using a 300 µm thick intracavity single crystal diamond heat spreader in thermal contact with the front surface of the gain sample using liquid capillary bonding. The repetition frequency was set by the diamond microcavity and stable harmonic mode locking was achieved when the laser cavity length was tuned so that the laser operated on the 117th harmonic of the fundamental cavity. When an etalon placed intracavity next to the gain sample, but not in thermal contact was used pulse groups were observed. These contained 300 fs pulses with a spacing of 5.9 ps. We conclude that to achieve stable harmonic mode locking at repetition frequencies in the 100s of GHz range in a VECSEL there is a threshold pulse energy above which harmonic mode locking is achieved and below which groups of pulses are observed

    Do diagnostic delays in cancer matter?

    Get PDF
    background: The United Kingdom has poorer cancer outcomes than many other countries due partly to delays in diagnosing symptomatic cancer, leading to more advanced stage at diagnosis. Delays can occur at the level of patients, primary care, systems and secondary care. There is considerable potential for interventions to minimise delays and lead to earlier-stage diagnosis. methods: Scoping review of the published studies, with a focus on methodological issues. results: Trial data in this area are lacking and observational studies often show no association or negative ones. This review offers methodological explanations for these counter-intuitive findings. conclusion: While diagnostic delays do matter, their importance is uncertain and must be determined through more sophisticated methods

    Pt and CoB trilayer Josephson π junctions with perpendicular magnetic anisotropy

    Get PDF
    We report on the electrical transport properties of Nb based Josephson junctions with Pt/Co68B32/Pt ferromagnetic barriers. The barriers exhibit perpendicular magnetic anisotropy, which has the main advantage for potential applications over magnetisation in-plane systems of not affecting the Fraunhofer response of the junction. In addition, we report that there is no magnetic dead layer at the Pt/Co68B32 interfaces, allowing us to study barriers with ultra-thin Co68B32. In the junctions, we observe that the magnitude of the critical current oscillates with increasing thickness of the Co68B32 strong ferromagnetic alloy layer. The oscillations are attributed to the ground state phase difference across the junctions being modified from zero to π. The multiple oscillations in the thickness range 0.2 ⩽ dCoB ⩽ 1.4 nm suggests that we have access to the first zero-π and π-zero phase transitions. Our results fuel the development of low-temperature memory devices based on ferromagnetic Josephson junctions
    • …
    corecore