267 research outputs found

    Finding faint HI structure in and around galaxies: scraping the barrel

    Get PDF
    Soon to be operational HI survey instruments such as APERTIF and ASKAP will produce large datasets. These surveys will provide information about the HI in and around hundreds of galaxies with a typical signal-to-noise ratio of ∌\sim 10 in the inner regions and ∌\sim 1 in the outer regions. In addition, such surveys will make it possible to probe faint HI structures, typically located in the vicinity of galaxies, such as extra-planar-gas, tails and filaments. These structures are crucial for understanding galaxy evolution, particularly when they are studied in relation to the local environment. Our aim is to find optimized kernels for the discovery of faint and morphologically complex HI structures. Therefore, using HI data from a variety of galaxies, we explore state-of-the-art filtering algorithms. We show that the intensity-driven gradient filter, due to its adaptive characteristics, is the optimal choice. In fact, this filter requires only minimal tuning of the input parameters to enhance the signal-to-noise ratio of faint components. In addition, it does not degrade the resolution of the high signal-to-noise component of a source. The filtering process must be fast and be embedded in an interactive visualization tool in order to support fast inspection of a large number of sources. To achieve such interactive exploration, we implemented a multi-core CPU (OpenMP) and a GPU (OpenGL) version of this filter in a 3D visualization environment (SlicerAstro\tt{SlicerAstro}).Comment: 17 pages, 9 figures, 4 tables. Astronomy and Computing, accepte

    3-D interactive visualisation tools for HI spectral line imaging

    Get PDF
    Upcoming HI surveys will deliver such large datasets that automated processing using the full 3-D information to find and characterize HI objects is unavoidable. Full 3-D visualization is an essential tool for enabling qualitative and quantitative inspection and analysis of the 3-D data, which is often complex in nature. Here we present SlicerAstro\tt{SlicerAstro}, an open-source extension of 3DSlicer, a multi-platform open source software package for visualization and medical image processing, which we developed for the inspection and analysis of HI spectral line data. We describe its initial capabilities, including 3-D filtering, 3-D selection and comparative modelling

    SlicerAstro: a 3-D interactive visual analytics tool for HI data

    Get PDF
    SKA precursors are capable of detecting hundreds of galaxies in HI in a single 12 hours pointing. In deeper surveys one will probe more easily faint HI structures, typically located in the vicinity of galaxies, such as tails, filaments, and extraplanar gas. The importance of interactive visualization has proven to be fundamental for the exploration of such data as it helps users to receive immediate feedback when manipulating the data. We have developed SlicerAstro, a 3-D interactive viewer with new analysis capabilities, based on traditional 2-D input/output hardware. These capabilities enhance the data inspection, allowing faster analysis of complex sources than with traditional tools. SlicerAstro is an open-source extension of 3DSlicer, a multi-platform open source software package for visualization and medical image processing. We demonstrate the capabilities of the current stable binary release of SlicerAstro, which offers the following features: i) handling of FITS files and astronomical coordinate systems; ii) coupled 2-D/3-D visualization; iii) interactive filtering; iv) interactive 3-D masking; v) and interactive 3-D modeling. In addition, SlicerAstro has been designed with a strong, stable and modular C++ core, and its classes are also accessible via Python scripting, allowing great flexibility for user-customized visualization and analysis tasks.Comment: 18 pages, 11 figures, Accepted by Astronomy and Computing. SlicerAstro link: https://github.com/Punzo/SlicerAstro/wiki#get-slicerastr

    On the stability of solutions of semilinear elliptic equations with Robin boundary conditions on Riemannian manifolds

    Full text link
    We investigate existence and nonexistence of stationary stable nonconstant solutions, i.e. patterns, of semilinear parabolic problems in bounded domains of Riemannian manifolds satisfying Robin boundary conditions. These problems arise in several models in applications, in particular in Mathematical Biology. We point out the role both of the nonlinearity and of geometric objects such as the Ricci curvature of the manifold, the second fundamental form of the boundary of the domain and its mean curvature. Special attention is devoted to surfaces of revolution and to spherically symmetric manifolds, where we prove refined results

    Physics-augmented models to simulate commercial adaptive cruise control (ACC) systems

    Get PDF
    This paper investigates the accuracy and robustness of car-following (CF) and adaptive cruise control (ACC) models in reproducing measured trajectories of commercial ACCs. To this aim, a general modelling framework is proposed, in which ACC and CF models have been incrementally augmented with physics-based extensions: namely, perception delay, linear or nonlinear vehicle dynamics, and acceleration constraints. This framework has been applied to the Intelligent Driver Model (IDM), Gipps’ model, and to three basic ACC algorithms. These are linear controllers which are coupled with a constant time-headway spacing policy, and with two other policies derived from the traffic flow theory: the IDM desired distance function, and Gipps’ equilibrium distance-speed function. The ninety models resulting from the combination of the five base models with the aforementioned extensions, have been assessed and compared through a vast calibration and validation experiment against measured trajectory data of vehicles driven by ACC systems. Overall, the study has shown that physics-based extensions provide limited improvements to the accuracy of existing models. In addition, if an investigation against measured data is not carried out, it is not possible to argue which extension is the most suited for a specific model. The linear controller with Gipps’ spacing policy has resulted the most accurate model, while the IDM the most robust to different input trajectories. Eventually, all models have failed to capture the behaviour of some car brands – just as models fail with some human drivers. Therefore, the choice of the “best” model is independent of the car brand to simulate

    Narrative review of cardiac computed tomography perfusion: insights into static rest perfusion

    Get PDF
    Cardiac or left ventricular perfusion performed with cardiac computed tomography (CCT) is a developing method that may have the potential to complete in a very straight forward way the assessment of ischemic heart disease by means of CT. Myocardial CT perfusion (CTP) can be achieved with a single static scan during the first-pass of the iodinate contrast agent, with the monoenergetic or dual-energy acquisition, or as a dynamic, time-resolved scan during stress by using coronary vasodilator agents. Several methods can be performed, and we focused on static perfusion. CTP may serve as a useful adjunct to coronary CT angiography (CTA) to improve specificity of detecting myocardial ischemia. Technological advances will reduce the radiation dose of myocardial CTP, such as low tube voltage imaging or new reconstruction algorithms, making it a more viable clinical option. The advantages of static first-pass non-stress perfusion are several; the main one is that it can be done to each and every patient who undergoes CCT for the assessment of coronary artery tree. Future advances in CTP will likely improve the diagnostic accuracy of CTP + CTA, and will better estimate the severity of ischemia Therefore, it is simple and comprehensive. However, it has several limitations. In this review we will discuss the technique with its advantages and limitations

    Coronary atherosclerosis as the main endpoint of non-invasive imaging in cardiology: A narrative review

    Get PDF
    The change of paradigm determined by the introduction of cardiac computed tomography (CCT) in the field of cardiovascular medicine has allowed new evidence to emerge. These evidences point towards a major role, probably the most important one in terms of prognostic impact, in the detection, characterization and quantification of atherosclerosis as the main driver and endpoint for the management of coronary artery disease (CAD). Extensive literature has been published in the last decade with large numbers and patients’ populations, investigating several aspects and correlations between atherosclerotic plaque features and risk factors; also, the relationship between plaque features, both with qualitative and quantitative approaches, and cardiovascular events has been investigated. More recent studies have also pointed out the relationship between the knowledge and classification of sub-clinical atherosclerosis and the induced modification of medical therapy (both aggressiveness and compliance) that is most likely able to increase the effect of anti-atherosclerotic drugs, hence significantly improving prognosis. Non-invasive assessment of CAD by means of CCT is becoming the primary tool for management and also the most important parameter for the comprehension of natural history of CAD and how the therapies we adopt are affecting plaque burden as a whole. In this review we will address the modern concepts of CAD driven understanding and management of cardiovascular disease

    Insight from imaging on plaque vulnerability: similarities and differences between coronary and carotid arteries—implications for systemic therapies

    Get PDF
    Nowadays it is widely accepted that the rupture of the atherosclerotic plaque in coronary and carotid arteries plays a fundamental role in the development of acute myocardial infarctions or cerebrovascular events. In recent years, imaging techniques have explored, with a new level of detail, the atherosclerotic disease generating new evidences that some plaque characteristics are significantly associated to the risk of rupture and subsequent thrombosis or embolization. Moreover, the recent evidence of the anti-atherosclerotic effects determined by lipid-lowering and anti-inflammatory therapies poses a challenge for the choice of therapeutic approaches (best/optimal medical therapy vs. revascularization), maximized by the evidence that coronary and carotid atherosclerosis share common patterns but also differ regarding some important features. In this Review, we discuss the similarities and differences between coronary and carotid artery vulnerable plaque from the imaging point of view and the potential implications for systemic therapies according to the emerging evidence
    • 

    corecore