7 research outputs found

    The 2nd Baltic Osseointegration Academy and Lithuanian University of Health Sciences Consensus Conference 2019. Summary and consensus statements: Group II - Extraction socket preservation methods and dental implant placement outcomes within grafted sockets

    Get PDF
    Introduction: The task of Group II was to review and update the existing data concerning extraction socket preservation with or without membranes and soft tissue influence on post-extraction alveolar ridge preservation; extraction socket preservation using different biomaterials as bone grafts, growth factors, and stem cells. Special interest was paid to the dental implant placement outcomes within grafted sockets.Material and Methods: The main areas evaluated by this group were as follows: quantitative and qualitative assessment of the effect of different alveolar preservation techniques performed immediately after tooth extraction, with or without membranes and/or soft tissue grafting, and the use of different bone substitutes, stem cells or growth factors in the postextraction socket. Evaluation of the treatment outcomes of dental implants placed in the grafted sockets in terms of primary and secondary outcomes were assessed. The systematic reviews and/or meta-analyses were registered in PROSPERO, an international prospective register of systematic reviews: http://www.crd.york.ac.uk/PROSPERO/. TThe literature in the corresponding areas of interest was screened and reported following the PRISMA guidelines (Preferred Reporting Item for Systematic Review and Meta-Analysis) Statement: http://www.prisma-statement.org/. Method of preparation of the systematic reviews, based on comprehensive search strategies, was discussed and standardized. The summary of the materials and methods employed by the authors in preparing the systematic reviews and/or meta-analyses is presented in the Preface chapter.Results: The results and conclusions of the review process are presented in the respective papers. Three systematic reviews and one systematic review and meta-analysis were performed. The group's general commentaries, consensus statements, clinical recommendations and implications for research are presented in this article.info:eu-repo/semantics/publishedVersio

    Comparison of Selected Anatomical and Treatment-related Diagnostic Parameters Estimated by Cone-Beam Computed Tomography and Digital Periapical Radiography in Teeth with Apical Periodontitis

    No full text
    Objectives: To compare selected anatomical and treatment-related diagnostic parameters estimated by cone-beam computed tomography and by digital periapical radiography in teeth with apical periodontitis, and to evaluate reliability of different examiners in interpretation of images obtained by both methods. Material and Methods: Teeth with apical periodontitis were evaluated independently by 2 endodontists and 1 radiologist based on 128 cone-beam computed tomography (CBCT) and 162 digital periapical radiography (DPR) images. Anatomical (size, relation with root, location of periapical radiolucency) and treatment-related (canal obturation length, homogeneity, coronal seal) parameters were assessed. Fleiss kappa reflected inter-observer agreement while intra-examiner agreement was estimated by Cohen's kappa. McNemar and McNemar-Bowker tests served for evaluation of differences between CBCT- and DPR-based estimates. Results: Cohen's kappa ranged from 0.62 to 1 for all examiners. Fleiss kappa values were nearly perfect for majority of parameters. Diagnostic discrepancy between methods was found for size of radiolucency that in 15 - 17% cases was larger, and in 25 - 28% smaller in DPR than in CBCT images. DPR revealed 20% of root canals scored as non-obturated while in CBCT - obturation present. Canal obturation was rated as homogenous by CBCT, while absent or non-homogenous by DPR, in 17 - 23%, and 11 - 14% of cases, respectively. Radiologist detected more root perforations in CBCT than in DPR images. Conclusions: Good intra- and inter-examiner agreement for anatomical and treatment-related diagnostic parameters was achieved using cone-beam computed tomography and digital periapical radiography methods and demonstrated similar diagnostic capability, although variation regarding root perforations and canal obturation quality was observed

    Contour angle and peri‐implant tissue height: Two interrelated features of the implant supracrestal complex

    No full text
    Abstract Objectives Recent research has suggested the contour of the prosthesis and the vertical height of the peri‐implant mucosa as important parameters that can influence the long term health and stability of the peri‐implant tissue. In particular, overcontouring of the prosthesis has been correlated with an increased risk for peri‐implantitis, while reduced soft tissue height has been associated with marginal bone loss, recession, and other soft tissue complications. Although these two parameters have been investigated as independent in the current literature, clinical experience points toward a close interrelation between transmucosal tissue height and prosthesis contour angle. It is often found that a reduced vertical height of the implant supracrestal complex is the main reason for overcontouring of the prosthesis. At the same time, achieving a favorable contour of 30o or less is not possible unless the clinician has ensured an adequate vertical height of the soft tissue. The purpose of this short communication is to establish the relation between tissue vertical height and prosthesis contour by utilizing a theoretical geometry equation based on the Pythagorean theorem. In doing so, one can use the dimensions of the implant as well as those of the prosthesis at the mucosal margin to calculate the essential vertical height for achieving a favorable prosthesis contour. Conclusions As the treatment plan of the implant supracrestal complex is “top‐down,” in case of deficient vertical height, subcrestal placement of the implant should be considered to achieve a proper prosthesis contour

    Digital Planning Technique for Surgical Guides for Prosthetic Implants before Orthodontic Treatment

    No full text
    Background: The use of digitalization allows clinicians to plan the position of dental implants in orthodontic patients treated with aligners in the beginning of their orthodontic treatment, instead of waiting until the end of orthodontic treatment, integrating implant restorations with orthodontic biomechanics. Aim: The aim of this case report is to describe a digital workflow for aligner treatment supported by implants, in which implants are placed at the beginning of the treatment and support the orthodontic treatment. Materials and Methods: Digital planning for orthodontic treatment with clear aligners and the preparation of surgical guides for implant surgery before orthodontic treatment are used to solve two multidisciplinary cases. Cone-beam computed tomography (CBCT) and virtual dental impressions are used for the virtual planning. Successively, a surgical guide for implant placement and aligners are used in the treatment plan. Results: The digital orthodontic setup with the integration of the root position allows the clinician to plan the position of dental implants on the final occlusion. The placement of the implant before the start of the orthodontic treatment allows the implants to be used as skeletal anchorage, thereby helping the orthodontic biomechanics. Conclusions: This study describes how to perform a digital workflow with orthodontic virtual planning and the design of surgical guides for implant placement. This technique is potentially promising for complex orthodontic cases

    A novel fully tapered, self-cutting tissue-level implant: non-inferiority study in minipigs.

    No full text
    OBJECTIVES To assess the osseointegration and crestal bone level maintenance of a novel fully tapered self-cutting tissue-level implant for immediate placement (test) compared to a clinically established tissue-level implant (control) in moderate bone quality. MATERIALS AND METHODS Test and control implants were compared in 3 groups, i.e., small-, medium-, and large-diameter implants in an edentulous mandibular minipig model with moderate bone quality after 12 weeks of healing. Histometrically derived bone-to-implant contact (BIC) and first bone-to-implant contact (fBIC) were subjected to statistical non-inferiority testing. Maximum insertion torque values in artificial bone were assessed for comparison. RESULTS BIC values for the tests and control implants for all 3 diameters were comparable and non-inferior: small diameter (61.30 ± 10.63% vs. 54.46 ± 18.31%) (p=0.99), medium diameter (60.91 ± 14.42 vs. 54.68 ± 9.16) (p=0.55), and large diameter (45.60 ± 14.67 vs. 52.52 ± 14.76) (p=0.31). fBIC values for test implants were higher and non-inferior compared to control implants in all three groups. Test implants further showed distinctly higher maximum insertion torque values compared to control implants. CONCLUSION The investigated novel tissue-level implant is able to achieve high levels of primary and secondary implant stability under simultaneous preservation of crestal bone levels. This qualifies the studied implant as an attractive candidate for immediate placement in bone of limited quality. CLINICAL RELEVANCE This pilot pre-clinical study investigated a novel tissue-level implant for immediate placement. With the aim of translating the studied prototype into clinical application pre-clinical models, procedures and controls have been chosen with the aim of reflecting its future clinical indication and use

    The 1st Baltic Osseointegration Academy and Lithuanian University of Health Sciences Consensus Conference 2016. Summary and Consensus Statements : Group I - Peri-Implantitis Aetiology, Risk Factors and Pathogenesis

    No full text
    Introduction: The task of Group 1 was to review and update the existing data concerning aetiology, risk factors and pathogenesis of peri-implantitis. Previous history of periodontitis, poor oral hygiene, smoking and presence of general diseases have been considered among the aetiological risk factors for the onset of peri-implant pathologies, while late dental implant failures are commonly associated with peri-implantitis and/or with the application of incorrect biomechanical forces. Special interest was paid to the bone cells dynamics as part of the pathogenesis of peri-implantitis. Material and Methods: The main areas indagated by this group were as follows: in uence of smoking, history of periodontitis and general diseases on peri-implantitis development, bio-mechanics of implant loading and its in uence on peri-implant bone and cellular dynamics related to the pathogenesis of peri-implantitis. The systematic reviews and/or meta- analyses were registered in PROSPERO, an international prospective register of systematic reviews: http://www.crd.york. ac.uk/PROSPERO/. The literature in the corresponding areas of interest was screened and reported following the PRISMA (Preferred Reporting Item for Systematic Review and Meta-Analysis) Statement: http://www.prisma-statement.org/. Method of preparation of the systematic reviews, based on comprehensive search strategies, was discussed and standardized. The summary of the materials and methods employed by the authors in preparing the systematic reviews and/or meta-analyses is presented in Preface chapter. Results: The results and conclusions of the review process are presented in the respective papers. One systematic review with meta-analysis, three systematic reviews and one theoretical analysis were performed. The groupâ€Čs general commentaries, consensus statements, clinical recommendations and implications for research are presented in this article

    The 1st Baltic Osseointegration Academy and Lithuanian University of Health Sciences Consensus Conference 2016. Summary and Consensus Statements : Group I - Peri-Implantitis Aetiology, Risk Factors and Pathogenesis

    No full text
    Introduction: The task of Group 1 was to review and update the existing data concerning aetiology, risk factors and pathogenesis of peri-implantitis. Previous history of periodontitis, poor oral hygiene, smoking and presence of general diseases have been considered among the aetiological risk factors for the onset of peri-implant pathologies, while late dental implant failures are commonly associated with peri-implantitis and/or with the application of incorrect biomechanical forces. Special interest was paid to the bone cells dynamics as part of the pathogenesis of peri-implantitis. Material and Methods: The main areas indagated by this group were as follows: in uence of smoking, history of periodontitis and general diseases on peri-implantitis development, bio-mechanics of implant loading and its in uence on peri-implant bone and cellular dynamics related to the pathogenesis of peri-implantitis. The systematic reviews and/or meta- analyses were registered in PROSPERO, an international prospective register of systematic reviews: http://www.crd.york. ac.uk/PROSPERO/. The literature in the corresponding areas of interest was screened and reported following the PRISMA (Preferred Reporting Item for Systematic Review and Meta-Analysis) Statement: http://www.prisma-statement.org/. Method of preparation of the systematic reviews, based on comprehensive search strategies, was discussed and standardized. The summary of the materials and methods employed by the authors in preparing the systematic reviews and/or meta-analyses is presented in Preface chapter. Results: The results and conclusions of the review process are presented in the respective papers. One systematic review with meta-analysis, three systematic reviews and one theoretical analysis were performed. The groupâ€Čs general commentaries, consensus statements, clinical recommendations and implications for research are presented in this article
    corecore