86 research outputs found

    An Objective Scatter Index Based on Double-Pass Retinal Images of a Point Source to Classify Cataracts

    Get PDF
    PURPOSE: To propose a new objective scatter index (OSI) based in the analysis of double-pass images of a point source to rank and classify cataract patients. This classification scheme is compared with a current subjective system. METHODS: We selected a population including a group of normal young eyes as control and patients diagnosed with cataract (grades NO2, NO3 and NO4) according to the Lens Opacities Classification System (LOCS III). For each eye, we recorded double-pass retinal images of a point source. In each patient, we determined an objective scatter index (OSI) as the ratio of the intensity at an eccentric location in the image and the central part. This index provides information on the relevant forward scatter affecting vision. Since the double-pass retinal images are affected by both ocular aberrations and intraocular scattering, an analysis was performed to show the ranges of contributions of aberrations to the OSI. RESULTS: We used the OSI values to classify each eye according to the degree of scatter. The young normal eyes of the control group had OSI values below 1, while the OSI for subjects in LOCS grade II were around 1 to 2. The use of the objective index showed some of the weakness of subjective classification schemes. In particular, several subjects initially classified independently as grade NO2 or NO3 had similar OSI values, and in some cases even higher than subjects classified as grade NO4. A new classification scheme based in OSI is proposed. CONCLUSIONS: We introduced an objective index based in the analysis of double-pass retinal images to classify cataract patients. The method is robust and fully based in objective measurements; i.e., not depending on subjective decisions. This procedure could be used in combination with standard current methods to improve cataract patient surgery scheduling

    A922 Sequential measurement of 1 hour creatinine clearance (1-CRCL) in critically ill patients at risk of acute kidney injury (AKI)

    Get PDF
    Meeting abstrac

    Large expert-curated database for benchmarking document similarity detection in biomedical literature search

    Get PDF
    Document recommendation systems for locating relevant literature have mostly relied on methods developed a decade ago. This is largely due to the lack of a large offline gold-standard benchmark of relevant documents that cover a variety of research fields such that newly developed literature search techniques can be compared, improved and translated into practice. To overcome this bottleneck, we have established the RElevant LIterature SearcH consortium consisting of more than 1500 scientists from 84 countries, who have collectively annotated the relevance of over 180 000 PubMed-listed articles with regard to their respective seed (input) article/s. The majority of annotations were contributed by highly experienced, original authors of the seed articles. The collected data cover 76% of all unique PubMed Medical Subject Headings descriptors. No systematic biases were observed across different experience levels, research fields or time spent on annotations. More importantly, annotations of the same document pairs contributed by different scientists were highly concordant. We further show that the three representative baseline methods used to generate recommended articles for evaluation (Okapi Best Matching 25, Term Frequency–Inverse Document Frequency and PubMed Related Articles) had similar overall performances. Additionally, we found that these methods each tend to produce distinct collections of recommended articles, suggesting that a hybrid method may be required to completely capture all relevant articles. The established database server located at https://relishdb.ict.griffith.edu.au is freely available for the downloading of annotation data and the blind testing of new methods. We expect that this benchmark will be useful for stimulating the development of new powerful techniques for title and title/abstract-based search engines for relevant articles in biomedical research

    Dose response of the 16p11.2 distal copy number variant on intracranial volume and basal ganglia

    Get PDF
    Carriers of large recurrent copy number variants (CNVs) have a higher risk of developing neurodevelopmental disorders. The 16p11.2 distal CNV predisposes carriers to e.g., autism spectrum disorder and schizophrenia. We compared subcortical brain volumes of 12 16p11.2 distal deletion and 12 duplication carriers to 6882 non-carriers from the large-scale brain Magnetic Resonance Imaging collaboration, ENIGMA-CNV. After stringent CNV calling procedures, and standardized FreeSurfer image analysis, we found negative dose-response associations with copy number on intracranial volume and on regional caudate, pallidum and putamen volumes (ÎČ = −0.71 to −1.37; P < 0.0005). In an independent sample, consistent results were obtained, with significant effects in the pallidum (ÎČ = −0.95, P = 0.0042). The two data sets combined showed significant negative dose-response for the accumbens, caudate, pallidum, putamen and ICV (P = 0.0032, 8.9 × 10⁻⁶, 1.7 × 10⁻âč, 3.5 × 10⁻ÂčÂČ and 1.0 × 10⁻⁎, respectively). Full scale IQ was lower in both deletion and duplication carriers compared to non-carriers. This is the first brain MRI study of the impact of the 16p11.2 distal CNV, and we demonstrate a specific effect on subcortical brain structures, suggesting a neuropathological pattern underlying the neurodevelopmental syndromes

    Selective Enamel Etching: Effect on Marginal Adaptation of Self-Etch LED-Cured Bond Systems in Aged Class I Composite Restorations

    No full text
    The aim of this study was to evaluate the influence of previous enamel etch and light emitting diode (LED) curing on gap formation of self-etch adhesive systems in Class I composite restorations after thermomechanical aging (TMA). Thus, on 192 human molars, a box-shaped Class I cavity was prepared maintaining enamel margins. Self-etch adhesives (Clearfil SE and Clearfil S3) were used to restore the preparation with a microhybrid composite. Before application of the adhesives, half of the teeth were enamel etched for 15 seconds with 37% phosphoric acid; the other half were not etched. For the photoactivation of the adhesives and composite, three light-curing units (LCUs) were used: one polywave (Ultra-Lume LED 5, UL) and two single-peak (FlashLite 1401, FL and Radii-cal, RD) LEDs. After this, epoxy resin replicas of the occlusal surface were made, and the specimens were submitted to TMA. New replicas were made from the aged specimens for marginal adaptation analysis by scanning electron microscopy. Data were submitted to Kruskal-Wallis and Wilcoxon tests (alpha=0.05). Before TMA, when enamel was etched before the application of S3, no gap formation was observed; however, there were gaps at the interface for the other tested conditions, with a statistical difference (p <= 0.05). After TMA, the selective enamel etching previous to the S3 application, regardless of the LCU, promoted higher marginal adaptation compared to the other tested groups (p <= 0.05). Prior to TMA, higher marginal integrity was observed, in comparison with specimens after TMA (p <= 0.05). With regard to Clearfil SE and Clearfil Tri-S cured with FL, no differences of gap formation were found between before and after aging (5.3 +/- 3.8 and 7.4 +/- 7.5, respectively), especially when the Clearfil Tri-S was used in the conventional protocol. When cured with RD or UL and not etched, Clearfil Tri-S presented the higher gap formation. In conclusion, additional enamel etching promoted better marginal integrity for Clearfil Tri-S, showing it to be an efficient technique for Class I composite restorations. The two-step self-etch adhesive was not influenced by selective enamel etching or by the LED-curing unit.37219520

    Influence of the LED curing source and selective enamel etching on dentin bond strength of self-etch adhesives in class I composite restorations

    No full text
    The aim of this study was to evaluate the influence of the LED curing unit and selective enamel etching on dentin microtensile bond strength (mu TBS) for self-etch adhesives in class I composite restorations. On 96 human molars, box-shaped class I cavities were made maintaining enamel margins. Self-etch adhesives (Clearfil SE - CSE and Clearfil S-3 - S3) were used to bond a microhybrid composite. Before adhesive application, half of the teeth were enamel acid-etched and the other half was not. Adhesives and composites were cured with the following light curing units (LCUs): one polywave (UltraLume 5 - UL) and two single-peak (FlashLite 1401 - FL and Radii Cal - RD) LEDs. The specimens were then submitted to thermomechanical aging and longitudinally sectioned to obtain bonded sticks (0.9 mm(2)) to be tested in tension at 0.5 mm/min. The failure mode was then recorded. The mu TBS data were submitted to a three-way ANOVA and Tukey's (alpha = 0.05). For S3, the selective enamel-etching provided lower mu TBS values (20.7 +/- 2.7) compared to the non-etched specimens (26.7 +/- 2.2). UL yielded higher mu TBS values (24.1 +/- 3.2) in comparison to the photoactivation approach with FL (18.8 +/- 3.9) and RD (19.9 +/- 1.8) for CSE. The two-step CSE was not influenced by the enamel etching (p a parts per thousand yenaEuro parts per thousand 0.05). Enamel acid etching in class I composite restorations affects the dentin mu TBS of the one-step self-etch adhesive Clearfil S-3, with no alterations for Clearfil SE bond strength. The polywave LED promoted better bond strength for the two-step adhesive compared to the single-peak ones.2761175118

    Knoop Hardness and Effectiveness of Dual-Cured Luting Systems and Flowable Resin to Bond Leucite-Reinforced Ceramic to Enamel

    No full text
    Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Purpose: The aim of this study was to evaluate the Knoop microhardness and microshear bond strength (MSBS) of dual-cured luting systems and flowable resin bonded to leucite-reinforced ceramics and enamel. Materials and Methods: Eighty bovine incisors were randomly divided into four groups per test (microhardness and microshear; n = 10) according to the bonding procedure: Excite DSC/Variolink, Clearfil SE Bond/Panavia F, Adper Scotchbond Multi-Purpose Plus/RelyX ARC, and Adper Single Bond 2/Filtek Z350 Flow. For the KHN measurement, the cement was applied on the enamel surface and light-cured through a ceramic disk (5 mm diameter x 1.2 mm thick). Five indentations were performed in each specimen and measured at HMV-2. For the microshear test, two cylinders of a leucite-reinforced ceramic (1 mm diameter x 2 mm height) were bonded to the enamel substrate in accordance with the bonding procedures previously established. One cylinder was tested 24 hours after cementation, and the other was subjected to thermocycling (2000 cycles) and then submitted to an MSBS test. The data from the hardness and bond strength tests were subjected to one-and two-way repeated-measures analysis of variance (ANOVA), respectively, and to Tukey's test (alpha = 0.05). Results: Scotchbond/RelyX ARC presented higher values of bond strength, while SingleBond/Z350 Flow showed lower values. The thermocycling promoted a reduction in the bond strength values for all groups. Panavia F presented higher values of KHN, and the flowable resin presented the lowest. RelyX ARC and Variolink presented intermediate values on hardness evaluation. Conclusions: For ceramic cementation, dual-cured resin luting systems promoted more reliable bonding and microhardness values than the flowable resin.2215458Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)FAPESP [2009/08420-3, 2009-08992-7]CNPq [133077/2009-8
    • 