66 research outputs found

    Determination of different forms of aminothiols in red blood cells without washing erythrocytes

    Get PDF
    Detection and quantification of different aminothiols forms (reduced and total) in biological fluids are important for the investigation of oxidative stress-related diseases and cell homeostasis study. The aim of this study was to optimize a HPLC method in order to determine both reduced and total thiol forms in red blood cells (RBC) at low temperature without washing erythrocytes. Analytical recoveries for total and reduced thiols were 91.6-98.5 and 94.9-98.2% respectively. The relative standard deviations intra-assay for total and reduced thiols were 1.14-3.64 and 0.83-2.3% respectively and the relative standard deviations inter-assay for total and reduced thiols were 1.12-3.54 and 0.84-2.03%, respectively. This method allows specific analysis of the aminothiol state inside the RBC, as a model of intracellular metabolism functionin

    Live 3-D stress echo: is beauty also a sign of intelligence?

    Get PDF
    Background: Last generation 3-D live stress echo has potential for adding "beauty" (seductive display) and also "intelligence" (unique quantitative information) to the robust, albeit qualitative, classic 2-D stress echo based on wall motion analysis. Aim: to assess feasibility of 3-D stress echo. Materials and methods: From May 2005, we enrolled 214 consecutive patients (age=64?11 years; 88 females) routinely screened for suspect coronary artery disease with dipyridamole (0.84 mg/kg in 6\u27) stress echo. Transthoracic echocardiography (2D, 3D and coronary flow reserve, CFR, by pulsed Doppler) was performed with commercially available systems (iE33) using phase array probes (1-5 and 3-8 MHz, S5-S8) and a matrix 3D probe for 3D-Live application. Each data set was analyzed with a dedicated software (3DQ, QLab - Advanced Ultrasound Quantification Software - vs. 4.1 and 4.2, Philips Electronics), including 3D volumes and dissynchrony index (DI), considered as the mean value of standard deviation of maximum time to systolic volume variation. Results: Interpretable 2D data were obtained in all pts (100 % feasibility), CFR data on left anterior descending artery in 185 pts (88 %) and 3D data in 151 pts (70 %). In the 48 pts with negative stress echo (for wall motion criteria) by 2D and 3D, 3D-DI decreased (rest=1.3?.8 vs. stress=.99?.54, p<.001): see figure. In patients with normal resting echo and positive stress echo, 3D-DI increased (rest= 4.5?1.9 vs. stress= 8.3?3.2, p<0.01). Last generation live 3D dipyridamole stress echo still suffers a feasibility gap vs. 2D and Doppler-CFR stress echo, but shows potential for adding substantial "beauty" (convincing display) and perhaps some extra-"intelligence" (quantitative support) to classic stress echo

    Stress echo 2020: the international stress echo study in ischemic and non-ischemic heart disease

    Get PDF
    BACKGROUND: Stress echocardiography (SE) has an established role in evidence-based guidelines, but recently its breadth and variety of applications have extended well beyond coronary artery disease (CAD). We lack a prospective research study of SE applications, in and beyond CAD, also considering a variety of signs in addition to regional wall motion abnormalities. METHODS: In a prospective, multicenter, international, observational study design, > 100 certified high-volume SE labs (initially from Italy, Brazil, Hungary, and Serbia) will be networked with an organized system of clinical, laboratory and imaging data collection at the time of physical or pharmacological SE, with structured follow-up information. The study is endorsed by the Italian Society of Cardiovascular Echography and organized in 10 subprojects focusing on: contractile reserve for prediction of cardiac resynchronization or medical therapy response; stress B-lines in heart failure; hypertrophic cardiomyopathy; heart failure with preserved ejection fraction; mitral regurgitation after either transcatheter or surgical aortic valve replacement; outdoor SE in extreme physiology; right ventricular contractile reserve in repaired Tetralogy of Fallot; suspected or initial pulmonary arterial hypertension; coronary flow velocity, left ventricular elastance reserve and B-lines in known or suspected CAD; identification of subclinical familial disease in genotype-positive, phenotype- negative healthy relatives of inherited disease (such as hypertrophic cardiomyopathy). RESULTS: We expect to recruit about 10,000 patients over a 5-year period (2016-2020), with sample sizes ranging from 5,000 for coronary flow velocity/ left ventricular elastance/ B-lines in CAD to around 250 for hypertrophic cardiomyopathy or repaired Tetralogy of Fallot. This data-base will allow to investigate technical questions such as feasibility and reproducibility of various SE parameters and to assess their prognostic value in different clinical scenarios. CONCLUSIONS: The study will create the cultural, informatic and scientific infrastructure connecting high-volume, accredited SE labs, sharing common criteria of indication, execution, reporting and image storage of SE to obtain original safety, feasibility, and outcome data in evidence-poor diagnostic fields, also outside the established core application of SE in CAD based on regional wall motion abnormalities. The study will standardize procedures, validate emerging signs, and integrate the new information with established knowledge, helping to build a next-generation SE lab without inner walls

    Post-exercise contractility, diastolic function, and pressure: Operator-independent sensor-based intelligent monitoring for heart failure telemedicine

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>New sensors for intelligent remote monitoring of the heart should be developed. Recently, a cutaneous force-frequency relation recording system has been validated based on heart sound amplitude and timing variations at increasing heart rates.</p> <p>Aim</p> <p>To assess sensor-based post-exercise contractility, diastolic function and pressure in normal and diseased hearts as a model of a wireless telemedicine system.</p> <p>Methods</p> <p>We enrolled 150 patients and 22 controls referred for exercise-stress echocardiography, age 55 ± 18 years. The sensor was attached in the precordial region by an ECG electrode. Stress and recovery contractility were derived by first heart sound amplitude vibration changes; diastolic times were acquired continuously. Systemic pressure changes were quantitatively documented by second heart sound recording.</p> <p>Results</p> <p>Interpretable sensor recordings were obtained in all patients (feasibility = 100%). Post-exercise contractility overshoot (defined as increase > 10% of recovery contractility vs exercise value) was more frequent in patients than controls (27% vs 8%, p < 0.05). At 100 bpm stress heart rate, systolic/diastolic time ratio (normal, < 1) was > 1 in 20 patients and in none of the controls (p < 0.01); at recovery systolic/diastolic ratio was > 1 in only 3 patients (p < 0.01 vs stress). Post-exercise reduced arterial pressure was sensed.</p> <p>Conclusion</p> <p>Post-exercise contractility, diastolic time and pressure changes can be continuously measured by a cutaneous sensor. Heart disease affects not only exercise systolic performance, but also post-exercise recovery, diastolic time intervals and blood pressure changes – in our study, all of these were monitored by a non-invasive wearable sensor.</p

    Significato prognostico del test eco dobutamina nella cardiopatia dilatativa idiopatica

    No full text
    Dottorato di ricerca in fisiopatologia cardiovascolare 11. ciclo. Relatore Mario MarzilliConsiglio Nazionale delle Ricerche - Biblioteca Centrale - P.le Aldo Moro, 7, Rome; Biblioteca Nazionale Centrale - Piazza Cavalleggeri, 1, Florence / CNR - Consiglio Nazionale delle RichercheSIGLEITItal

    Thoraco-abdominal coordination and performance during uphill running at altitude

    Get PDF
    Introduction Running races on mountain trails at moderate-high altitude with large elevation changes throughout has become increasingly popular. During exercise at altitude, ventilatory demands increase due to the combined effects of exercise and hypoxia. Aim To investigate the relationships between thoraco-abdominal coordination, ventilatory pattern, oxygen saturation (SpO2), and endurance performance in runners during high-intensity uphill exercise. Methods Fifteen participants (13 males, mean age 42±9 yrs) ran a “Vertical Kilometer,” i.e., an uphill run involving a climb of approximately 1000 m with a slope greater than 30%. The athletes were equipped with a portable respiratory inductive plethysmography system, a finger pulse oximeter and a global positioning unit (GPS). The ventilatory pattern (ventilation (VE), tidal volume (VT), respiratory rate (RR), and VE/VT ratio), thoraco-abdominal coordination, which is represented by the phase angle (PhA), and SpO2 were evaluated at rest and during the run. Before and after the run, we assessed respiratory function, respiratory muscle strength and the occurrence of interstitial pulmonary edema by thoracic ultrasound. Results Two subjects were excluded from the respiratory inductive plethysmography analysis due to motion artifacts. A quadratic relationship between the slope and the PhA was observed (r = 0.995, p = 0.036). When the slope increased above 30%, the PhA increased, indicating a reduction in thoraco-abdominal coordination. The reduced thoraco-abdominal coordina- tion was significantly related to reduced breathing efficiency (i.e., an increased VE/VT ratio; r = 0.961, p = 0.038) and SpO2 (r = -0.697, p<0.001). Lower SpO2 values were associated with lower speeds at 20% slope 40% (r = 0.335, p<0.001 for horizontal and r = 0.36, p<0.001 for vertical). The reduced thoraco-abdominal coordination and consequent reduction in SpO2 were associated with interstitial pulmonary edema. Conclusion Reductions in thoraco-abdominal coordination are associated with a less efficient ventilatory pattern and lower SpO2 during uphill running. This fact could have a negative effect on performance
    corecore