11 research outputs found

    Investigation of blood microcirculation parameters in patients with rheumatic diseases by videocapillaroscopy and laser Doppler flowmetry during cold pressor test

    Get PDF
    Videocapillaroscopy (VCS) and laser Doppler flowmetry (LDF) are non-invasive methods for evaluating microcirculation parameters. The VCS method is based on a high-speed video recording of capillaries in the nailfold. The recorded video frames are processed using a specialized algorithm to determine the red blood cells velocity. The LDF technique is based on the analysis of the Doppler shift of back-scattered laser radiation from moving red blood cells. In this work, simultaneous measurements of VCS and LDF have been performed in healthy volunteers and rheumatic patient. The study was conducted using a cold pressor test. Changes were recorded in response to cold exposure in rheumatic diseases

    Dynamic evaluation of blood flow microcirculation by combined use of the laser Doppler flowmetry and high-speed videocapillaroscopy methods

    No full text
    Abstract The dynamic light scattering methods are widely used in biomedical diagnostics involving evaluation of blood flow. However, there exist some difficulties in quantitative interpretation of backscattered light signals from the viewpoint of diagnostic information. This study considers the application of the high‐speed videocapillaroscopy (VCS) method that provides the direct measurement of the red blood cells (RBCs) velocity into a capillary. The VCS signal presents true oscillation nature of backscattered light caused by moving RBCs. Thus, the VCS signal can be assigned as a reference one with respect to more complicated signals like in laser Doppler flowmetry (LDF). An essential correlation between blood flow velocity oscillations in a separate human capillary and the integral perfusion estimate obtained by the LDF method has been found. The observation of blood flow by the VCS method during upper arm occlusion has shown emergence of the reverse blood flow effect in capillaries that corresponds to the biological zero signal in the LDF. The reverse blood flow effect has to be taken into account in interpretation of LDF signals

    Investigation of blood microcirculation parameters in patients with rheumatic diseases by videocapillaroscopy and laser Doppler flowmetry during cold pressor test

    No full text
    Abstract Videocapillaroscopy (VCS) and laser Doppler flowmetry (LDF) are non-invasive methods for evaluating microcirculation parameters. The VCS method is based on a high-speed video recording of capillaries in the nailfold. The recorded video frames are processed using a specialized algorithm to determine the red blood cells velocity. The LDF technique is based on the analysis of the Doppler shift of back-scattered laser radiation from moving red blood cells. In this work, simultaneous measurements of VCS and LDF have been performed in healthy volunteers and rheumatic patient. The study was conducted using a cold pressor test. Changes were recorded in response to cold exposure in rheumatic diseases

    Effect of Ce/Zr Composition on Structure and Properties of Ce1−xZrxO2 Oxides and Related Ni/Ce1−xZrxO2 Catalysts for CO2 Methanation

    No full text
    Ce1−xZrxO2 oxides (x = 0.1, 0.25, 0.5) prepared via the Pechini route were investigated using XRD analysis, N2 physisorption, TEM, and TPR in combination with density functional theory calculations. The Ni/Ce1−xZrxO2 catalysts were characterized via XRD analysis, SEM-EDX, TEM-EDX, and CO chemisorption and tested in carbon dioxide methanation. The obtained Ce1−xZrxO2 materials were single-phase solid solutions. The increase in Zr content intensified crystal structure strains and favored the reducibility of the Ce1−xZrxO2 oxides but strongly affected their microstructure. The catalytic activity of the Ni/Ce1−xZrxO2 catalysts was found to depend on the composition of the Ce1−xZrxO2 supports. The detected negative effect of Zr content on the catalytic activity was attributed to the decrease in the dispersion of the Ni0 nanoparticles and the length of metal–support contacts due to the worsening microstructure of Ce1−xZrxO2 oxides. The improvement of the redox properties of the Ce1−xZrxO2 oxide supports through cation modification can be negated by changes in their microstructure and textural characteristics

    Geographic and Temporal Variability of Hepatitis E Virus Circulation in the Russian Federation

    No full text
    The factors influencing hepatitis E virus (HEV) circulation remain largely unexplored. We investigated HEV seroprevalence in humans and the prevalence of infection in farm pigs and rabbits in different regions of the Russian Federation, as well as the genetic diversity and population dynamics of the HEV. The anti-HEV IgG antibody detection rates in the general population increase significantly with age, from 1.5% in children and adolescents under 20 years old to 4.8% in adults aged between 20 and 59 years old to 16.7% in people aged 60 years and older. HEV seroprevalence varies between regions, with the highest rate observed in Belgorod Region (16.4% compared with the national average of 4.6%), which also has the country’s highest pig population. When compared with the archival data, both increases and declines in HEV seroprevalence have been observed within the last 10 years, depending on the study region. Virus shedding has been detected in 19 out of the 21 pig farms surveyed. On one farm, the circulation of the same viral strain for five years was documented. All the human and animal strains belonged to the HEV-3 genotype, with its clade 2 sequences being predominant in pigs. The sequences are from patients, pigs, and sewage from pig farms clustered together, suggesting a zoonotic infection in humans and possible environmental contamination. The HEV-3 population size that was predicted using SkyGrid reconstruction demonstrated exponential growth in the 1970s–1990s, with a subsequent decline followed by a short rise around the year 2010, the pattern being similar to the dynamics of the pig population in the country. The HEV-3 reproduction number (Re) that was predicted using birth–death skyline analysis has fluctuated around 1 over the past 20 years in Russia but is 10 times higher in Belgorod Region. In conclusion, the HEV-3 circulation varies both geographically and temporally, even within a single country. The possible factors contributing to this variability are largely related to the circulation of the virus among farm pigs
    corecore