930 research outputs found

    Determinants of Return to Work in Patients with Hand Disorders and Hand Injuries

    Get PDF
    Introduction Return to work (RTW) in patients with hand disorders and hand injuries is determined by several determinants not directly related to the physical situation. Besides biomedical determinants, work-related and psychosocial determinants may influence RTW as well. This study is conducted to investigate the influence of these potential determinants on RTW in patients with hand disorders and hand injuries. Methods Included 91 patients who were operatively treated for a hand disorder or a hand injury, and who were employed prior to surgery. Patients answered several questionnaires on the aforementioned categories. Potential determinants significantly related to RTW in a univariate analysis were entered in a logistic regression for the total group and the acutely injured patients separately. Results Pain, accident location, job independence and symptoms of post-traumatic stress disorder (PTSD) were univariately associated with RTW. Pain was a determinant for late RTW in the total group and accident location and symptoms of PTSD in the acutely injured group. Conclusion Pain, accident location and symptoms of PTSD were most important in resuming work in hand injured patients or in patients with a hand disorder. These findings may indicate that attention should be paid to the treatment of pain, and to the development of symptoms of PTSD during rehabilitation. It may be necessary to make extra efforts aimed at RTW in patients who sustained their injury on the job

    An overview of the design, construction and performance of large area triple-GEM prototypes for future upgrades of the CMS forward muon system

    Get PDF
    GEM detectors are used in high energy physics experiments given their good spatial resolution, high rate capability and radiation hardness. An international collaboration is investigating the possibility of covering the 1.6 < vertical bar eta vertical bar < 2.4 region of the CMS muon endcaps with large-area triple-GEM detectors. The CMS high-eta area is actually not fully instrumented, only Cathode Strip Chamber (CSC) are installed. The vacant area presents an opportunity for a detector technology able to to cope with the harsh radiation environment; these micropattern gas detectors are an appealing option to simultaneously enhance muon tracking and triggering capabilities in a future upgrade of the CMS detector. A general overview of this feasibility study is presented. Design and construction of small (10cm x 10cm) and full-size trapezoidal (1m x 0.5m) triple-GEM prototypes is described. Results from measurements with x-rays and from test beam campaigns at the CERN SPS is shown for the small and large prototypes. Preliminary simulation studies on the expected muon reconstruction and trigger performances of this proposed upgraded muon system are reported

    Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System

    Full text link
    Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the 1.5<∣η∣<2.21.5 < \mid\eta\mid < 2.2 region of the muon endcap mainly to control muon level-1 trigger rates after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by 3,072 radial strips with 455 ÎŒ\murad pitch arranged in eight η\eta-sectors. We assembled a full-size GE1/1 prototype of 1m length at Florida Tech and tested it in 20-120 GeV hadron beams at Fermilab using Ar/CO2_{2} 70:30 and the RD51 scalable readout system. Four small GEM detectors with 2-D readout and an average measured azimuthal resolution of 36 ÎŒ\murad provided precise reference tracks. Construction of this largest GEM detector built to-date is described. Strip cluster parameters, detection efficiency, and spatial resolution are studied with position and high voltage scans. The plateau detection efficiency is [97.1 ±\pm 0.2 (stat)]\%. The azimuthal resolution is found to be [123.5 ±\pm 1.6 (stat)] ÎŒ\murad when operating in the center of the efficiency plateau and using full pulse height information. The resolution can be slightly improved by ∌\sim 10 ÎŒ\murad when correcting for the bias due to discrete readout strips. The CMS upgrade design calls for readout electronics with binary hit output. When strip clusters are formed correspondingly without charge-weighting and with fixed hit thresholds, a position resolution of [136.8 ±\pm 2.5 stat] ÎŒ\murad is measured, consistent with the expected resolution of strip-pitch/12\sqrt{12} = 131.3 ÎŒ\murad. Other η\eta-sectors of the detector show similar response and performance.Comment: 8 pages, 32 figures, submitted to Proc. 2014 IEEE Nucl. Sci. Symposium, Seattle, WA, reference adde

    A novel application of Fiber Bragg Grating (FBG) sensors in MPGD

    Full text link
    We present a novel application of Fiber Bragg Grating (FBG) sensors in the construction and characterisation of Micro Pattern Gaseous Detector (MPGD), with particular attention to the realisation of the largest triple (Gas electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of about 0.5 m2 active area each, employing three GEM foils per chamber, to be installed in the forward region of the CMS endcap during the long shutdown of LHC in 2108-2019. The large active area of each GE1/1 chamber consists of GEM foils that are mechanically stretched in order to secure their flatness and the consequent uniform performance of the GE1/1 chamber across its whole active surface. So far FBGs have been used in high energy physics mainly as high precision positioning and re-positioning sensors and as low cost, easy to mount, low space consuming temperature sensors. FBGs are also commonly used for very precise strain measurements in material studies. In this work we present a novel use of FBGs as flatness and mechanical tensioning sensors applied to the wide GEM foils of the GE1/1 chambers. A network of FBG sensors have been used to determine the optimal mechanical tension applied and to characterise the mechanical tension that should be applied to the foils. We discuss the results of the test done on a full-sized GE1/1 final prototype, the studies done to fully characterise the GEM material, how this information was used to define a standard assembly procedure and possible future developments.Comment: 4 pages, 4 figures, presented by Luigi Benussi at MPGD 2015 (Trieste, Italy). arXiv admin note: text overlap with arXiv:1512.0848

    Development and performance of Triple-GEM detectors for the upgrade of the muon system of the CMS experiment

    Get PDF
    The CMS Collaboration is evaluating GEM detectors for the upgrade of the muon system. This contribution will focus on the R&D performed on chambers design features and will discuss the performance of the upgraded detector

    Design of a constant fraction discriminator for the VFAT3 front-end ASIC of the CMS GEM detector

    Get PDF
    In this work the design of a constant fraction discriminator (CFD) to be used in the VFAT3 chip for the read-out of the triple-GEM detectors of the CMS experiment, is described. A prototype chip containing 8 CFDs was implemented using 130 nm CMOS technology and test results are shown. © CERN 2016

    What's in a score:A longitudinal investigation of scores based on item response theory and classical test theory for the Amsterdam Instrumental Activities of Daily Living Questionnaire in cognitively normal and impaired older adults

    Get PDF
    OBJECTIVE:We aimed to investigate whether item response theory (IRT)-based scoring allows for a more accurate, responsive, and less biased assessment of everyday functioning than traditional classical test theory (CTT)-based scoring, as measured with the Amsterdam Instrumental Activities of Daily Living Questionnaire. METHOD: In this longitudinal multicenter study including cognitively normal and impaired individuals, we examined IRT-based and CTT-based score distributions and differences between diagnostic groups using linear regressions, and investigated scale attenuation. We compared change over time between scoring methods using linear mixed models with random intercepts and slopes for time.RESULTS: Two thousand two hundred ninety-four participants were included (66.6 ± 7.7 years, 54% female): n = 2,032 (89%) with normal cognition, n = 93 (4%) with subjective cognitive decline, n = 79 (3%) with mild cognitive impairment, and n = 91 (4%) with dementia. At baseline, IRT-based and CTT-based scores were highly correlated (r = -0.92). IRT-based scores showed less scale attenuation than CTT-based scores. In a subsample of n = 1,145 (62%) who were followed for a mean of 1.3 (SD = 0.6) years, IRT-based scores declined significantly among cognitively normal individuals (unstandardized coefficient [B] = -0.15, 95% confidence interval, 95% CI [-0.28, -0.03], effect size = -0.02), whereas CTT-based scores did not (B = 0.20, 95% CI [-0.02, 0.41], effect size = 0.02). In the other diagnostic groups, effect sizes of change over time were similar. CONCLUSIONS: IRT-based scores were less affected by scale attenuation than CTT-based scores. With regard to responsiveness, IRT-based scores showed more signal than CTT-based scores in early disease stages, highlighting the IRT-based scores' superior suitability for use in preclinical populations. (PsycInfo Database Record (c) 2023 APA, all rights reserved).</p

    Quality control and beam test of GEM detectors for future upgrades of the CMS muon high rate region at the LHC

    Get PDF
    Gas Electron Multipliers (GEM) are a proven position sensitive gas detector technology which nowadays is becoming more widely used in High Energy Physics. GEMs offer an excellent spatial resolution and a high particle rate capability, with a close to 100% detection efficiency. In view of the high luminosity phase of the CERN Large Hadron Collider, these aforementioned features make GEMs suitable candidates for the future upgrades of the Compact Muon Solenoid (CMS) detector. In particular, the CMS GEM Collaboration proposes to cover the high-eta region of the muon system with large-area triple-GEM detectors, which have the ability to provide robust and redundant tracking and triggering functions. In this contribution, after a general introduction and overview of the project, the construction of full-size trapezoidal triple-GEM prototypes will be described in more detail. The procedures for the quality control of the GEM foils, including gain uniformity measurements with an x-ray source will be presented. In the past few years, several CMS triple-GEM prototype detectors were operated with test beams at the CERN SPS. The results of these test beam campaigns will be summarised

    Upper limb activity in myoelectric prosthesis users is biased towards the intact limb and appears unrelated to goal-directed task performance

    Get PDF
    Studies of the effectiveness of prosthetic hands involve assessing user performance on functional tasks in the lab/clinic, sometimes combined with self-report of real-world use. In this paper we compare real-world upper limb activity between a group of 20 myoelectric prosthesis users and 20 anatomically intact adults. Activity was measured from wrist-worn accelerometers over a 7-day period. The temporal patterns in upper limb activity are presented and the balance of activity between the two limbs quantified. We also evaluated the prosthesis users’ performance on a goal-directed task, characterised using measures including task success rate, completion time, gaze behaviour patterns, and kinematics (e.g. variability and patterns in hand aperture). Prosthesis users were heavily reliant on their intact limb during everyday life, in contrast to anatomically intact adults who demonstrated similar reliance on both upper limbs. There was no significant correlation between the amount of time a prosthesis was worn and reliance on the intact limb, and there was no significant correlation between either of these measures and any of the assessed kinematic and gaze-related measures of performance. We found participants who had been prescribed a prosthesis for longer to demonstrate more symmetry in their overall upper limb activity, although this was not reflected in the symmetry of unilateral limb use. With the exception of previously published case studies, this is the first report of real world upper limb activity in myoelectric prosthesis users and confirms the widely held belief that users are heavily reliant on their intact limb

    Overview of large area triple-GEM detectors for the CMS forward muon upgrade

    Get PDF
    In order to cope with the harsh environment expected from the high luminosity LHC, the CMS forward muon system requires an upgrade. The two main challenges expected in this environment are an increase in the trigger rate and increased background radiation leading to a potential degradation of the particle ID performance. Additionally, upgrades to other subdetectors of CMS allow for extended coverage for particle tracking, and adding muon system coverage to this region will further enhance the performance of CMS
    • 

    corecore