1,632 research outputs found

    Understanding the Impact of the Three-Dimensional Junction Thickness of Electrospun Bipolar Membranes on Electrochemical Performance

    Get PDF
    The use of electrospun bipolar membranes (BPMs) with an interfacial three-dimensional (3D) junction of entangled nano-/microfibers has been recently proposed as a promising fabrication strategy to develop high-performance BPMs. In these BPMs, the morphology and physical properties of the 3D junction are of utmost importance to maximize the membrane performance. However, a full understanding of the impact of the junction thickness on the membrane performance is still lacking. In this study, we have developed bipolar membranes with the same composition, only varying the 3D junction thicknesses, by regulating the electrospinning time used to deposit the nano-/microfibers at the junction. In total, four BPMs with 3D junction thicknesses of ∼4, 8, 17, and 35 μm were produced to examine the influence of the junction thickness on the membrane performance. Current-voltage curves for water dissociation of BPMs exhibited lower voltages for BPMs with thicker 3D junctions, as a result of a three-dimensional increase in the interfacial contact area between cation- and anion-exchange fibers and thus a larger water dissociation reaction area. Indeed, increasing the BPM thickness from 4 to 35 μm lowered the BPM water dissociation overpotential by 32%, with a current efficiency toward HCl/NaOH generation higher than 90%. Finally, comparing BPM performance during the water association operation revealed a substantial reduction in the voltage from levels of its supplied open circuit voltage (OCV), owing to excessive hydroxide ion (OH-) and proton (H+) leakage through the relevant layers. Overall, this work provides insights into the role of the junction thickness on electrospun BPM performance as a crucial step toward the development of membranes with optimal entangled junctions.</p

    Call-duration and triage decisions in out of hours cooperatives with and without the use of an expert system

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Cooperatives delivering out of hours care in the Netherlands are hesitant about the use of expert systems during triage. Apart from the extra costs, cooperatives are not sure that quality of triage is sufficiently enhanced by these systems and believe that call duration will be prolonged drastically. No figures about the influence of the use of an expert system during triage on call duration and triage decisions in out of hours care in the Netherlands are available.</p> <p>Methods</p> <p>Electronically registered data concerning call duration and triage decisions were collected in two cooperatives. One in Tilburg, a cooperative in a Southern city of the Netherlands using an expert system, and one in Groningen, a cooperative in a Northern city not using an expert system. Some other relevant information about the care process was collected additionally. Data about call duration was compared using an independent sample t-test. Data about call decisions was compared using Chi Square.</p> <p>Results</p> <p>The mean call time in the cooperative using the TAS expert system is 4.6 minutes, in the cooperative not using the expert system 3.9 minutes. A significant difference of 0.7 minutes (0.4 – 1.0, 95% CI) minutes. In the cooperative with an expert system a larger percentage of patients is handled by the assistant, patients are less often referred to a telephone consultation with the GP and are less likely to be offered a visit by the GP.</p> <p>A quick interpretation of the impact of the difference in triage decisions, show that these may be large enough to support the hypothesis that longer call duration is compensated for by less contacts with the GP (by telephone or face-to-face). There is no proof, however, that these differences are caused by the use of the triage system. The larger amount of calls handled by the assistant may be partly caused by the fact that the assistants in the cooperative with an expert system more often consult the GP during triage. And it is not likely that the larger amount of home visits in Groningen can be attributed to the absence of an expert system. The expert system only offers advice whether a GP should be seen, not in which way (by consultation in the office or by home visit).</p> <p>Conclusion</p> <p>The differences in call times between a cooperative using an expert system and a cooperative not using an expert system are small; 0.4 – 1.0 min. Differences in triage decisions were found, but it is not proven that these can be contributed to the use of an expert system.</p

    Chlorimipraminium picrate

    Get PDF
    The title compound {systematic name: 3-chloro-5-[3-(dimethyl­amino)prop­yl]-10,11-dihydro-5H-dibenz[b,f]azepinium picrate}, C19H24ClN2 +·C6H2N3O7 −, crystallizes with two independent cation–anion pairs in the asymmetric unit. The chlorimipraminium cation contains two benzene rings (one with a chloro substituent) fused to a V-shaped seven-membered azepine ring whose mean planes are separated by 61.1 (0) and 66.5 (8)° with a 3-(dimethyl­amino)propyl group extending away from the apex of this ring. In the picrate anion, the mean planes of the two o-NO2 groups in each anion are twisted by 3.7 (2)/31.9 (3) and 31.3 (1)/11.4 (0)°, respectively, with respect to the mean plane of the six-membered benzene ring. The phenolate O atoms are bent slightly away from the mean plane of the benzene ring. The mean planes of the p-NO2 groups are twisted by 6.6 (1) and 2.88°, respectively, from the mean plane of the benzene ring. The crystal packing features bifurcated N—H⋯(O,O) inter­molecular hydrogen-bond inter­action, which connects each cation–anion pair. Additional π–π ring and C—H⋯π weak inter­molecular inter­actions are also observed

    Striking increase in incidence of prostate cancer in men aged < 60 years without improvement in prognosis

    Get PDF
    Increased awareness and improved diagnostic techniques have led to earlier diagnosis of prostate cancer and increased detection of subclinical cases, resulting in improved prognosis. We postulated that the considerable increase in incidence under age 60 is not attributable only to increased detection. To test this hypothesis, we studied incidence, mortality and relative survival among middle-aged patients diagnosed in south-east Netherlands and East Anglia (UK) between 1971 and 1994. Prostate-specific antigen (PSA) testing did not occur before 1990. Between 1971 and 1989, the age-standardized incidence at ages40–59 increased from 8.8 to 12.5 per 105 in The Netherlands and from 7.0 to 11.6 per 105 in East Anglia.Five-year relative survival did not improve in East Anglia and even declined in south-east Netherlands from 65% [95% confidence interval (CI) 47–83) in 1975–79 to 48% (CI 34–62) in 1985–89. Mortality due to prostate cancer among men aged 45–64 years increased by 50% in south-east Netherlands and by 61% in East Anglia between 1971 and 1989, but decreased slightly in the 1990s. Because other factors adversely influencing the prognosis are unlikely, our results indicate an increase in the incidence of fatal prostate cancer among younger men in the era preceding PSA testing. © 1999 Cancer Research Campaig

    Considering the influence of coronary motion on artery-specific biomechanics using fluid-structure interaction simulation

    Get PDF
    The endothelium in the coronary arteries is subject to wall shear stress and vessel wall strain, which influences the biology of the arterial wall. This study presents vessel-specific fluid-structure interaction (FSI) models of three coronary arteries, using directly measured experimental geometries and boundary conditions. FSI models are used to provide a more physiologically complete representation of vessel biomechanics, and have been extended to include coronary bending to investigate its effect on shear and strain. FSI both without- and with-bending resulted in significant changes in all computed shear stress metrics compared to CFD (p = 0.0001). Inclusion of bending within the FSI model produced highly significant changes in Time Averaged Wall Shear Stress (TAWSS) + 9.8% LAD, + 8.8% LCx, - 2.0% RCA; Oscillatory Shear Index (OSI) + 208% LAD, 0% LCx, + 2600% RCA; and transverse wall Shear Stress (tSS) + 180% LAD, + 150% LCx and + 200% RCA (all p < 0.0001). Vessel wall strain was homogenous in all directions without-bending but became highly anisotropic under bending. Changes in median cyclic strain magnitude were seen for all three vessels in every direction. Changes shown in the magnitude and distribution of shear stress and wall strain suggest that bending should be considered on a vessel-specific basis in analyses of coronary artery biomechanics

    Unrelated Helpers in a Primitively Eusocial Wasp: Is Helping Tailored Towards Direct Fitness?

    Get PDF
    The paper wasp Polistes dominulus is unique among the social insects in that nearly one-third of co-foundresses are completely unrelated to the dominant individual whose offspring they help to rear and yet reproductive skew is high. These unrelated subordinates stand to gain direct fitness through nest inheritance, raising the question of whether their behaviour is adaptively tailored towards maximizing inheritance prospects. Unusually, in this species, a wealth of theory and empirical data allows us to predict how unrelated subordinates should behave. Based on these predictions, here we compare helping in subordinates that are unrelated or related to the dominant wasp across an extensive range of field-based behavioural contexts. We find no differences in foraging effort, defense behaviour, aggression or inheritance rank between unrelated helpers and their related counterparts. Our study provides no evidence, across a number of behavioural scenarios, that the behaviour of unrelated subordinates is adaptively modified to promote direct fitness interests

    What are we measuring? A critique of range of motion methods currently in use for Dupuytren's disease and recommendations for practice

    Get PDF
    Background: Range of motion is the most frequently reported measure used in practice to evaluate outcomes. A goniometer is the most reliable tool to assess range of motion yet, the lack of consistency in reporting prevents comparison between studies. The aim of this study is to identify how range of motion is currently assessed and reported in Dupuytren’s disease literature. Following analysis recommendations for practice will be made to enable consistency in future studies for comparability. This paper highlights the variation in range of motion reporting in Dupuytren’s disease. Methods: A Participants, Intervention, Comparison, Outcomes and Study design format was used for the search strategy and search terms. Surgery, needle fasciotomy or collagenase injection for primary or recurrent Dupuytren’s disease in adults were included if outcomes were monitored using range of motion to record change. A literature search was performed in May 2013 using subject heading and free-text terms to also capture electronic publications ahead of print. In total 638 publications were identified and following screening 90 articles met the inclusion criteria. Data was extracted and entered onto a spreadsheet for analysis. A thematic analysis was carried out to establish any duplication, resulting in the final range of motion measures identified. Results: Range of motion measurement lacked clarity, with goniometry reportedly used in only 43 of the 90 studies, 16 stated the use of a range of motion protocol. A total of 24 different descriptors were identified describing range of motion in the 90 studies. While some studies reported active range of motion, others reported passive or were unclear. Eight of the 24 categories were identified through thematic analysis as possibly describing the same measure, ‘lack of joint extension’ and accounted for the most frequently used. Conclusions: Published studies lacked clarity in reporting range of motion, preventing data comparison and meta-analysis. Percentage change lacks context and without access to raw data, does not allow direct comparison of baseline characteristics. A clear description of what is being measured within each study was required. It is recommended that range of motion measuring and reporting for Dupuytren’s disease requires consistency to address issues that fall into 3 main categories:- Definition of terms Protocol statement Outcome reportin

    Neuropsychological patterns following lesions of the anterior insula in a series of forty neurosurgical patients

    Get PDF
    In the present study we investigated the effects of lesions affecting mainly the anterior insula in a series of 22 patients with lesions in the left hemisphere (LH), and 18 patients with lesions involving the right hemisphere (RH). The site of the lesion was established by performing an overlap of the probabilistic cytoarchitectonic maps of the posterior insula. Here we report the patients\u2019 neuropsychological profile and an analysis of their pre-surgical symptoms. We found that pre-operatory symptoms significantly differed in patients depending on whether the lesion affected the right or left insula and a strict parallelism between the patterns emerged in the pre-surgery symptoms analysis, and the patients\u2019 cognitive profile. In particular, we found that LH patients showed cognitive deficits. By contrast, the RH patients, with the exception of one case showing an impaired performance at the visuo-spatial planning test were within the normal range in performing all the tests. In addition, a sub-group of patients underwent to the post-surgery follow-up examination
    corecore