81 research outputs found
Recommended from our members
Enzymatic Synthesis of Poly(alkylene succinate)s: Influence of Reaction Conditions
Application of lipases (preferentially Candida antarctica Lipase B, CALB) for melt polycondensation of aliphatic polyesters by transesterification of activated dicarboxylic acids with diols allows to displace toxic metal and metal oxide catalysts. Immobilization of the enzyme enhances the activity and the temperature range of use. The possibility to use enzyme-catalyzed polycondensation in melt is studied and compared to results of polycondensations in solution. The experiments show that CALB successfully catalyzes polycondensation of both, divinyladipate and dimethylsuccinate, respectively, with 1,4-butanediol. NMR spectroscopy, relative molar masses obtained by size exclusion chromatography, MALDI-TOF MS and wide-angle X-ray scattering are employed to compare the influence of synthesis conditions for poly(butylene adipate) (PBA) and poly(butylene succinate) (PBS). It is shown that the enzymatic activity of immobilized CALB deviates and influences the molar mass. CALB-catalyzed polycondensation of PBA in solution for 24 h at 70 °C achieves molar masses of up to Mw~60,000 g/mol, higher than reported previously and comparable to conventional PBA, while melt polycondensation resulted in a moderate decrease of molar mass to Mw~31,000. Enzymatically catalyzed melt polycondensation of PBS yields Mw~23,400 g/mol vs. Mw~40,000 g/mol with titanium(IV)n-butoxide. Melt polycondensation with enzyme catalysis allows to reduce the reaction time from days to 3–4 h
Recommended from our members
Design of Polymer-Embedded Heterogeneous Fenton Catalysts for the Conversion of Organic Trace Compounds
Advanced oxidation processes are the main way to remove persistent organic trace compounds from water. For these processes, heterogeneous Fenton catalysts with low iron leaching and high catalytic activity are required. Here, the preparation of such catalysts consisting of silica-supported iron oxide (Fe2O3/SiOx) embedded in thermoplastic polymers is presented. The iron oxide catalysts are prepared by a facile sol–gel procedure followed by thermal annealing (calcination). These materials are mixed in a melt compounding process with modified polypropylenes to stabilize the Fe2O3 catalytic centers and to further reduce the iron leaching. The catalytic activity of the composites is analyzed by means of the Reactive Black 5 (RB5) assay, as well as by the conversion of phenol which is used as an example of an organic trace compound. It is demonstrated that embedding of silica-supported iron oxide in modified polypropylene turns the reaction order from pseudo-first order (found for Fe2O3/SiOx catalysts), which represents a mainly homogeneous Fenton reaction, to pseudo-zeroth order in the polymer composites, indicating a mainly heterogeneous, surface-diffusion-controlled process
The randomized shortened dental arch study (RaSDA): design and protocol
<p>Abstract</p> <p>Background</p> <p>Various treatment options for the prosthetic treatment of jaws where all molars are lost are under discussion. Besides the placement of implants, two main treatment types can be distinguished: replacement of the missing molars with removable dental prostheses and non-replacement of the molars, i.e. preservation of the shortened dental arch. Evidence is lacking regarding the long-term outcome and the clinical performance of these approaches. High treatment costs and the long time required for the treatment impede respective clinical trials.</p> <p>Methods/design</p> <p>This 14-center randomized controlled investigator-initiated trial is ongoing. Last patient out will be in 2010. Patients over 35 years of age with all molars missing in one jaw and with at least both canines and one premolar left on each side were eligible. One group received a treatment with removable dental prostheses for molar replacement (treatment A). The other group received a treatment limited to the replacement of all missing anterior and premolar teeth using fixed bridges (treatment B). A pilot trial with 32 patients was carried out. Two hundred and fifteen patients were enrolled in the main trial where 109 patients were randomized for treatment A and 106 for treatment B. The primary outcome measure is further tooth loss during the 5-year follow-up. The secondary outcome measures encompassed clinical, technical and subjective variables. The study is funded by the Deutsche Forschungsgemeinschaft (German Research Foundation, DFG WA 831/2-1, 2-2, 2-3, 2-4, 2-5).</p> <p>Discussion</p> <p>The particular value of this trial is the adaptation of common design components to the very specific features of complex dental prosthetic treatments. The pilot trial proved to be indispensable because it led to a number of adjustments in the study protocol that considerably improved the practicability. The expected results are of high clinical relevance and will show the efficacy of two common treatment approaches in terms of oral health. An array of secondary outcome measures will deliver valuable supplementary information. If the results can be implemented in the clinical practice, the daily dental care should strongly profit thereof.</p> <p>Trial registration</p> <p>The trial is registered at ClinicalTrials.gov under ISRCTN68590603 (pilot trial) and ISRCTN97265367 (main trial).</p
Sex difference and intra-operative tidal volume: Insights from the LAS VEGAS study
BACKGROUND: One key element of lung-protective ventilation is the use of a low tidal volume (VT). A sex difference in use of low tidal volume ventilation (LTVV) has been described in critically ill ICU patients.OBJECTIVES: The aim of this study was to determine whether a sex difference in use of LTVV also exists in operating room patients, and if present what factors drive this difference.DESIGN, PATIENTS AND SETTING: This is a posthoc analysis of LAS VEGAS, a 1-week worldwide observational study in adults requiring intra-operative ventilation during general anaesthesia for surgery in 146 hospitals in 29 countries.MAIN OUTCOME MEASURES: Women and men were compared with respect to use of LTVV, defined as VT of 8 ml kg-1 or less predicted bodyweight (PBW). A VT was deemed 'default' if the set VT was a round number. A mediation analysis assessed which factors may explain the sex difference in use of LTVV during intra-operative ventilation.RESULTS: This analysis includes 9864 patients, of whom 5425 (55%) were women. A default VT was often set, both in women and men; mode VT was 500 ml. Median [IQR] VT was higher in women than in men (8.6 [7.7 to 9.6] vs. 7.6 [6.8 to 8.4] ml kg-1 PBW, P < 0.001). Compared with men, women were twice as likely not to receive LTVV [68.8 vs. 36.0%; relative risk ratio 2.1 (95% CI 1.9 to 2.1), P < 0.001]. In the mediation analysis, patients' height and actual body weight (ABW) explained 81 and 18% of the sex difference in use of LTVV, respectively; it was not explained by the use of a default VT.CONCLUSION: In this worldwide cohort of patients receiving intra-operative ventilation during general anaesthesia for surgery, women received a higher VT than men during intra-operative ventilation. The risk for a female not to receive LTVV during surgery was double that of males. Height and ABW were the two mediators of the sex difference in use of LTVV.TRIAL REGISTRATION: The study was registered at Clinicaltrials.gov, NCT01601223
Online chemical adsorption studies of Hg, Tl, and Pb on SiO2 and Au surfaces in preparation for chemical investigations on Cn, Nh, and Fl at TASCA
Online gas-solid adsorption studies with single-atom quantities of Hg, Tl, and Pb, the lighter homologs of the superheavy elements (SHE) copernicium (Cn, Z =112), nihonium (Nh, Z =113), and flerovium (Fl, Z =114), were carried out using short-lived radioisotopes. The interaction with Au and SiO 2 surfaces was studied and the overall chemical yield was determined. Suitable radioisotopes were produced in fusion-evaporation reactions, isolated in the gas-filled recoil separator TASCA, and flushed rapidly to an adjacent setup of two gas chromatography detector arrays covered with SiO 2 (first array) and Au (second array). While Tl and Pb adsorbed on the SiO 2 surface, Hg interacts only weakly and reached the Au-covered array. Our results contribute to elucidating the influence of relativistic effects on chemical properties of the heaviest elements by providing experimental data on these lighter homologs
- …