68 research outputs found

    Characterisation of a cobalt-60 small-beam animal irradiator using a realtime silicon pixelated detector

    Get PDF
    The paper presents a study performed by the Centre for Medical Radiation Physics (CMRP) using a high spatial and temporal resolution silicon pixelated detector named MagicPlate- 512. The study focuses on the characterisation of three pencil beams from a low-dose rate, 6 TBq, cobalt-60 source, in terms of percentage depth dose, beam profiles, output factor and shutter timing. Where applicable, the findings were verified against radiochromic EBT3 film and ionization chambers. It was found that the results of the MagicPlate-512 and film agreed within 0.9 mm for penumbra and full-width at half-maximum measurements of the beam profiles, and within 0.75% for percentage depth dose study. The dose rate of the cobalt-60 source was determined to be (10.65±0.03) cGy/min at 1.5 cm depth in Solid Water. A significant asymmetry of the small pencil beam profile was found, which is due to the irregular machining of the small collimator. The average source shutter speed was calculated to be 26 cm/s. The study demonstrates that the MagicPlate-512 dosimetry system, developed at CMRP, is capable of beam characterisation even in cases of very low dose rate sources

    X-Tream: a novel dosimetry system for Synchrotron Microbeam Radiation Therapy

    Get PDF
    Microbeam Radiation Therapy (MRT) is a radiation treatment technique under development for inoperable brain tumors. MRT is based on the use of a synchrotron generated X-ray beam with an extremely high dose rate ( ~ 20 kGy/sec), striated into an array of X-ray micro-blades. In order to advance to clinical trials, a real-time dosimeter with excellent spatial resolution must be developed for absolute dosimetry. The design of a real-time dosimeter for such a radiation scenario represents a significant challenge due to the high photon flux and vertically striated radiation field, leading to very steep lateral dose gradients. This article analyses the striated radiation field in the context of the requirements for temporal dosimetric measurements and presents the architecture of a new dosimetry system based on the use of silicon detectors and fast data acquisition electronic interface. The combined system demonstrates micrometer spatial resolution and microsecond real time readout with accurate sensitivity and linearity over five orders of magnitude of input signal. The system will therefore be suitable patient treatment plan verification and may also be expanded for in-vivo beam monitoring for patient safety during the treatment

    The clinical utility of the continuous performance test and objective measures of activity for diagnosing and monitoring ADHD in children: a systematic review

    Get PDF
    Attention deficit hyperactivity disorder (ADHD) is typically diagnosed using clinical observation and subjective informant reports. Once children commence ADHD medication, robust monitoring is required to detect partial or non-responses. The extent to which neuropsychological continuous performance tests (CPTs) and objective measures of activity can clinically aid the assessment and titration process in ADHD is not fully understood. This review describes the current evidence base for the use of CPTs and objectively measured activity to support the diagnostic procedure and medication management for children with ADHD. Four databases (PsycINFO, Medline, Allied and Complementary Medicine (AMED) and PsycARTICLES) were systematically searched to understand the current evidence base for: (1) the use of CPTs to aid clinical assessment of ADHD; (2) the use of CPTs to aid medication management; (3) the clinical utility of objective measures of activity in ADHD. Sixty relevant articles were identified. The search revealed six commercially available CPTs that had been reported on for their clinical use. There were mixed findings with regard to the use of CPTs to assess and manage medication, with contrasting evidence on their ability to support clinical decision making. There was a strong evidence base for the use of objective measures of activity to aid ADHD/non-ADHD group differentiation, which appears sensitive to medication effects and would also benefit from further research on their clinical utility. The findings suggest that combining CPTs and an objective measure of activity may be particularly useful as a clinical tool and worthy of further pursuit

    Cross-border trafficking in human beings: prevention and intervention strategies for reducing sexual exploitation

    Get PDF
    Over the years, growing attention has been given to the phenomenon of trafficking in human beings (THB). Sexual exploitation was until recently by far the most commonly identified feature of THB, followed by forced labour. Many activities to combat trafficking for the purpose of sexual exploitation have been initiated by numerous supranational, international as well as national organizations. Much is written about these initiatives, but some areas have been neglected. Knowledge on ‘what works’ is in particular limited. The growing attention to THB entails a demand for more information. The severity of the crime and the impact on its victims makes it of utmost importance to gain more insight into the working and effectiveness of anti-trafficking strategies and interventions. The main objective of this review was to assess the presently available evidence on the effects of interventions that aim to prevent and suppress trafficking in human beings

    The feasibility study and characterziation of a two-dimensional diode array in “magic phantom” for high dose rate brachytherapy quality assurance

    Get PDF
    High dose rate (HDR) brachytherapy is a radiation treatment technique capable of delivering large dose rates to the tumor. Radiation is delivered using remote afterloaders to drive highly active sources (commonly 192Ir with an air KERMA strength range between 20 000 and 40 000 U, where 1 U = 1 uGy m2/h in air) through applicators directly into the patient\u27s prescribed region of treatment. Due to the obvious ramifications of incorrect treatment while using such an active source, it is essential that there are methods for quality assurance (QA) that can directly and accurately verify the treatment plan and the functionality of the remote afterloader. This paper describes the feasibility study of a QA system for HDR brachytherapy using a phantom based two-dimensional 11 x 11 epitaxial diode array, named magic phantom
    • 