17 research outputs found

    Experimental study of energy performance in low-temperature hydronic heating systems

    Get PDF
    Energy consumption, thermal environment and environmental impacts were analytically and experimentally studied for different types of heat emitters. The heat emitters studied were conventional radiator, ventilation radiator, and floor heating with medium-, low-, and very-low-temperature supply, respectively. The ventilation system in the lab room was a mechanical exhaust ventilation system that provided one air change per hour of fresh air through the opening in the external wall with a constant temperature of 5 °C, which is the mean winter temperature in Copenhagen. The parameters studied in the climate chamber were supply and return water temperature from the heat emitters, indoor temperature, and heat emitter surface temperature. Experiments showed that the mean supply water temperature for floor heating was the lowest, i.e. 30 °C, but it was close to the ventilation radiator, i.e. 33 °C. The supply water temperature in all measurements for conventional radiator was significantly higher than ventilation radiator and floor heating; namely, 45 °C. Experimental results indicated that the mean indoor temperature was close to the acceptable level of 22 °C in all cases. For energy calculations, it was assumed that all heat emitters were connected to a ground-source heat pump. Analytical calculations showed that using ventilation radiator and floor heating instead of conventional radiator resulted in a saving of 17% and 22% in heat pump's electricity consumption, respectively. This would reduce the CO2 emission from the building's heating system by 21 % for the floor heating and by 18% for the ventilation radiator compared to the conventional radiator.QC 20160128</p

    Mapping Relevant Parameters for Efficient Operation of Low-Temperature Heating Systems in Nordic Single-Family Dwellings

    No full text
    The aim of this study was to map the parameters that have the greatest impact on the environmental impact of heating systems usually used in Nordic single-family dwellings. The study focused on mapping the technical requirements for efficient operation of heating systems in a broader context. The results suggest that the ability of a heating system to be operated with a low-temperature water supply depends to a large extent on the heating demand of a building. It was shown that an increase in the water flow rate in hydronic circuits would significantly increase the thermal efficiency from analyzed heating systems. This increase would not increase the pumping power need, nor would it create noise problems in distribution network if the distribution pipes and thermostatic valves were properly selected. However, this increase in water flow rate improved the efficiency of considered closed-loop heat pump. It was further shown that the efficiency of the heat pump could be additionally improved by halving the energy needs for the domestic hot-water and circulators. The main conclusion from this study is that exergy usage, CO2 emission and thereby environmental impact are significantly lower for heating systems that are operated with small temperature drops

    Mapping Relevant Parameters for Efficient Operation of Low-Temperature Heating Systems in Nordic Single-Family Dwellings

    No full text
    The aim of this study was to map the parameters that have the greatest impact on the environmental impact of heating systems usually used in Nordic single-family dwellings. The study focused on mapping the technical requirements for efficient operation of heating systems in a broader context. The results suggest that the ability of a heating system to be operated with a low-temperature water supply depends to a large extent on the heating demand of a building. It was shown that an increase in the water flow rate in hydronic circuits would significantly increase the thermal efficiency from analyzed heating systems. This increase would not increase the pumping power need, nor would it create noise problems in distribution network if the distribution pipes and thermostatic valves were properly selected. However, this increase in water flow rate improved the efficiency of considered closed-loop heat pump. It was further shown that the efficiency of the heat pump could be additionally improved by halving the energy needs for the domestic hot-water and circulators. The main conclusion from this study is that exergy usage, CO2 emission and thereby environmental impact are significantly lower for heating systems that are operated with small temperature drops

    Performance Analysis of a Geothermal Radiant Cooling System Supported by Dehumidification

    No full text
    Space cooling demand is increasing globally due to climate change. Cooling has also been linked to all 17 sustainable development goals of the United Nations. Adequate cooling improves productivity and thermal comfort and can also prevent health risks. Meanwhile, policy initiatives such as the European Union&rsquo;s Green Deal require participants to cut greenhouse gas emissions and reduce energy use. Therefore, novel cooling systems that are capable of efficiently producing high levels of thermal comfort are needed. Radiant cooling systems provide a design capable of fulfilling these goals, but their application in hot and humid climates is limited due to the risk of condensation. In this study, we compare the performances of radiant cooling systems with and without dehumidification. The studied systems are supplied by geothermal energy. The study is conducted using building energy models of a small office building belonging to a three-building school complex located in Sant Cugat near Barcelona in Spain. The studied location has a Mediterranean climate. The simulations are conducted using IDA Indoor Climate and Energy 4.8 simulation software. The results show that the radiant cooling system with dehumidification (RCD) produces considerably improved thermal comfort conditions, with maximum predicted mean vote (PMV) reached during the cooling season being 0.4 (neutral) and the maximum PMV reached by the radiant cooling system without dehumidification (RC) being 1.2 (slightly warm). However, the improved thermal comfort comes at the cost of reduced energy and exergy efficiency. The RCD system uses 2.2 times as much energy and 5.3 times as much exergy as the RC system. A sensitivity analysis is also conducted to assess the influence of selected input parameters on the simulation output. The results suggest that maximising dehumidification temperature and minimising ventilation flow rate can improve the energy and exergy efficiency of the RCD system while having a minor effect on thermal comfort