174 research outputs found

    Numerical Simulation of III-V Solar Cells Using D-AMPS

    Get PDF
    Numerical simulation of devices plays a crucial role in their design, performance prediction, and comprehension of the fundamental phenomena ruling their operation. Here, we present results obtained using the code D-AMPS-1D, that was conveniently modified to consider the particularities of III-V solar cell devices. This work, that is a continuation of a previous paper regarding solar cells for space applications, is focused on solar cells structures than find application for terrestrial use under concentrated solar illumination. The devices were fabricated at the Solar Energy Institute of the Technical University of Madrid (UPM). The first simulations results on InGaP cells are presented. The influence of band offsets and band bending at the window-emitter interface on the quantum efficiency was studied. A remarkable match of the experimental quantum efficiency was obtained. Finally, numerical simulation of single junction n-p InGaP-Ge solar cells was performed

    El clavo gamma en las fracturas pertrocantéreas de cadera. Revisión de 400 casos

    Get PDF
    Las fracturas de la extremidad proximal del fémur son las más incapacitantes del organismo, siendo de ellas las más frecuentes las fracturas pertrocantéreas. Establecemos un estudio retrospectivo de 400 fracturas tratadas en nuestro Servicio mediante clavo Gamma, destacando nuestros resultados tanto clínicos como radiológicos, pérdida sanguínea, complicaciones médicas, quirúrgicas y radiológicas. Consideramos el clavo Gamma como el método de osteosíntesis idóneo para el tratamiento de fracturas pertrocantéreas por asocial una implantación endomedular con el deslizamiento del tornillo cefálico, condiciones imprescindibles para una movilización y carga precoz tan importante en estos pacientes.Fractures of the proximal femur are the most invalidating type of fractures affecting the skeleton and the most frequently found is the pertrochanteric variant. We have studied 400 pertrochanteric fractures treated with the standard gamma nail, showing our clinical and radiological results, blood loss, medical and surgical complications. We consider the gamma nail as the "gold standard" in the surgical treatment of petrochanteric fractures because it combines the endomedullary position with the sliding screw allowing an early mobilization and weight bearing, limited only by the patient's general conditions

    Importancia de la colocación del tornillo cefálico y de la distancia al apex en fracturas pertrocantéreas tratadas con clavo gamma

    Get PDF
    Las fracturas pertrocantéreas son las más frecuentes de las fracturas de la extremidad proximal del fémur. El ortostatismo y marcha precoces son el objetivo que se busca con el tratamiento quirúrgico. Para evitar fracasos de la osteosíntesis será necesario un buen conocimiento de los factores más relacionados con la evolución de la fractura. De ellos el más dependiente del propio cirujano es la colocación del tornillo cefálico en la cabeza fermoral. Presentamos un estudio retrospectivo de la colocación del tornillo cefálio de 400 fracturas tratadas con clavo Gamma en nuestro servicio. También estudiamos la distancia al ápex y la impactación de la fractura, así como sus relaciones con el éxito y fracaso de la osteosíntesis. Según nuestra serie el fracaso de la osteosíntesis se produce en un 35,7 % de los casos de localización anterior-superior y en un 30,7% de los casos de localización posterior-inferior. Todos nuestros casos de "cut-out" se producen en valores de la distancia al ápex mayores de 28 mm. la impactación media es de 2.27% mm. en las fracturas estables y de 8.26 mm. en las inestables.Pertrochanteric fractures are the most frequent type of proximal femur fractures. The main objectives of surgical treatment are early mobilization and full weight bearing. A good knowledge of the factors related to failure of the implant is necessary to avoid them. The most important is the cephalic screw positioning because it is most dependent is the cephalic screw positioning because it is most dependent on surgical technique. We present a retrospective study about the cephalic screws positioning in 400 pertrochanteric fractures treated with gamma nail. We also assessed the tip-apex distance and impaction of the fracture, looking for any relationships between them and the failure of the implant. In our series, 37.7% of screw failures occurs in the anterior-superior localization, and 30,7% in posterior-inferior localization. All cut-outs produced in cases with a Tipe Ápex distance larger than 28 mm. The mean impaction in stable fractures as 2,27 mm and in unstable fractures was 8,26%

    Transformações induzidas na estrutura produtiva de pequenos produtores pelas medidas de política econômica, Cruzeiro do sul - RS, período 1971/72 a 1975/76.

    Get PDF
    Ao longo da primeira metade da presente década houve importantes mudanças na estrutura produtiva do setor agropecuário, estimuladas por políticas que pretendam fazer com que a agricultura se desenvolvesse ao ritmo da economia nacional em seu conjunto. Este artigo apresenta um estudo preliminar das mudanças ocorridas, a nível de exploração, em um município ocupado por pequenos produtores com produção diversificada. Os dados de campo foram obtidos em dois levantamentos, o primeiro deles em setembro de 1972 e o segundo em janeiro de 1977, sendo que os produtores entrevistados foram os mesmos nas duas oportunidades. Entre os resultados alcançados, destaca-se um forte incremento das culturas consorciadas que perderam muita importância. Com referência à pecuária, destacam-se incrementos na suinocultura e na produção de leite. Em relação à utilização de recursos observa-se um incremento na utilização de maquinaria e uma redução na utilização de mãode-obra contratada, especialmente nos estabelecimentos de maior área (entre 25 e 100 hectares). A renda da operação agrícola apresenta uma evolução favorável somente no caso desses estabelecimentos maiores

    Multi-wavelength observations of afterglow of GRB 080319B and the modeling constraints

    Get PDF
    We present observations of the afterglow of GRB 080319B at optical, mm and radio frequencies from a few hours to 67 days after the burst. Present observations along with other published multi-wavelength data have been used to study the light-curves and spectral energy distributions of the burst afterglow. The nature of this brightest cosmic explosion has been explored based on the observed properties and it's comparison with the afterglow models. Our results show that the observed features of the afterglow fits equally good with the Inter Stellar Matter and the Stellar Wind density profiles of the circum-burst medium. In case of both density profiles, location of the maximum synchrotron frequency νm\nu_m is below optical and the value of cooling break frequency νc\nu_c is below XX-rays, 104\sim 10^{4}s after the burst. Also, the derived value of the Lorentz factor at the time of naked eye brightness is 300\sim 300 with the corresponding blast wave size of 1018\sim 10^{18} cm. The numerical fit to the multi-wavelength afterglow data constraints the values of physical parameters and the emission mechanism of the burst.Comment: 8 Pages, 3 Figures, Accepted for publication to Astronomy and Astrophysics on 02/04/200

    Evaluación de la calidad de la energía en dos casos de estudio: distorsión armónica inyectada por un sistema fotovoltaico de 40 kw y emitida por las cargas de una vivienda unifamiliar

    Get PDF
    Los posibles efectos de la conexión de sistemas fotovoltaicos (FV) a la red eléctrica sobre la calidad del servicio, en particular en lo referente a la inyección de componentes armónicas, suelen ser una preocupación de las empresas distribuidoras y los entes de regulación. A fin de aportar datos cuantitativos en relación con este tema, se analizó la calidad de la energía: (i) en el punto de conexión de un sistema FV de 40 kW instalado en el Polo Científico y Tecnológico, y (ii) en uno de los circuitos eléctricos de una vivienda unifamiliar. Por un lado, las mediciones realizadas en el sistema FV permitieron verificar que las componentes armónicas de corriente inyectadas a la red están claramente por debajo de los límites establecidos por la norma IEC 61000-3-2. Por su parte, las mediciones efectuadas en la vivienda muestran que las componentes armónicas de corriente emitidas por electrodomésticos son significativamente mayores que las armónicas inyectadas por un inversor FV de potencia típica para una vivienda unifamiliar. Los análisis realizados permiten afirmar, en consecuencia, que la conexión de sistemas FV a la red eléctrica no afecta la calidad del servicio en cuanto a la distorsión armónica.The possible effects of the connection of photovoltaic (PV) systems to the power grid on service quality, particularly in relation to the injection of harmonic components, are often a concern of distribution companies and regulatory authorities. In order to provide quantitative data on this subject, the power quality was analyzed: (i) in the connection point of a 40 kW PV system installed in the Scientific and Technological Pole, and (ii) in one of the electrical circuits of a house. On one hand, measurements made in the 40 kW PV system allowed to verify that the current harmonic components injected into the network are clearly below the limits set by IEC 61000-3-2. Meanwhile, measurements performed in the electrical circuit of the house show that current harmonic components emitted by household appliances are significantly higher than the harmonics injected by a typical PV power inverter for a house. Therefore, the results presented in this paper support the conclusion that gridconnected PV systems do not affect the power quality in terms of harmonic distortion.Tema 13: Generación distribuida.Facultad de Arquitectura y Urbanism

    Evaluación de la calidad de la energía en dos casos de estudio: distorsión armónica inyectada por un sistema fotovoltaico de 40 kw y emitida por las cargas de una vivienda unifamiliar

    Get PDF
    Los posibles efectos de la conexión de sistemas fotovoltaicos (FV) a la red eléctrica sobre la calidad del servicio, en particular en lo referente a la inyección de componentes armónicas, suelen ser una preocupación de las empresas distribuidoras y los entes de regulación. A fin de aportar datos cuantitativos en relación con este tema, se analizó la calidad de la energía: (i) en el punto de conexión de un sistema FV de 40 kW instalado en el Polo Científico y Tecnológico, y (ii) en uno de los circuitos eléctricos de una vivienda unifamiliar. Por un lado, las mediciones realizadas en el sistema FV permitieron verificar que las componentes armónicas de corriente inyectadas a la red están claramente por debajo de los límites establecidos por la norma IEC 61000-3-2. Por su parte, las mediciones efectuadas en la vivienda muestran que las componentes armónicas de corriente emitidas por electrodomésticos son significativamente mayores que las armónicas inyectadas por un inversor FV de potencia típica para una vivienda unifamiliar. Los análisis realizados permiten afirmar, en consecuencia, que la conexión de sistemas FV a la red eléctrica no afecta la calidad del servicio en cuanto a la distorsión armónica.The possible effects of the connection of photovoltaic (PV) systems to the power grid on service quality, particularly in relation to the injection of harmonic components, are often a concern of distribution companies and regulatory authorities. In order to provide quantitative data on this subject, the power quality was analyzed: (i) in the connection point of a 40 kW PV system installed in the Scientific and Technological Pole, and (ii) in one of the electrical circuits of a house. On one hand, measurements made in the 40 kW PV system allowed to verify that the current harmonic components injected into the network are clearly below the limits set by IEC 61000-3-2. Meanwhile, measurements performed in the electrical circuit of the house show that current harmonic components emitted by household appliances are significantly higher than the harmonics injected by a typical PV power inverter for a house. Therefore, the results presented in this paper support the conclusion that gridconnected PV systems do not affect the power quality in terms of harmonic distortion.Tema 13: Generación distribuida.Facultad de Arquitectura y Urbanism

    La reconstrucción de un palimpsesto románico mediante técnicas no destructivas

    Get PDF
    The Gothic Cathedral of Tortosa (1346), is superposed over a Romanesque building (1178) as a palimpsest, which there is no physical evidence. The geophysical survey (2102-13), has provided some relevant data from the previous seo, which have enabled the location of some of its main features: apse, pillars of the nave and façade. With these data it is possible to understand the fitting of the process, constructive/ deconstructive of both buildings. The study concludes that the main structural elements of both buildings fit as a gear, and the possible dimensions of the Romanesque Seo are deducted through the evidences found in the subsoil.La catedral gótica de Tortosa (1346), se superpone sobre una construcción románica (1178) a modo de alimpsesto, de la cual no existe ninguna evidencia física. La prospección geofísica (2102-13), ha aportado algunos datos relevantes de la anterior seo, que han precisado la ubicación de alguna de sus partes principales: ábside, pilares de la nave y fachada. Con estos datos se puede entender el encaje del proceso, constructivo/deconstructivo de ambos edificios. El estudio concluye que los elementos estructurales más importantes de ambas edificaciones encajan a manera de engranaje, y se deducen las posibles dimensiones de la Seo románica en base a las evidencias encontradas en el subsuelo

    Evaluación de la calidad de la energía en dos casos de estudio: distorsión armónica inyectada por un sistema fotovoltaico de 40 kw y emitida por las cargas de una vivienda unifamiliar

    Get PDF
    Los posibles efectos de la conexión de sistemas fotovoltaicos (FV) a la red eléctrica sobre la calidad del servicio, en particular en lo referente a la inyección de componentes armónicas, suelen ser una preocupación de las empresas distribuidoras y los entes de regulación. A fin de aportar datos cuantitativos en relación con este tema, se analizó la calidad de la energía: (i) en el punto de conexión de un sistema FV de 40 kW instalado en el Polo Científico y Tecnológico, y (ii) en uno de los circuitos eléctricos de una vivienda unifamiliar. Por un lado, las mediciones realizadas en el sistema FV permitieron verificar que las componentes armónicas de corriente inyectadas a la red están claramente por debajo de los límites establecidos por la norma IEC 61000-3-2. Por su parte, las mediciones efectuadas en la vivienda muestran que las componentes armónicas de corriente emitidas por electrodomésticos son significativamente mayores que las armónicas inyectadas por un inversor FV de potencia típica para una vivienda unifamiliar. Los análisis realizados permiten afirmar, en consecuencia, que la conexión de sistemas FV a la red eléctrica no afecta la calidad del servicio en cuanto a la distorsión armónica.The possible effects of the connection of photovoltaic (PV) systems to the power grid on service quality, particularly in relation to the injection of harmonic components, are often a concern of distribution companies and regulatory authorities. In order to provide quantitative data on this subject, the power quality was analyzed: (i) in the connection point of a 40 kW PV system installed in the Scientific and Technological Pole, and (ii) in one of the electrical circuits of a house. On one hand, measurements made in the 40 kW PV system allowed to verify that the current harmonic components injected into the network are clearly below the limits set by IEC 61000-3-2. Meanwhile, measurements performed in the electrical circuit of the house show that current harmonic components emitted by household appliances are significantly higher than the harmonics injected by a typical PV power inverter for a house. Therefore, the results presented in this paper support the conclusion that gridconnected PV systems do not affect the power quality in terms of harmonic distortion.Tema 13: Generación distribuida.Facultad de Arquitectura y Urbanism
    corecore