2,272 research outputs found
Search for Neutron Flux Generation in a Plasma Discharge Electrolytic Cell
Following some recent unexpected hints of neutron production in setups like
high-voltage atmospheric discharges and plasma discharges in electrolytic
cells, we present a measurement of the neutron flux in a configuration similar
to the latter. We use two different types of neutron detectors,
poly-allyl-diglicol-carbonate (PADC, aka CR-39) tracers and Indium disks. At
95% C.L. we provide an upper limit of 1.5 neutrons cm^-2 s^-1 for the thermal
neutron flux at ~5 cm from the center of the cell. Allowing for a higher energy
neutron component the largest allowed flux is 64 neutrons cm^-2 s^-1. This
upper limit is two orders of magnitude smaller than what previously claimed in
an electrolytic cell plasma discharge experiment. Furthermore the behavior of
the CR-39 is discussed to point our possible sources of spurious signals.Comment: 4 pages, 3 figure
Silicon Photo-Multiplier radiation hardness tests with a beam controlled neutron source
We report radiation hardness tests performed at the Frascati Neutron
Generator on silicon Photo-Multipliers, semiconductor photon detectors built
from a square matrix of avalanche photo-diodes on a silicon substrate. Several
samples from different manufacturers have been irradiated integrating up to
7x10^10 1-MeV-equivalent neutrons per cm^2. Detector performances have been
recorded during the neutron irradiation and a gradual deterioration of their
properties was found to happen already after an integrated fluence of the order
of 10^8 1-MeV-equivalent neutrons per cm^2.Comment: 7 pages, 6 figures, Submitted to Nucl. Inst. Meth.
Quality of Life and psychopathology in adults who underwent Hematopoietic Stem Cell Transplantation (HSCT) in childhood: a qualitative and quantitative analysis.
Background: Patients who undergo pediatric Hematopoietic Stem Cell Transplantation (HSCT) may experience long-term psychological sequelae and poor Quality of Life (QoL) in adulthood. This study aimed to investigate subjective illness experience, QoL, and psychopathology in young adults who have survived pediatric HSCT.
Method: The study involved patients treated with HSCT in the Hematology-Oncology Department between 1984 and 2007. Psychopathology and QoL were investigated using the SCL-90-R and SF-36. Socio-demographic and medical information was also collected. Finally, participants were asked to write a brief composition about their experiences of illness and care. Qualitative analysis of the texts was performed using T-LAB, an instrument for text analysis that allows the user to highlight the occurrences and co-occurrences of lemma. Quantitative analyses were performed using non-parametric tests (Spearman correlations, Kruskal-Wallis and Mann-Whitney tests).
Results: Twenty-one patients (9 males) participated in the study. No significant distress was found on the SCL-90 Global Severity Index, but it was found on specific scales. On the SF-36, lower scores were reported on scales referring to bodily pain, general health, and physical and social functioning. All the measures were significantly (p < 0.05) associated with specific socio-demographic and medical variables (gender, type of pathology, type of HSCT, time elapsed between communication of the need to transplant and effective transplantation, and days of hospitalization). With regard to the narrative analyses, males focused on expressions related to the body and medical therapies, while females focused on people they met during treatment, family members, and donors. Low general health and treatment with autologous HSCT were associated with memories about chemotherapy, radiotherapy, and the body parts involved, while high general health was associated with expressions focused on gratitude (V-Test \ub1 1.96).
Conclusion: Pediatric HSCT survivors are more likely to experience psychological distress and low QoL in adulthood compared with the general population. These aspects, along with survivors' subjective illness experience, show differences according to specific medical and socio-demographic variables. Studies are needed in order to improve the care and long-term follow-up of these families
Neutron spectrometer for fast nuclear reactors
In this paper we describe the development and first tests of a neutron
spectrometer designed for high flux environments, such as the ones found in
fast nuclear reactors. The spectrometer is based on the conversion of neutrons
impinging on Li into and whose total energy comprises the
initial neutron energy and the reaction -value. The LiF layer is
sandwiched between two CVD diamond detectors, which measure the two reaction
products in coincidence. The spectrometer was calibrated at two neutron
energies in well known thermal and 3 MeV neutron fluxes. The measured neutron
detection efficiency varies from 4.2 to 3.5 for
thermal and 3 MeV neutrons, respectively. These values are in agreement with
Geant4 simulations and close to simple estimates based on the knowledge of the
Li(n,) cross section. The energy resolution of the spectrometer
was found to be better than 100 keV when using 5 m cables between the detector
and the preamplifiers.Comment: submitted to NI
Experimental determination of electron and hole mean drift distance: Application to chemical vapor deposition diamond
A study was performed on the experimental determination of electron and hole mean drift distance in chemical vapor deposition polycrystalline diamond. Air was used as an absorbing layer in order to change the energy of the impinging α particles. The results showed that the pumping process was much more effective on hole conduction
Systematic study of the normal and pumped state of high efficiency diamond particle detectors grown by chemical vapor deposition
The efficiency and charge collection distance (CCD) of nuclear particle detectors based on high quality diamond films grown by chemical vapor deposition (CVD) have been systematically studied as a function of the methane content in the growth gas mixture and for varying film thickness. The effects of preirradiation with β particles (pumping) have been thoroughly studied. The results fully support a recently proposed model [Marinelli et al., Appl. Phys. Lett. 75, 3216 (1999)] discussing the role of in-grain defects and grain boundaries in determining the charge collection spectra of CVD diamond films both in the normal and in the pumped state. The model allows us to quantitatively explain the dependence of CCD and efficiency on film thickness, giving a microscopic picture of the effects of preirradiation with ionizing radiation in CVD diamond films. The highest average CCD obtained is 145 μm in a 160 μm thick detector (corresponding to about 50% average efficiency), while the maximum value (about 70% efficiency) is close to 370 μm. In addition, CCD is shown to be higher than film thickness and to monotonically increase with thickness, indicating margins for further improvements. © 2001 American Institute of Physics
Distribuição espacial do conteúdo de carbono orgânico total no solo em um agroecossistema de terras baixas no sul do brasil.
Estudo da variabilidade espacial dos atributos químicos e físicos do solo em um agroecossistema de arroz irrigado para suporte à Agricultura de Precisão.
Unified theory for Goos-H\"{a}nchen and Imbert-Fedorov effects
A unified theory is advanced to describe both the lateral Goos-H\"{a}nchen
(GH) effect and the transverse Imbert-Fedorov (IF) effect, through representing
the vector angular spectrum of a 3-dimensional light beam in terms of a 2-form
angular spectrum consisting of its 2 orthogonal polarized components. From this
theory, the quantization characteristics of the GH and IF displacements are
obtained, and the Artmann formula for the GH displacement is derived. It is
found that the eigenstates of the GH displacement are the 2 orthogonal linear
polarizations in this 2-form representation, and the eigenstates of the IF
displacement are the 2 orthogonal circular polarizations. The theoretical
predictions are found to be in agreement with recent experimental results.Comment: 15 pages, 3 figure
Spectrometric performances of monocrystalline artificial diamond detectors operated at high temperature
- …
