413 research outputs found

    Spectrally Resolved Single-Photon Timing of Silicon Photomultipliers for Time-Domain Diffuse Spectroscopy

    Get PDF
    We characterized the single-photon timing response function of various silicon photomultipliers (SiPMs) over a broad (500-1100 nm) spectral range. We selected two SiPM manufacturers, and we investigated two active areas, i.e., a small (1-1.69 mm2 and a large (9 mm2) one, for each of them. We demonstrate that selected SiPMs are suitable for time-resolved diffuse optics (DO) applications where a very large detection area and sensitivity down to single photons are crucial to detecting the very faint return signal from biological tissues, like the brain, thus allowing replacement of photomultiplier tubes and opening the way to a novel generation of DO multichannel instrumentation. Due to our custom front-end electronics, we show the world's best single-photon timing resolution for SiPMs, namely, 57-ps full-width at half maximum for Hamamatsu 1.69 mm2 and 115 ps for Excelitas 9 mm2. Even further, we provide a thorough spectral investigation of the full single-photon timing response function, also detailing diffusion tails' time constants and dynamic range. The achieved insight and the reported performance open the way to a widespread diffusion of SiPMs not just in many-photon regimes (e.g., PET) but at single-photon counting regimes like DO as well

    Experimental sleep deprivation as a tool to test memory deficits in rodents.

    Get PDF
    Paradigms of sleep deprivation (SD) and memory testing in rodents (laboratory rats and mice) are here reviewed. The vast majority of these studies have been aimed at understanding the contribution of sleep to cognition, and in particular to memory. Relatively little attention, instead, has been devoted to SD as a challenge to induce a transient memory impairment, and therefore as a tool to test cognitive enhancers in drug discovery. Studies that have accurately described methodological aspects of the SD protocol are first reviewed, followed by procedures to investigate SD-induced impairment of learning and memory consolidation in order to propose SD protocols that could be employed as cognitive challenge. Thus, a platform of knowledge is provided for laboratory protocols that could be used to assess the efficacy of drugs designed to improve memory performance in rodents, including rodent models of neurodegenerative diseases that cause cognitive deficits, and Alzheimer's disease in particular. Issues in the interpretation of such preclinical data and their predictive value for clinical translation are also discussed

    Calcium-activated chloride currents in olfactory sensory neurons from mice lacking bestrophin-2

    Get PDF
    none8noOlfactory sensory neurons use a chloride-based signal amplification mechanism to detect odorants. The binding of odorants to receptors in the cilia of olfactory sensory neurons activates a transduction cascade that involves the opening of cyclic nucleotide-gated channels and the entry of Ca2+ into the cilia. Ca2+ activates a Cl- current that produces an efflux of Cl- ions and amplifies the depolarization. The molecular identity of Ca2+-activated Cl- channels is still elusive, although some bestrophins have been shown to function as Ca2+ -activated Cl- channels when expressed in heterologous systems. In the olfactory epithelium, bestrophin-2 (Best2) has been indicated as a candidate for being a molecular component of the olfactory Ca2+-activated Cl- channel. In this study, we have analysed mice lacking Best2. We compared the electrophysiological responses of the olfactory epithelium to odorant stimulation, as well as the properties of Ca2+-activated Cl- currents in wild-type (WT) and knockout (KO) mice for Best2. Our results confirm that Best2 is expressed in the cilia of olfactory sensory neurons, while odorant responses and Ca2+ -activated Cl- currents were not significantly different between WT and KO mice. Thus, Best2 does not appear to be the main molecular component of the olfactory channel. Further studies are required to determine the function of Best2 in the cilia of olfactory sensory neurons. © 2009 The Authors. Journal compilation © 2009 The Physiological Society.openPifferi S.; Dibattista M.; Sagheddu C.; Boccaccio A.; Al Qteishat A.; Ghirardi F.; Tirindelli R.; Menini A.Pifferi, S.; Dibattista, M.; Sagheddu, C.; Boccaccio, A.; Al Qteishat, A.; Ghirardi, F.; Tirindelli, R.; Menini, A

    Electrochemical Characterization and Electroanalytical Aplications of RGO_AuNPs Hybrids

    Get PDF
    A novel synthetic route for the synthesis of gold nanoparticles (AuNPs) modified graphene electrodes has been developed: Reduced Graphene Oxide (RGO) sheets are functionalized with pyrene linkers acting as growing sites for gold nanoparticles (AuNPs) of different dimensions (approximatively 5, 10 and 20 nm). The Au surface is functionalized with oleylamine or 3,4-dimethylbenzenethiol as capping agents. The hybrid material is deposited onto Carbon Screen Printed Electrodes (C-SPEs) for a deep physico-chemical and electrochemical characterization, using Cyclic Voltammetry (CV) and Electrochemical Impedance Spectroscopy (EIS) measurements. The role played by every single hybrid counterpart has been investigated, showing a synergistic effect, which is responsible of the enhancement of the system properties. The charge transfer from gold nanoparticles to graphene, assisted and stimulated by the pyrene linker, seems to be the key point to understand the peculiarities of this innovative material. The as prepared RGO-AuNPs hybrids have been used in the electroanalytical detection of both inorganic and organic species (arsenic, H2O2, dopamine), showing promising results in terms of sensitivities and detection limits. In particular, regarding the detection of the neurotransmitter dopamine by means of Differential Pulse Voltammetry in Phosphate Buffer Solution, a LOD of (3.3 \ub1 0.2) ppb has been reached, comparable with other electroanalytical results in the literature and in accordance with the benchmark for this molecule [1]. For arsenic detection, the hybrid devices show increased performances in comparison with bare gold or gold NPs, also allowing speciation between arsenic (III) and (V), appropriately adjusting the experimental conditions. In the case of H2O2, the hybrid devices display high electrocatalytic activity and fast electron-transfer kinetics, representing an ideal platform for developing oxidoreductase-based electrochemical biosensors as well as for detecting H2O2 in real samples. [1] J.A. Ribeiro, P.M.V. Fernandes, C.M. Pereira, F. Silva, Talanta 160 (2016) 653-679

    Optical Characterization of Benign and Malignant Breast Lesions by Perturbative Model

    Get PDF
    The characterization of benign and malignant breast lesions was performed by the use of a perturbative model. Concentrations of blood, lipid, water and collagen were obtained. Differences between lesions and healthy tissue were observed

    Post-processing of vis, nir, and swir multispectral images of paintings. New discovery on the the drunkenness of noah, painted by andrea sacchi, stored at palazzo chigi (ariccia, rome)

    Get PDF
    IR Reflectography applied to the identification of hidden details of paintings is extremely useful for authentication purposes and for revealing technical hidden features. Recently, multispectral imaging has replaced traditional imaging techniques thanks to the possibility to select specific spectral ranges bringing out interesting details of the paintings. VIS–NIR–SWIR images of one of the The Drunkenness of Noah versions painted by Andrea Sacchi, acquired with a modified reflex and InGaAs cameras, are presented in this research. Starting from multispectral images we performed post-processing analysis, using visible and infrared false-color images and principal component analysis (PCA) in order to highlight pentimenti and underdrawings. Radiography was performed in some areas to better investigate the inner pictorial layers. This study represents the first published scientific investigation of The Drunkenness of Noah’s artistic production, painted by Andrea Sacchi

    Enhanced performances of RGO-AuNPs hybrids towards electroanalytical applications

    Get PDF
    In recent years, lot of attention has been devoted to understanding the properties of hybrid nanocomposites, \u201cbrave new materials\u201d made of two or more organic and inorganic components. These systems show enhanced or novel physico-chemical properties with respect to the single components, resulting not only from the sum of the precursors\u2019 ones, but also from interactions occurring at their interface, the so-called \u201cheterojunction\u201d. However, a remaining challenge is to understand in depth the phenomena here originating. In the present work, to start fulfilling this gap, a deep electrochemical study of hybrids made of Reduced Graphene Oxide (RGO) and Au nanoparticles (NPs) is performed, analysing carefully the role played by each single component of the material on the electrochemical properties. In more details, RGO platforms are surface functionalized with 1-aminopyrene or 1-pyrene carboxylic acid that act as heteronucleation and growing sites of the amine- or thiol-coated Au NPs of different dimensions (from 3 to 20 nm). At first, Cyclic Voltammetry (CV) and Electrochemical Impedance Spectroscopy (EIS) measurements are carried out in order to characterize the different hybrids. Then, the materials are applied as electroanalytical sensors for both organic and inorganic molecules (dopamine and As, respectively) with very promising results, comparable or even better than analogous systems reported in literature. Moreover, preliminary tests on H2O2 detection open the venue to the application of these materials in biosensor applications. The properties of the hybrid nanocomposite, enhanced with respect to those of the single components, are ascribed to charge transfer occurring at the heterojunction from the Au NPs to the RGO, assisted and channelled by the pyrene linker

    Memory effect in silicon time-gated single-photon avalanche diodes

    Get PDF
    We present a comprehensive characterization of the memory effect arising in thin-junction silicon Single-Photon Avalanche Diodes (SPADs) when exposed to strong illumination. This partially unknown afterpulsing-like noise represents the main limiting factor when time-gated acquisitions are exploited to increase the measurement dynamic range of very fast (picosecond scale) and faint (single-photon) optical signals following a strong stray one. We report the dependences of this unwelcome signal-related noise on photon wavelength, detector temperature, and biasing conditions. Our results suggest that this so-called "memory effect" is generated in the deep regions of the detector, well below the depleted region, and its contribution on detector response is visible only when time-gated SPADs are exploited to reject a strong burst of photons
    • …
    corecore