165 research outputs found
Simultaneous in vivo positron emission tomography and magnetic resonance imaging
Positron emission tomography (PET) and magnetic resonance imaging (MRI) are widely used in vivo imaging technologies with both clinical and biomedical research applications. The strengths of MRI include high-resolution, high-contrast morphologic imaging of soft tissues; the ability to image physiologic parameters such as diffusion and changes in oxygenation level resulting from neuronal stimulation; and the measurement of metabolites using chemical shift imaging. PET images the distribution of biologically targeted radiotracers with high sensitivity, but images generally lack anatomic context and are of lower spatial resolution. Integration of these technologies permits the acquisition of temporally correlated data showing the distribution of PET radiotracers and MRI contrast agents or MR-detectable metabolites, with registration to the underlying anatomy. An MRI-compatible PET scanner has been built for biomedical research applications that allows data from both modalities to be acquired simultaneously. Experiments demonstrate no effect of the MRI system on the spatial resolution of the PET system and <10% reduction in the fraction of radioactive decay events detected by the PET scanner inside the MRI. The signal-to-noise ratio and uniformity of the MR images, with the exception of one particular pulse sequence, were little affected by the presence of the PET scanner. In vivo simultaneous PET and MRI studies were performed in mice. Proof-of-principle in vivo MR spectroscopy and functional MRI experiments were also demonstrated with the combined scanner
Pre-clinical imaging of invasive candidiasis using ImmunoPET/MR
This is the final version of the article. Available from Frontiers Media via the DOI in this record.The human commensal yeast Candida is the 4th most common cause of hospital-acquired bloodstream infections, with C. albicans accounting for the majority of the >400,000 life-threatening infections annually. Diagnosis of invasive candidiasis (IC), a disease encompassing candidemia (blood-borne yeast infection) and deep-seated organ infections, is a major challenge since clinical manifestations of the disease are indistinguishable from viral, bacterial and other fungal diseases, and diagnostic tests for biomarkers in the bloodstream such as PCR, ELISA and pan-fungal β-D-glucan lack either standardisation, sensitivity or specificity. Blood culture remains the gold standard for diagnosis, but test sensitivity is poor and turn-around time slow. Furthermore, cultures can only be obtained when the yeast resides in the bloodstream, with samples recovered from hematogenous infections often yielding negative results. Consequently, there is a pressing need for a diagnostic test that allows the identification of metastatic foci in deep-seated Candida infections, without the need for invasive biopsy. Here, we report the development of a highly specific mouse IgG3 monoclonal antibody (MC3) that binds to a putative β-1,2-mannan epitope present in high molecular weight mannoproteins and phospholipomannans on the surface of yeast and hyphal morphotypes of C. albicans, and its use as a [64Cu]NODAGA-labeled tracer for whole-body pre-clinical imaging of deep-seated C. albicans infections using antibody-guided positron emission tomography and magnetic resonance imaging (immunoPET/MRI). When used in a mouse intravenous (i.v.) challenge model that faithfully mimics disseminated C. albicans infections in humans, the [64Cu]NODAGA-MC3 tracer accurately detects infections of the kidney, the principal site of blood-borne candidiasis. Using a strain of the emerging human pathogen Candida auris that reacts with MC3 in vitro, but which is non-infective in i.v. challenged mice, we demonstrate the accuracy of the tracer in diagnosing invasive infections in vivo. This pre-clinical study demonstrates the principle of antibody-guided molecular imaging for detection of deep organ infections in IC, without the need for invasive tissue biopsy.This work was supported, in part, by the European Union Seventh Framework Program FP7/2007-2013 under grant 602820
Significant impact of different oxygen breathing conditions on noninvasive in vivo tumor-hypoxia imaging using [18F]-fluoro-azomycinarabino-furanoside ([18F]FAZA)
<p>Abstract</p> <p>Background</p> <p>[<sup>18</sup>F]FAZA is a PET biomarker with great potential for imaging tumor hypoxia. Aim of our study was to compare [<sup>18</sup>F]FAZA uptake in mice with subcutaneous exogenous CT26 colon carcinomas and endogenous polyoma middle-T (PyV-mT) mammary carcinomas and to analyze the influence of different breathing protocols in CT26 colon carcinomas as well as the reversibility or irreversibility of [<sup>18</sup>F]FAZA uptake.</p> <p>Methods</p> <p>We injected subcutaneous CT26 colon carcinoma or polyomavirus middle-T (PyV-mT) mammary carcinoma-bearing mice intravenously with<sup>18</sup>F-FAZA and performed PET scans 1-3 h post injection (<it>p.i.</it>). To analyze the impact of oxygen supply in CT26 carcinomas we used three different breathing protocols: (P0) air; (P1) 100% oxygen 1 h prior injection until 3 h <it>p.i.</it>; (P2) 100% oxygen breathing starting 2 min prior tracer injection until 1 h <it>p.i. </it>and during the PET scans; mice were breathing air between the 2 h and 3 h 10 min static scans. Normalized PET images were analyzed by using defined regions of interest. Finally, some mice were dissected for pimonidazole immunohistochemistry.</p> <p>Results</p> <p>There was no difference in<sup>18</sup>F-FAZA uptake 1-3 h <it>p.i. </it>between the two carcinoma types (CT26: 1.58 ± 0.45%ID/cc; PyV-mT: 1.47 ± 0.89%ID/cc, 1 h <it>p.i.</it>, tumor size < 0.5 cm<sup>3</sup>). We measured a significant tracer clearance, which was more pronounced in muscle tissue (P0). The [<sup>18</sup>F]FAZA tumor-to-muscle-ratios in CT26 colon carcinoma-bearing mice 2 h and 3 h, but not 1 h <it>p.i. </it>were significantly higher when the mice breathed air (P0: 3.56 ± 0.55, 3 h) compared to the oxygen breathing protocols (P1: 2.45 ± 0.58; P2: 2.77 ± 0.42, 3 h). Surprisingly, the breathing protocols P1 and P2 showed no significant differences in T/M ratios, thus indicating that the crucial [<sup>18</sup>F]FAZA uptake phase is during the first hour after [<sup>18</sup>F]FAZA injection. Importantly, the muscle clearance was not affected by the different oxygen breathing conditions while the tumor clearance was lower when mice were breathing air.</p> <p>Conclusion</p> <p>Exogenous CT26 colon carcinomas and endogenous polyoma middle-T (PyV-mT) mammary carcinomas showed no differences in [<sup>18</sup>F]FAZA uptake 1-3 h <it>p.i. </it>Our analysis using various breathing protocols with air (P0) and with pure oxygen (P1, P2) clearly indicate that [<sup>18</sup>F]FAZA is an appropriate PET biomarker for <it>in vivo </it>analysis of hypoxia revealing an enhanced tracer uptake in tumors with reduced oxygen supply. [<sup>18</sup>F]FAZA uptake was independent of tumor-type.</p
High-Resolution Motor State Detection in Parkinson's Disease Using Convolutional Neural Networks
Patients with advanced Parkinson's disease regularly experience unstable motor states. Objective and reliable monitoring of these fluctuations is an unmet need. We used deep learning to classify motion data from a single wrist-worn IMU sensor recording in unscripted environments. For validation purposes, patients were accompanied by a movement disorder expert, and their motor state was passively evaluated every minute. We acquired a dataset of 8,661 minutes of IMU data from 30 patients, with annotations about the motor state (OFF,ON, DYSKINETIC) based on MDS-UPDRS global bradykinesia item and the AIMS upper limb dyskinesia item. Using a 1-minute window size as an input for a convolutional neural network trained on data from a subset of patients, we achieved a three-class balanced accuracy of 0.654 on data from previously unseen subjects. This corresponds to detecting the OFF, ON, or DYSKINETIC motor state at a sensitivity/specificity of 0.64/0.89, 0.67/0.67 and 0.64/0.89, respectively. On average, the model outputs were highly correlated with the annotation on a per subject scale (r = 0.83/0.84;p < 0.0001), and sustained so for the highly resolved time windows of 1 minute (r = 0.64/0.70;p < 0.0001). Thus, we demonstrate the feasibility of long-term motor-state detection in a free-living setting with deep learning using motion data from a single IMU
Two birds with one stone: human SIRPα nanobodies for functional modulation and in vivo imaging of myeloid cells
Signal-regulatory protein α (SIRPα) expressed by myeloid cells is of particular interest for therapeutic strategies targeting the interaction between SIRPα and the “don’t eat me” ligand CD47 and as a marker to monitor macrophage infiltration into tumor lesions. To address both approaches, we developed a set of novel human SIRPα (hSIRPα)–specific nanobodies (Nbs). We identified high-affinity Nbs targeting the hSIRPα/hCD47 interface, thereby enhancing antibody-dependent cellular phagocytosis. For non-invasive in vivo imaging, we chose S36 Nb as a non-modulating binder. By quantitative positron emission tomography in novel hSIRPα/hCD47 knock-in mice, we demonstrated the applicability of 64Cu-hSIRPα-S36 Nb to visualize tumor infiltration of myeloid cells. We envision that the hSIRPα-Nbs presented in this study have potential as versatile theranostic probes, including novel myeloid-specific checkpoint inhibitors for combinatorial treatment approaches and for in vivo stratification and monitoring of individual responses during cancer immunotherapies
Cancer immunotherapy is accompanied by distinct metabolic patterns in primary and secondary lymphoid organs observed by non-invasive in vivo18F-FDG-PET
Purpose: Cancer immunotherapy depends on a systemic immune response, but the basic underlying mechanisms are still largely unknown. Despite the very successful and widespread use of checkpoint inhibitors in the clinic, the majority of cancer patients do not benefit from this type of treatment. In this translational study, we investigated whether noninvasive in vivo positron emission tomography (PET) imaging using 2-[18F]fluoro-2-deoxy-D-glucose (18F-FDG) is capable of detecting immunotherapy-associated metabolic changes in the primary and secondary lymphoid organs and whether this detection enables the prediction of a successful anti-cancer immune response. Methods: RIP1-Tag2 mice with progressed endogenous insular cell carcinomas underwent a combined cancer immunotherapy consisting of CD4+ T cells plus monoclonal antibodies (mAbs) against programmed death ligand-1 (PD-L1) and lymphocyte activation gene-3 (LAG-3) or a sham treatment after radiation-mediated immune cell depletion. A second cohort of RIP1-Tag2 mice underwent exclusive checkpoint inhibitor therapy (CIT) using anti-PD-L1/LAG-3 mAbs or sham treatment without initial immune cell depletion to mimic the clinical situation. All mice were monitored by 18F-FDG-PET combined with anatomical magnetic resonance imaging (MRI). In addition, we retrospectively analyzed PET / computed tomography (CT) scans (PET/CT) regarding 18F-FDG uptake of CIT-treated metastatic melanoma patients in the spleen (n=23) and bone marrow (BM; n=20) as well as blood parameters (n=17-21). Results: RIP1-Tag2 mice with advanced insular cell carcinomas treated with combination immunotherapy exhibited significantly increased 18F-FDG uptake in the spleen compared to sham-treated mice. Histopathology of the spleens from treated mice revealed atrophy of the white pulp with fewer germinal centers and an expanded red pulp with hyperplasia of neutrophils than those of sham-treated mice. Immunohistochemistry and flow cytometry analyses of the spleens revealed a lower number of T cells and a higher number of neutrophils compared to those in the spleens of sham-treated mice. Flow cytometry of the BM showed enhanced activation of T cells following the treatment schemes that included checkpoint inhibitors. The ratio of 18F-FDG uptake at baseline to the uptake at follow-up in the spleens of exclusively CIT-treated RIP1-Tag2 mice was significantly enhanced, but the ratio was not enhanced in the spleens of the sham-treated littermates. Flow cytometry analysis confirmed a reduced number of T cells in the spleens of exclusively CIT-treated mice compared to that of sham-treated mice. A retrospective analysis of clinical 18F-FDG-PET/CT scans revealed enhanced 18F-FDG uptake in the spleens of some successfully CIT-treated patients with metastatic melanoma, but there were no significant differences between responders and non-responders. The analysis of the BM in clinical 18F-FDG-PET/CT scans with a computational segmentation tool revealed significantly higher baseline 18F-FDG uptake in patients who responded to CIT than in non-responders, and this relationship was independent of bone metastasis, even in the baseline scan. Conclusions: Thus, we are presenting the first translational study of solid tumors focusing on the metabolic patterns of primary and secondary lymphoid organs induced by the systemic immune response after CIT. We demonstrate that the widely available 18F-FDG-PET modality is an applicable translational tool that has high potential to stratify patients at an early time point
- …