3,191 research outputs found

    Characterisation of re-entrant circuit (or rotational activity) in vitro using the HL1-6 myocyte cell line

    Get PDF
    Fibrillation is the most common arrhythmia observed in clinical practice. Understanding of the mechanisms underlying its initiation and maintenance remains incomplete. Functional re-entries are potential drivers of the arrhythmia. Two main concepts are still debated, the “leading circle” and the “spiral wave or rotor” theories. The homogeneous subclone of the HL1 atrial-derived cardiomyocyte cell line, HL1-6, spontaneously exhibits re-entry on a microscopic scale due to its slow conduction velocity and the presence of triggers, making it possible to examine re-entry at the cellular level. We therefore investigated the re-entry cores in cell monolayers through the use of fluorescence optical mapping at high spatiotemporal resolution in order to obtain insights into the mechanisms of re-entry. Re-entries in HL1-6 myocytes required at least two triggers and a minimum colony area to initiate (3.5 to 6.4 mm2). After electrical activity was completely stopped and re-started by varying the extracellular K+ concentration, re-entries never returned to the same location while 35% of triggers re-appeared at the same position. A conduction delay algorithm also allows visualisation of the core of the re-entries. This work has revealed that the core of re-entries is conduction blocks constituted by lines and/or groups of cells rather than the round area assumed by the other concepts of functional re-entry. This highlights the importance of experimentation at the microscopic level in the study of re-entry mechanisms

    A YOLOv5-based network for the detection of a diffuse reflectance spectroscopy probe to aid surgical guidance in gastrointestinal cancer surgery

    Get PDF
    PURPOSE: A positive circumferential resection margin (CRM) for oesophageal and gastric carcinoma is associated with local recurrence and poorer long-term survival. Diffuse reflectance spectroscopy (DRS) is a non-invasive technology able to distinguish tissue type based on spectral data. The aim of this study was to develop a deep learning-based method for DRS probe detection and tracking to aid classification of tumour and non-tumour gastrointestinal (GI) tissue in real time. METHODS: Data collected from both ex vivo human tissue specimen and sold tissue phantoms were used for the training and retrospective validation of the developed neural network framework. Specifically, a neural network based on the You Only Look Once (YOLO) v5 network was developed to accurately detect and track the tip of the DRS probe on video data acquired during an ex vivo clinical study. RESULTS: Different metrics were used to analyse the performance of the proposed probe detection and tracking framework, such as precision, recall, mAP 0.5, and Euclidean distance. Overall, the developed framework achieved a 93% precision at 23 FPS for probe detection, while the average Euclidean distance error was 4.90 pixels. CONCLUSION: The use of a deep learning approach for markerless DRS probe detection and tracking system could pave the way for real-time classification of GI tissue to aid margin assessment in cancer resection surgery and has potential to be applied in routine surgical practice

    Slow uniform electrical activation during sinus rhythm is an indicator of reentrant VT isthmus location and orientation in an experimental model of myocardial infarction.

    Get PDF
    BACKGROUND: To validate the predictability of reentrant circuit isthmus locations without ventricular tachycardia (VT) induction during high-definition mapping, we used computer methods to analyse sinus rhythm activation in experiments where isthmus location was subsequently verified by mapping reentrant VT circuits. METHOD: In 21 experiments using a canine postinfarction model, bipolar electrograms were obtained from 196-312 recordings with 4mm spacing in the epicardial border zone during sinus rhythm and during VT. From computerized electrical activation maps of the reentrant circuit, areas of conduction block were determined and the isthmus was localized. A linear regression was computed at three different locations about the reentry isthmus using sinus rhythm electrogram activation data. From the regression analysis, the uniformity, a measure of the constancy at which the wavefront propagates, and the activation gradient, a measure that may approximate wavefront speed, were computed. The purpose was to test the hypothesis that the isthmus locates in a region of slow uniform activation bounded by areas of electrical discontinuity. RESULTS: Based on the regression parameters, sinus rhythm activation along the isthmus near its exit proceeded uniformly (mean r2= 0.95±0.05) and with a low magnitude gradient (mean 0.37±0.10mm/ms). Perpendicular to the isthmus long-axis across its boundaries, the activation wavefront propagated much less uniformly (mean r2= 0.76±0.24) although of similar gradient (mean 0.38±0.23mm/ms). In the opposite direction from the exit, at the isthmus entrance, there was also less uniformity (mean r2= 0.80±0.22) but a larger magnitude gradient (mean 0.50±0.25mm/ms). A theoretical ablation line drawn perpendicular to the last sinus rhythm activation site along the isthmus long-axis was predicted to prevent VT reinduction. Anatomical conduction block occurred in 7/21 experiments, but comprised only small portions of the isthmus lateral boundaries; thus detection of sinus rhythm conduction block alone was insufficient to entirely define the VT isthmus. CONCLUSIONS: Uniform activation with a low magnitude gradient during sinus rhythm is present at the VT isthmus exit location but there is less uniformity across the isthmus lateral boundaries and at isthmus entrance locations. These factors may be useful to verify any proposed VT isthmus location, reducing the need for VT induction to ablate the isthmus. Measured computerized values similar to those determined herein could therefore be assistive to sharpen specificity when applying sinus rhythm mapping to localize EP catheter ablation sites

    Inferring the Tree of Life: chopping a phylogenomic problem down to size?

    Get PDF
    The combination of molecular sequence data and bioinformatics has revolutionized phylogenetic inference over the past decade, vastly increasing the scope of the evolutionary trees that we are able to infer. A recent paper in BMC Biology describing a new phylogenomic pipeline to help automate the inference of evolutionary trees from public sequence databases provides another important tool in our efforts to derive the Tree of Life

    [89Zr]Oxinate4 for long-term in vivo cell tracking by positron emission tomography

    Get PDF
    Purpose 111In (typically as [111In]oxinate3) is a gold standard radiolabel for cell tracking in humans by scintigraphy. A long half-life positron-emitting radiolabel to serve the same purpose using positron emission tomography (PET) has long been sought. We aimed to develop an 89Zr PET tracer for cell labelling and compare it with [111In]oxinate3 single photon emission computed tomography (SPECT). Methods [89Zr]Oxinate4 was synthesised and its uptake and efflux were measured in vitro in three cell lines and in human leukocytes. The in vivo biodistribution of eGFP-5T33 murine myeloma cells labelled using [89Zr]oxinate4 or [111In]oxinate3 was monitored for up to 14 days. 89Zr retention by living radiolabelled eGFP-positive cells in vivo was monitored by FACS sorting of liver, spleen and bone marrow cells followed by gamma counting. Results Zr labelling was effective in all cell types with yields comparable with 111In labelling. Retention of 89Zr in cells in vitro after 24 h was significantly better (range 71 to >90 %) than 111In (43–52 %). eGFP-5T33 cells in vivo showed the same early biodistribution whether labelled with 111In or 89Zr (initial pulmonary accumulation followed by migration to liver, spleen and bone marrow), but later translocation of radioactivity to kidneys was much greater for 111In. In liver, spleen and bone marrow at least 92 % of 89Zr remained associated with eGFP-positive cells after 7 days in vivo. Conclusion [89Zr]Oxinate4 offers a potential solution to the emerging need for a long half-life PET tracer for cell tracking in vivo and deserves further evaluation of its effects on survival and behaviour of different cell types

    The proangiogenic capacity of polymorphonuclear neutrophils delineated by microarray technique and by measurement of neovascularization in wounded skin of CD18-deficient mice

    Get PDF
    Growing evidence supports the concept that polymorphonuclear neutrophils (PMN) are critically involved in inflammation-mediated angiogenesis which is important for wound healing and repair. We employed an oligonucleotide microarray technique to gain further insight into the molecular mechanisms underlying the proangiogenic potential of human PMN. In addition to 18 known angiogenesis-relevant genes, we detected the expression of 10 novel genes, namely midkine, erb-B2, ets-1, transforming growth factor receptor-beta(2) and -beta(3), thrombospondin, tissue inhibitor of metalloproteinase 2, ephrin A2, ephrin B2 and restin in human PMN freshly isolated from the circulation. Gene expression was confi rmed by the RT-PCR technique. In vivo evidence for the role of PMN in neovascularization was provided by studying neovascularization in a skin model of wound healing using CD18-deficient mice which lack PMN infi ltration to sites of lesion. In CD18-deficient animals, neo- vascularization was found to be signifi cantly compromised when compared with wild- type control animals which showed profound neovascularization within the granulation tissue during the wound healing process. Thus, PMN infiltration seems to facilitate inflammation mediated angiogenesis which may be a consequence of the broad spectrum of proangiogenic factors expressed by these cells. Copyright (c) 2006 S. Karger AG, Basel

    SHIFTING THE PARADIGM IN RADIATION SAFETY

    Get PDF
    The current radiation safety paradigm using the linear no-threshold (LNT) model is based on the premise that even the smallest amount of radiation may cause mutations increasing the risk of cancer. Autopsy studies have shown that the presence of cancer cells is not a decisive factor in the occurrence of clinical cancer. On the other hand, suppression of immune system more than doubles the cancer risk in organ transplant patients, indicating its key role in keeping occult cancers in check. Low dose radiation (LDR) elevates immune response, and so it may reduce rather than increase the risk of cancer. LNT model pays exclusive attention to DNA damage, which is not a decisive factor, and completely ignores immune system response, which is an important factor, and so is not scientifically justifiable. By not recognizing the importance of the immune system in cancer, and not exploring exercise intervention, the current paradigm may have missed an opportunity to reduce cancer deaths among atomic bomb survivors. Increased antioxidants from LDR may reduce aging-related non-cancer diseases since oxidative damage is implicated in these. A paradigm shift is warranted to reduce further casualties, reduce fear of LDR, and enable investigation of potential beneficial applications of LDR

    HRS white paper on clinical utilization of digital health technology.

    Get PDF
    This collaborative statement from the Digital Health Committee of the Heart Rhythm Society provides everyday clinical scenarios in which wearables may be utilized by patients for cardiovascular health and arrhythmia management. We describe herein the spectrum of wearables that are commercially available for patients, and their benefits, shortcomings and areas for technological improvement. Although wearables for rhythm diagnosis and management have not been examined in large randomized clinical trials, undoubtedly the usage of wearables has quickly escalated in clinical practice. This document is the first of a planned series in which we will update information on wearables as they are revised and released to consumers
    corecore