5,104 research outputs found

    Decay Phase Cooling and Inferred Heating of M- and X-class Solar Flares

    Full text link
    In this paper, the cooling of 72 M- and X-class flares is examined using GOES/XRS and SDO/EVE. The observed cooling rates are quantified and the observed total cooling times are compared to the predictions of an analytical 0-D hydrodynamic model. It is found that the model does not fit the observations well, but does provide a well defined lower limit on a flare's total cooling time. The discrepancy between observations and the model is then assumed to be primarily due to heating during the decay phase. The decay phase heating necessary to account for the discrepancy is quantified and found be ~50% of the total thermally radiated energy as calculated with GOES. This decay phase heating is found to scale with the observed peak thermal energy. It is predicted that approximating the total thermal energy from the peak is minimally affected by the decay phase heating in small flares. However, in the most energetic flares the decay phase heating inferred from the model can be several times greater than the peak thermal energy.Comment: Published in the Astrophysical Journal, 201

    Using LaX scintillator in a new low-background Compton telescope

    Get PDF
    The ability of Compton telescopes to perform imaging and spectroscopy in space depends directly on the speed and energy resolution of the calorimeter detectors in the telescope. The calorimeter detectors flown on space-borne or balloon-borne Compton telescopes have included NaI(Tl), CsI(Na), HPGe and liquid organic scintillator. By employing LaX scintillators for the calorimeter, one can take advantage of the unique speed and resolving power of the material to improve the instrument sensitivity and simultaneously enhance its spectroscopic performance and thus its imaging performance. We present a concept for a space-borne Compton telescope that employs LaX as a calorimeter and estimate the improvement in sensitivity over past realizations of Compton telescopes. With some preliminary laboratory measurements, we estimate that in key energy bands, typically corrupted with neutron-induced internal nuclear emissions, this design enjoys a twenty-fold improvement in background rejection

    Gas micro-well track imaging detectors for gamma-ray astronomy

    Get PDF
    We describe our program to develop gas micro-well detectors (MWDs) as three-dimensional charged particle trackers for use in advanced gamma-ray telescope concepts. A micro-well detector consists of an array of individual micro-patterned gas proportional counters opposite a planar drift electrode. The well anodes and cathodes may be connected in X and Y strips, respectively, to provide two-dimensional imaging. When combined with transient digitizer electronics, which record the time signature of the charge collected in the wells of each strip, full three-dimensional reconstruction of charged-particle tracks in large gas volumes is possible. Such detectors hold great promise for advanced Compton telescope (ACT) and advanced pair telescope (APT) concepts due to the very precise measurement of charged particle momenta that is possible (Compton recoil electrons and electron-positron pairs, respectively). We present preliminary lab results, including detector fabrication, prototype electronics, and initial detector testing. We also discuss applications to the ACT and APT mission concepts, based on GEANT3 and GEANT4 simulations

    Position Resolution in LaBr3 and LaCl3 Scintillators Using Position-Sensitive Photomultiplier Tubes

    Get PDF
    Advanced scintillator materials such as LaBr3:Ce and LaCl3:Ce hold great promise for future hard X-ray and gamma-ray astrophysics missions due to their high density, high light output, good linearity, and fast decay times. Of particular importance for future space-based imaging instruments, such as coded-aperture telescopes, is the precise spatial location of individual gamma-ray interactions. We have investigated the position and energy resolution achievable within monolithic (5 cm × 5 cm × 1 cm) LaBr3:Ce and LaCl3:Ce crystals using position-sensitive light readout devices, including a position-sensitive photomultiplier tube and a multi-anode photomultiplier tube. We present the results of these tests and discuss the applicability of such advanced scintillators to future high-energy imaging astrophysics missions

    Ethyl and isopropyl 4-ferrocenylbenzoate.

    Get PDF
    The title compounds, [Fe(C5H5)(C14H13O2)] and [Fe(C5H5)- (C15H15O2)], respectively, contain the ferrocenyl 5(C5H4) and phenylene ±C6H4± rings in a nearly coplanar arrangement, with interplanar angles of 6.88 (12) and 10.5 (2), respectively. Molecules of the ethyl ester form dimers through 5(C5H5)CÐ H O C hydrogen bonds, with graph set R22 (20), and, together with Csp3ÐH (C5H5) interactions, generate a one-dimensional column (irregular ladder). Molecules of the isopropyl ester aggregate through 5(C5H5)CÐH (C6H4) interactions

    Plans for the first balloon flight of the gamma-ray polarimeter experiment (GRAPE)

    Get PDF
    We have developed a design for a hard X-ray polarimeter operating in the energy range from 50 to 500 keV. This modular design, known as GRAPE (Gamma-Ray Polarimeter Experiment), has been successfully demonstrated in the lab using partially polarized gamma-ray sources and using fully polarized photon beams at Argonne National Laboratory. In June of 2007, a GRAPE engineering model, consisting of a single detector module, was flown on a high altitude balloon flight to further demonstrate the design and to collect background data. We are currently preparing a much larger balloon payload for a flight in the fall of 2011. Using a large (16-element) array of detector modules, this payload is being designed to search for polarization from known point sources of radiation, namely the Crab and Cygnus X-1. This first flight will not only provide a scientific demonstration of the GRAPE design (by measuring polarization from the Crab nebula), it will also lay the foundation for subsequent long duration balloon flights that will be designed for studying polarization from gamma-ray bursts and solar flares. Here we shall present data from calibration of the first flight module detectors, review the latest payload design and update the predicted polarization sensitivity for both the initial continental US balloon flight and the subsequent long-duration balloon flights

    GRAPE: a balloon-borne gamma-ray polarimeter

    Get PDF
    The Gamma-RAy Polarimeter Experiment (GRAPE) is a concept for an astronomical hard X-ray Compton polarimeter operating in the 50 - 500 keV energy band. The instrument has been optimized for wide-field polarization measurements of transient outbursts from energetic astrophysical objects such as gamma-ray bursts and solar flares. The GRAPE instrument is composed of identical modules, each of which consists of an array of scintillator elements read out by a multi-anode photomultiplier tube (MAPMT). Incident photons Compton scatter in plastic scintillator elements and are subsequently absorbed in inorganic scintillator elements; a net polarization signal is revealed by a characteristic asymmetry in the azimuthal scattering angles. We have constructed a prototype GRAPE module that has been calibrated at a polarized hard X-ray beam and flown on an engineering balloon test flight. A full-scale scientific balloon payload, consisting of up to 36 modules, is currently under development. The first flight, a one-day flight scheduled for 2011, will verify the expected scientific performance with a pointed observation of the Crab Nebula. We will then propose long-duration balloon flights to observe gamma-ray bursts and solar flares

    Scintillator gamma-ray detectors with silicon photomultiplier readouts for high-energy astronomy

    Get PDF
    Space-based gamma-ray detectors for high-energy astronomy face strict constraints of mass, volume, and power, and must endure harsh operating environments. Scintillator materials have a long history of successful operation under these conditions, and new materials offer greatly improved performance in terms of efficiency, time response, and energy resolution. The use of scintillators in space remains constrained, however, by the mass, volume, and fragility of the associated light readout device, typically a vacuum photomultiplier tube (PMT). Recently developed silicon photomultipliers (SiPMs) offer gains and efficiencies similar to those of PMTs, but with greatly reduced mass and volume, high ruggedness, and no high-voltage requirements. We have therefore been investigating the use of SiPM readouts for scintillator gamma-ray detectors, with an emphasis on their suitability for space- and balloonbased instruments for high-energy astronomy. We present our most recent results, including spectroscopy measurements for lanthanum bromide scintillators with SiPM readouts, and pulse-shape discrimination using organic scintillators with SiPM readouts. We also describe potential applications of SiPM readouts to specific highenergy astronomy instrument concepts

    Quasi-Periodic Pulsations during the Impulsive and Decay phases of an X-class Flare

    Full text link
    Quasi-periodic pulsations (QPP) are often observed in X-ray emission from solar flares. To date, it is unclear what their physical origins are. Here, we present a multi-instrument investigation of the nature of QPP during the impulsive and decay phases of the X1.0 flare of 28 October 2013. We focus on the character of the fine structure pulsations evident in the soft X-ray time derivatives and compare this variability with structure across multiple wavelengths including hard X-ray and microwave emission. We find that during the impulsive phase of the flare, high correlations between pulsations in the thermal and non-thermal emissions are seen. A characteristic timescale of ~20s is observed in all channels and a second timescale of ~55s is observed in the non-thermal emissions. Soft X-ray pulsations are seen to persist into the decay phase of this flare, up to 20 minutes after the non-thermal emission has ceased. We find that these decay phase thermal pulsations have very small amplitude and show an increase in characteristic timescale from ~40s up to ~70s. We interpret the bursty nature of the co-existing multi-wavelength QPP during the impulsive phase in terms of episodic particle acceleration and plasma heating. The persistent thermal decay phase QPP are most likely connected with compressive MHD processes in the post-flare loops such as the fast sausage mode or the vertical kink mode.Comment: 7 pages, 4 figures, 1 tabl
    corecore