72 research outputs found
Ion mobility spectrometry for microbial volatile organic compounds: a new identification tool for human pathogenic bacteria
Presently, 2 to 4 days elapse between sampling at infection suspicion and result of microbial diagnostics. This delay for the identification of pathogens causes quite often a late and/or inappropriate initiation of therapy for patients suffering from infections. Bad outcome and high hospitalization costs are the consequences of these currently existing limited pathogen identification possibilities. For this reason, we aimed to apply the innovative method multi-capillary column–ion mobility spectrometry (MCC-IMS) for a fast identification of human pathogenic bacteria by determination of their characteristic volatile metabolomes. We determined volatile organic compound (VOC) patterns in headspace of 15 human pathogenic bacteria, which were grown for 24 h on Columbia blood agar plates. Besides MCC-IMS determination, we also used thermal desorption–gas chromatography–mass spectrometry measurements to confirm and evaluate obtained MCC-IMS data and if possible to assign volatile compounds to unknown MCC-IMS signals. Up to 21 specific signals have been determined by MCC-IMS for Proteus mirabilis possessing the most VOCs of all investigated strains. Of particular importance is the result that all investigated strains showed different VOC patterns by MCC-IMS using positive and negative ion mode for every single strain. Thus, the discrimination of investigated bacteria is possible by detection of their volatile organic compounds in the chosen experimental setup with the fast and cost-effective method MCC-IMS. In a hospital routine, this method could enable the identification of pathogens already after 24 h with the consequence that a specific therapy could be initiated significantly earlier
In-line monitoring of electrolytes and urea during continuous renal replacement therapy
The individualization of dialysis treatment using a customized dialysate composition usually requires a continuous measurement of electrolytes and urea in blood. The current practices are spot measurements of blood samples either with blood gas analyzers or in the laboratory, involving considerable personnel effort. Furthermore, the measured values are time delayed and not available in a continuous fashion. In this paper we investigate an in-line concept for continuous monitoring of important blood parameters such as sodium, potassium, calcium and urea concentrations in blood serum using ion-selective electrodes. This concept is evaluated in a preclinical study with human packed red blood cells as a test medium over a period of 7 h. It has been shown that the electrolytes can be well monitored. In addition, we present first measurements with ion-sensitive field-effect transistors in a miniaturized sensor assembly. Therefore, new low-cost electronics for such ion-sensitive field-effect transistors have been developed
Point-of-care multiplex PCR promises short turnaround times for microbial testing in hospital-acquired pneumonia – an observational pilot study in critical ill patients
BACKGROUND: The early beginning of an adequate antibiotic therapy is crucial in hospital-acquired pneumonia (HAP), but depends on the results of conventional microbiological diagnostics (cMD). It was the aim of this study to evaluate the performance and turnaround times of a new point-of-care multiplex polymerase chain reaction (mPCR) system for rapid identification of pathogens and antibiotic resistance markers. We assessed the applicability of the system under real-life conditions in critical ill patients with HAP. METHODS: We enrolled forty critical ill patients with clinical signs for HAP into an observational study. Two samples of respiratory secretions were collected during one course of aspiration and cMD and mPCR testing (Unyvero, Curetis AG, Holzgerlingen, Germany) were performed immediately. The mPCR device was operated as a point-of-care system at the intensive care unit. We compared turnaround times, results of pathogen identification and results of antibiotic resistance testing of both methods. RESULTS: Mean turnaround times (min-max) were 6.5 h (4.7–18.3 h) for multiplex PCR and 71 h (37.2–217.8 h) for conventional microbiology (final cMD results, incomplete results neglected). 60 % (n = 24) of the mPCR tests were completely valid. Complete test failure occurred in 10 % (n = 4) and partial test failure occurred in 30 % (n = 12). We found concordant results in 45 % (n = 18) and non-concordant results in 45 % (n = 18) of all patients. 55 % (n = 16) of the results were concordant in patients with a clinical pulmonary infection score (CPIS) > 5 (n = 29). Concordant results included three cases of multidrug resistant bacteria. MPCR frequently detected antibiotic resistance markers that were not found by cMD. CONCLUSIONS: Unyvero allowed point-of-care microbial testing with short turnaround times. The performance of the system was poor. However, an improved system with a more reliable performance and an extended microbial panel could be a useful addition to cMD in intensive care medicine. TRIAL REGISTRATION: ClinicalTrials.gov NCT01858974 (registered 16 May 2013
Alignment of retention time obtained from multicapillary column gas chromatography used for VOC analysis with ion mobility spectrometry
Multicapillary column (MCC) ion mobility spectrometers (IMS) are increasingly in demand for medical diagnosis, biological applications and process control. In a MCC-IMS, volatile compounds are differentiated by specific retention time and ion mobility when rapid preseparation techniques are applied, e.g. for the analysis of complex and humid samples. Therefore, high accuracy in the determination of both parameters is required for reliable identification of the signals. The retention time in the MCC is the subject of the present investigation because, for such columns, small deviations in temperature and flow velocity may cause significant changes in retention time. Therefore, a universal correction procedure would be a helpful tool to increase the accuracy of the data obtained from a gas-chromatographic preseparation. Although the effect of the carrier gas flow velocity and temperature on retention time is not linear, it could be demonstrated that a linear alignment can compensate for the changes in retention time due to common minor deviations of both the carrier gas flow velocity and the column temperature around the MCC-IMS standard operation conditions. Therefore, an effective linear alignment procedure for the correction of those deviations has been developed from the analyses of defined gas mixtures under various experimental conditions. This procedure was then applied to data sets generated from real breath analyses obtained in clinical studies using different instruments at different measuring sites for validation. The variation in the retention time of known signals, especially for compounds with higher retention times, was significantly improved. The alignment of the retention time—an indispensable procedure to achieve a more precise identification of analytes—using the proposed method reduces the random error caused by small accidental deviations in column temperature and flow velocity significantly
Multi-capillary column-ion mobility spectrometry (MCC-IMS) as a new method for the quantification of occupational exposure to sevoflurane in anaesthesia workplaces: an observational feasibility study
BACKGROUND: Occupational exposure to sevoflurane has the potential to cause health damage in hospital personnel. Workplace contamination with the substance mostly is assessed by using photoacoustic infrared spectrometry with detection limits of 10 ppbv. Multi-capillary column-ion mobility spectrometry (MCC-IMS) could be an alternative technology for the quantification of sevoflurane in the room air and could be even more accurate because of potentially lower detection limits. The aim of this study was to test the hypothesis that MCC-IMS is able to detect and monitor very low concentrations of sevoflurane (<10 ppbv) and to evaluate the exposure of hospital personnel to sevoflurane during paediatric anaesthesia and in the post anaesthesia care unit (PACU). METHODS: A MCC-IMS device was calibrated to several concentrations of sevoflurane and limits of detection (LOD) and quantification (LOQ) were calculated. Sevoflurane exposure of hospital personnel was measured at two anaesthesia workplaces and time-weighted average (TWA) values were calculated. RESULTS: The LOD was 0.0068 ppbv and the LOQ was 0.0189 ppbv. During paediatric anaesthesia the mean sevoflurane concentration was 46.9 ppbv (8.0 - 314.7 ppbv) with TWA values between 5.8 and 45.7 ppbv. In the PACU the mean sevoflurane concentration was 27.9 ppbv (8.0 – 170.2 ppbv) and TWA values reached from 8.3 to 45.1 ppbv. CONCLUSIONS: MCC-IMS shows a significantly lower LOD and LOQ than comparable methods. It is a reliable technology for monitoring sevoflurane concentrations at anaesthesia workplaces and has a particular strength in quantifying low-level contaminations of sevoflurane. The exposure of the personnel working in these areas did not exceed recommended limits and therefore adverse health effects are unlikely
Long term biventricular support with Berlin Heart Excor in a Septuagenarian with giant-cell myocarditis
Giant-cell myocarditis (GCM) is known as a rare, rapidly progressive, and frequently fatal myocardial disease in young and middle-aged adults. We report about a 76 year old male patient who underwent implantation with a biventricular Berlin Heart Excor system at the age of 74 due to acute biventricular heart failure caused by giant-cell myocarditis. The implantation was without any surgical problems; however, a difficulty was the immunosuppressive therapy after implantation. Meanwhile the patient is 76 years old and lives with circulatory support for about 3 years without major adverse events. Also, in terms of mobility in old age there are no major limitations. It seems that in even selected elderly patients an implantation of a long term support with the biventricular Berlin Heart Excor is a useful therapeutic option with an acceptable outcome
MultiAgency, prospective, exploratory, non-intervention, cohort Study on Human Impact Exposure oNboard high-speed boats (MASHIEN): protocol
Introduction: High-speed boat operations expose personnel to slamming-induced impacts, which can lead to musculoskeletal injuries and cognitive impairments. Despite existing safety measures, regulations and. protocols, the risk of injuries remains significant. The MultiAgency, prospective, exploratory, non-intervention, cohort Study on Human Impact Exposure oNboard high-speed boats study aims to investigate the nature and magnitude of these impacts, their acute and long-term health effects, and potential injury prevention strategies to improve operational safety and performance.
Methods and analysis: This is an ongoing multicentre, prospective, non-intervention, observational cohort study. The first participant was enrolled on 23 August 2024. High-speed boat operators log self-reported pain data via a smartphone app, using a Visual Analogue Scale and pain drawings. Triaxial accelerometers are installed on boat hulls and worn by participants to measure impact exposure. Data analysis assesses correlations between exposure and reported pain, enabling the identification of risk factors and the development of safety guidelines for high-speed boat operations.
Ethics and dissemination: The study has received ethical approval from the relevant ethics committees, including the Swedish Ethics Review Authority (no. 2022-04931-01). All participants will provide informed consent before enrolment. The findings will be disseminated through technical reports, articles in peer-reviewed journals, conference presentations and direct engagement with military and maritime stakeholders to enhance training protocols and safety measures.
Trial registration number: NCT05299736
Ion mobility spectrometry for microbial volatile organic compounds: a new identification tool for human pathogenic bacteria
Identification of volatile compounds from bacteria by spectrometric methods in medicine diagnostic and other areas: current state and perspectives
Abstract Diagnosis of bacterial infections until today mostly relies on conventional microbiological methods. The resulting long turnaround times can lead to delayed initiation of adequate antibiotic therapy and prolonged periods of empiric antibiotic therapy (e.g., in intensive care medicine). Therewith, they contribute to the mortality of bacterial infections and the induction of multidrug resistances. The detection of species specific volatile organic compounds (VOCs) emitted by bacteria has been proposed as a possible diagnostic approach with the potential to serve as an innovative point-of-care diagnostic tool with very short turnaround times. A range of spectrometric methods are available which allow the detection and quantification of bacterial VOCs down to a range of part per trillion. This narrative review introduces the application of spectrometric analytical methods for the purpose of detecting VOCs of bacterial origin and their clinical use for diagnosing different infectious conditions over the last decade. Key Points • Detection of VOCs enables bacterial differentiation in various medical conditions. • Spectrometric methods may function as point-of-care diagnostics in near future.Abstract Diagnosis of bacterial infections until today mostly relies on conventional microbiological methods. The resulting long turnaround times can lead to delayed initiation of adequate antibiotic therapy and prolonged periods of empiric antibiotic therapy (e.g., in intensive care medicine). Therewith, they contribute to the mortality of bacterial infections and the induction of multidrug resistances. The detection of species specific volatile organic compounds (VOCs) emitted by bacteria has been proposed as a possible diagnostic approach with the potential to serve as an innovative point-of-care diagnostic tool with very short turnaround times. A range of spectrometric methods are available which allow the detection and quantification of bacterial VOCs down to a range of part per trillion. This narrative review introduces the application of spectrometric analytical methods for the purpose of detecting VOCs of bacterial origin and their clinical use for diagnosing different infectious conditions over the last decade. Key Points • Detection of VOCs enables bacterial differentiation in various medical conditions. • Spectrometric methods may function as point-of-care diagnostics in near future
Identification of volatile compounds from bacteria by spectrometric methods in medicine diagnostic and other areas: current state and perspectives
Abstract
Diagnosis of bacterial infections until today mostly relies on conventional microbiological methods. The resulting long turnaround times can lead to delayed initiation of adequate antibiotic therapy and prolonged periods of empiric antibiotic therapy (e.g., in intensive care medicine). Therewith, they contribute to the mortality of bacterial infections and the induction of multidrug resistances. The detection of species specific volatile organic compounds (VOCs) emitted by bacteria has been proposed as a possible diagnostic approach with the potential to serve as an innovative point-of-care diagnostic tool with very short turnaround times. A range of spectrometric methods are available which allow the detection and quantification of bacterial VOCs down to a range of part per trillion. This narrative review introduces the application of spectrometric analytical methods for the purpose of detecting VOCs of bacterial origin and their clinical use for diagnosing different infectious conditions over the last decade.
Key Points
• Detection of VOCs enables bacterial differentiation in various medical conditions.
• Spectrometric methods may function as point-of-care diagnostics in near future.
</jats:sec
- …