25 research outputs found

    Multifocal ERG in patients treated with low-dose tamoxifen

    Get PDF
    PURPOSE: Tamoxifen, an antiestrogen, has been used as an effective therapeutic agent in the treatment of breast cancer. The drug has been shown to cause ocular toxic effects. The purpose of this study was to determine possible central retinal toxicity by multifocal electroretinograms (mfERGs) in a cohort of patients treated with low-dose tamoxifen (20 mg/day) for breast cancer. METHODS: Multifocal electroretinograms of the central 30 degrees of the retina were obtained of 3 different groups: Experimental group - 15 females (41-59 years, mean 48.6 ± 4.5) with normal fundus, treated with low-dose tamoxifen for 1 to 55 months. Control group - 6 females (30-76 years, mean 49.9 ± 18.8) with previous breast cancer diagnosis who had not received tamoxifen as treatment until ERG testing. Normal control group - 15 normal female volunteers (30-71 years, mean 47.7 ± 12.9). The multifocal amplitude and latency for N1-P1 were measured and statistically analyzed (one-way ANOVA). RESULTS: Mean amplitudes N1-P1 (nV/deg²) were comparable for responses of different eccentricity (0 to 25 degrees). There was no statistically significant difference for implicit time of N1 and P1 (ms) in multifocal electroretinograms between the 3 groups. CONCLUSIONS: Low-dose tamoxifen showed no retinotoxic effect in this small group of women with breast cancer. Follow-up investigation could provide a better understanding of these effects.OBJETIVO: O tamoxifeno é um antiestrógeno utilizado como agente terapêutico eficaz no câncer de mama. A droga pode causar efeitos tóxicos oculares em dosagens altas. O objetivo deste estudo foi determinar possíveis efeitos retino-tóxicos centrais usando o eletrorretinograma multifocal (mfERG) em grupo de pacientes tratadas com baixa dosagem de tamoxifeno (20 mg/dia) após cirurgia do câncer de mama. MÉTODOS: O eletrorretinograma multifocal (mfERG) de 30 graus centrais da retina foi obtido em 3 diferentes grupos: Grupo experimental - 15 mulheres (41-59 anos, média 48,6 ± 4,5) com fundo de olho normal, tratadas com tamoxifeno em baixa dosagem por 1 a 55 meses. Grupo controle - 6 mulheres (30 -76 anos, média 49,9±18,8) com diagnóstico prévio de câncer de mama que não receberam tratamento com tamoxifeno até o teste do eletrorretinograma multifocal. Grupo controle normal - 15 voluntárias normais (30-71 anos, média 47,7 ± 12,9). A amplitude e a latência de eletrorretinograma multifocal para N1-P1 foram analisados estatisticamente (análise de variância de uma via). RESULTADOS: As amplitudes médias N1-P1 (nV/grau²) foram comparáveis para respostas de diferentes excentricidades (0 a 25 graus) nos três grupos. Não houve diferença estatisticamente significativa para a latência de N1 e P1 (ms) do eletrorretinograma multifocal entre os 3 grupos. CONCLUSÕES: O tratamento com baixa dosagem de tamoxifeno não mostrou efeitos retino-tóxicos em pequeno grupo de mulheres após cirurgia do câncer de mama. Investigação seriada proporcionará melhor compreensão desses efeitos.Universidade Federal de São Paulo (UNIFESP) Departamento de OftalmologiaUniversidade Federal de São Paulo (UNIFESP) Departamento de Oftalmologia Setor de Eletrofisiologia Visual ClínicaHospital do Câncer - AC. CamargoUNIFESP, Depto. de OftalmologiaUNIFESP, Depto. de Oftalmologia Setor de Eletrofisiologia Visual ClínicaSciEL

    Visual acuity and rod function in patients with retinitis pigmentosa

    Get PDF
    PURPOSE: To investigate visual acuity and rod function, and correlate them to different clinical parameters in patients with retinitis pigmentosa (RP). METHODS: A cohort of 199 patients with retinitis pigmentosa (110 males and 89 females), aged 6-79 years (mean = 36.8±17.5) had their monocular visual acuity measured by the ETDRS chart and rod function assessed by full-field electroretinogram and dark-adapted thresholds. The distribution of different genetic subtypes of retinitis pigmentosa was 20.3% autosomal dominant, 14.2% X - linked, 24.2% autosomal recessive and 41.3% isolated. History of consanguinity was found in 41 (20.6%) patients. Forty-one patients (20.6%) were 20 years old or less, 77 (38.6%) ranged from 21 - 40 years, 61 (30.7%) from 41 - 60 years, and 20 (10.1%) were 61 years or older. Peak-to-peak amplitude and b-wave implicit time were measured and statistically analyzed (one-way ANOVA). Pearson correlation was performed between rod amplitude and dark-adapted thereshold and rod amplitude and visual acuity. RESULTS: Analyzing the visual acuity data according to genetic subtypes, without considering age, showed that as a group, patients with autosomal recessive and isolated retinitis pigmentosa have less severe impairment of visual acuity, than those with X-linked retinitis pigmentosa. Nyctalopia begun earlier in X-linked groups, compared with the remaining groups (p=0.011). A negative correlation was found between dark-adapted thereshold and scotopic rod amplitude (Pearson correlation coefficient = - 0.772 and P =0.000). There were no significant relationships between visual acuity and rod response by electroretinogram (Pearson correlation coefficient = 0.0815 and P = 0.286), P > 0.050. CONCLUSIONS: In a cohort of retinitis pigmentosa patients, 31.2% had vision of 20/40 or better. Rod function loss was highly correlated when assessed electrophysiologically (ERG) and psychophysically (dark-adapted thershold). No correlation was found between rod response measured by electroretinogram and visual acuity.OBJETIVO: Investigar a acuidade visual e a função dos bastonetes e correlacioná-las com diferentes parâmetros clínicos freqüentemente observados em pacientes com retinose pigmentária (RP). MÉTODOS: Participaram deste estudo 199 pacientes com retinose pigmentária (110 homens e 89 mulheres), com idades variando entre 6 e 79 anos (média = 36,8±17,5), para avaliação da acuidade visual e da função de bastonetes obtidas pelo eletrorretinograma de campo total (ERG) e limiar de adaptação ao escuro (LAE). A distribuição dos diferentes subtipos genéticos da retinose pigmentária foi de 20,3% autossômica dominante, 14,2% ligada ao X , 24,2% autossômica recessiva e 41,3% isolada. Consangüinidade familiar positiva foi encontrada em 41 (20,6%) pacientes. Com relação à idade, 41 pacientes (20,6%) apresentavam idade inferior a 20 anos, 77 (38,6%) entre 21 - 40 anos, 61 (30,7%) entre 41 - 60 anos, e 20 (10,1%) apresentaram idade superior a 61 anos. A amplitude pico a pico e tempo de culminação da onda-b foram medidos e posteriormente analisados (ANOVA de uma via). A correlação de Pearson foi calculada entre amplitudes de bastonetes e o limiar de adaptação ao escuro e amplitude de bastonetes e acuidade visual. RESULTADOS: Analisando a acuidade visual de acordo com os sub-grupos de retinose pigmentária, sem levar em consideração a idade, obser-vamos que os pacientes com retinose pigmentária autossômica dominante, retinose pigmentária autossômica recessiva e retinose pigmentária isolada têm comprometimento da acuidade visual menor quando comparado a retinose pigmentária ligada ao X. A nictalopia teve início mais precocemente nos pacientes do subtipo retinose pigmentária ligada ao X quando comparada aos restantes (P = 0,0011). Correlação negativa foi obtida entre a perda de função de bastonetes medida pelo eletrorretinograma de campo total e pelo limiar de adaptação ao escuro (coeficiente de correlação de Pearson = - 0,772, P = 0,286, P> 0,050). CONCLUSÃO: Neste grupo de pacien-te com retinose pigmentária, 31,2% tiveram acuidade visual de 20/40 ou superior. A perda de função de bastonetes foi altamente correlacionada quando avaliada eletrofisiologicamente pelo eletrorretinograma de campo total e psicofisicamente pelo limiar de adaptação ao escuro. Não houve correlação entre a perda de função de bastonetes medida pelo eletrorretinograma e a acuidade visual.Universidade Federal de São Paulo (UNIFESP) Departamento de OftalmologiaUniversidade Federal de São Paulo (UNIFESP) Departamento de Oftalmologia Setor de Eletrofisiologia Visual ClínicaUniversidade Federal de São Paulo (UNIFESP) Departamento de Oftalmologia Laboratório de Eletrofisiologia Visual ClínicaUNIFESP, Depto. de OftalmologiaUNIFESP, Depto. de Oftalmologia Setor de Eletrofisiologia Visual ClínicaUNIFESP, Depto. de Oftalmologia Laboratório de Eletrofisiologia Visual ClínicaSciEL

    Visual acuity and full-field electroretinography in patients with Usher's syndrome

    Get PDF
    PURPOSE: Usher's syndrome (US) is a group of genetically distinct autossomal conditions, characterized by sensorineural hearing loss accompanied by a retinal dystrophy indistinguishable from retinitis pigmentosa (RP). The purpose of this study was to analyze full-field electroretinography (ERG) and visual acuity (VA) among patients with type I and II Usher's syndrome. METHODS: Electroretinography responses and visual acuity were studied in 22 patients (mean age at test = 26.8±16.8 years). Seventeen patients had SU type I and 5 patients were diagnosed as Usher's syndrome type II. RESULTS: Mean visual acuity was 0.9 logMAR (20/160, Snellen equivalent) for patients with Usher's syndrome type I and 0.4 logMAR (20/50, Snellen equivalent) for patients with Usher's syndrome type II. Scotopic rod and maximal responses were non-detectable in both groups. Mean amplitude for oscillatory potentials was 14.5 µV ±6.1 in Usher's syndrome type I and 12.6 µV±5.2 in Usher's syndrome type II. Cone responses were non-detectable in 95% of the patients with Usher's syndrome I and in 100% of patients with Usher's syndrome II. Mean amplitude for 30 Hz flicker photopic cone response was 3.1 µV±4.1 for Usher's syndrome type I and 1.0 µV±0.6 for type II with mean implicit time of 34.0 ms±6.2 (US I) and 35.8 ms±3.1 (type II). CONCLUSIONS: Visual acuity was relatively preserved in both groups, however Usher's syndrome II group showed better visual acuity results. Electroretinography findings were severely reduced in both groups, with most patients showing non-detectable rod and cone responses.A síndrome de Usher (SU) é doença autossômica recessiva caracterizada por perda auditiva neuro-sensorial acompanhada de retinose pigmentária (RP). OBJETIVO: Analisar a eletrorretinografia de campo total (ERG) e a acuidade visual (AV) em pacientes com síndrome de Usher tipos I e II. MÉTODOS: Foram estudadas as respostas da eletrorretinografia de campo total e a acuidade visual de 22 pacientes (idade média = 26,8±16,8 anos). Destes, 17 tinham síndrome de Usher tipo I e 5 tinham síndrome de Usher tipo II. RESULTADOS: A acuidade visual média do grupo síndrome de Usher I foi de 0,9 logMAR (20/160, equivalente de Snellen) e do grupo síndrome de Usher II de 0,4 logMAR (20/50, equivalente de Snellen). As respostas dos bastonetes e as máximas respostas mostraram-se não detectáveis nos dois grupos. A amplitude média dos potenciais oscilatórios foi de 14,5 µV±6,1 na síndrome de Usher I e na síndrome de Usher II de 12,6 µV±5,2. As respostas de cones foram não detectáveis em 95% dos pacientes com síndrome de Usher I e em 100% dos pacientes com síndrome de Usher II. A amplitude média do flicker a 30 Hz nos pacientes com síndrome de Usher I foi de 3,1 µV±4,1 e do tempo de culminação de 34,0ms±6,2; nos pacientes com síndrome de Usher II a média de amplitude foi de 1,0 mV±0,6 e do tempo de culminação de 35,8 ms±3,1. CONCLUSÃO: A acuidade visual mostrou-se relativamente preservada nos dois grupos, porém com melhores resultados no grupo de síndrome de Usher II. Os achados eletrorretinográficos mostraram-se grandemente reduzidos em ambos os grupos, com a maioria dos pacientes apresentando respostas não detectáveis de bastonetes e cones.Universidade Federal de São Paulo (UNIFESP) Departamento de OftalmologiaUniversidade Federal de São Paulo (UNIFESP) Departamento de Oftalmologia Laboratório de Eletrofisiologia Visual ClínicaUniversidade Federal de São Paulo (UNIFESP)UNIFESP, Depto. de OftalmologiaUNIFESP, Depto. de Oftalmologia Laboratório de Eletrofisiologia Visual ClínicaUNIFESPSciEL

    Ambliopia no pós-operatório de catarata congênita unilateral operada após seis semanas de vida

    Get PDF
    PURPOSE: To determine interocular grating acuity difference in children treated for unilateral infantile cataract. METHODS: A group of 27 children previously treated for unilateral infantile cataract, had their monocular visual acuity measured by sweep visual evoked potentials. Interocular grating acuity difference was calculated as the absolute subtraction of monocular acuity scores. Lens status, opacity severity and eye alignment were considered for analysis. RESULTS: Mean interocular grating acuity difference obtained from unilateral cataract patients was 0.58 ± 0.20 logMAR. This result was significantly larger than 0.10 logMAR used as normative data. Children with severe opacities had a more pronounced amblyopia than the moderate ones. No significant correlation between amblyopia and strabismus or aphakia was found. CONCLUSIONS: Interocular acuity difference in this group of unilateral congenital cataract was more pronounced than previous reports, mainly because of delay in diagnosis, surgery and optical correction.OBJETIVOS: Determinar a diferença interocular da acuidade visual de resolução de grades em crianças operadas de catarata congênita unilateral. MÉTODOS: Um grupo de 27 pacientes operados de catarata congênita unilateral tiveram mensurada sua acuidade visual monocular pelo potencial visual evocado de varredura. A diferença interocular foi calculada pela subtração absoluta das acuidades monoculares. A intensidade da opacificação, implante ou não de lente intraocular e presença de estrabismo foram consideradas para análise. RESULTADOS: A média da diferença interocular foi de 0,58 ± 0,20 logMAR. Esse resultado foi significantemente maior que 0,10 logMAR, valor considerado como média normal nos estudos normativos. Crianças com opacidades intensas tiveram ambliopia mais pronunciada que os casos moderados. Não houve correlação significante entre a intensidade da ambliopia com estrabismo e afacia. CONCLUSÕES: A diferença interocular nesse grupo de crianças operadas de catarata congênita unilateral foi muito mais pronunciada que artigos prévios, provavelmente pelos atrasos no diagnóstico, intervenção cirúrgica e correção óptica.Santa Casa de São Paulo Setor de Estrabismo e Neuro-OftalmologiaUniversidade Federal de São Paulo (UNIFESP) Setor de Eletrofisiologia Visual ClínicaUNIFESP Setor de Eletrofisiologia Visual ClínicaUNIFESPSanta Casa de São Paulo Departamento de Oftalmologia Setor de Catarata CongênitaUNIFESP Departamento de Oftalmologia Setor de Catarata CongênitaUNIFESP Departamento de OftalmologiaUNIFESP, Setor de Eletrofisiologia Visual ClínicaUNIFESP, Setor de Eletrofisiologia Visual ClínicaUNIFESP, Depto. de Oftalmologia Setor de Catarata CongênitaUNIFESP, Depto. de OftalmologiaSciEL

    Eye care services evaluation in a low-income urban population of São Paulo City - Brazil

    Get PDF
    PURPOSE: To evaluate eye care services from the user's perspective in a low income population from the east zone of the city of São Paulo - Brazil. METHODS: A household survey was performed using cluster sampling in three low income districts of the city of São Paulo - Brazil. From July/2004 to January/2005, 1055 interviews with an adult household representative were carried and an eye care system responsiveness questionnaire was administered through individual interview. RESULTS: 71.56% of the participants were women. Respondents' age ranged from 18 to 92 years (41.42 ± 15.67 years). Regarding schooling, 525 (49.77%) had four years or less; 489 (46.35%) between five and eleven years, 40 (3.79%) had eleven or more years of study. Eye care services need was reported as 712 (67.49%) declaring themselves or someone else of the household needing and obtaining services and 135 (12.80%) had never needed eye care. The most frequently cited barriers to obtain the eye care service by respondents was cost (77.29%), followed by unsuccessful attempt to obtain eye care (42.21%). General satisfaction for the criteria contained in the questionnaire was 63.37%. In the 36.63% dissatisfied respondents, the most frequently cited claim was the amount of time waited before consultation. CONCLUSION: The main barriers to obtain eye care services were cost of medical appointment and lack of access to the services. 63.37% of the individuals in need who had received eye care in last 12 months were satisfied with the service provided.OBJETIVO: Avaliar os serviços de assistência ocular do ponto de vista do usuário em população de baixa renda, na zona leste da cidade de São Paulo - Brasil. MÉTODOS: Estudo realizado por meio de inquérito domiciliar em uma amostra por conglomerados em três distritos de baixa renda da cidade de São Paulo - Brasil. No período de julho/2004 a janeiro/2005 foram realizadas 1.055 entrevistas com um representante do domicílio, sendo aplicado o questionário de responsividade aos serviços de assistência ocular em entrevista individual. RESULTADOS: Dos participantes, 71,56% eram mulheres. A idade dos respondentes variou de 18 a 92 anos (41,42 ± 15,67 anos). Quanto à escolaridade, 525 (49,77%) tinham 4 anos ou menos; 489 (46,35%) entre 5 e 11 anos; 40 (3,79%) 11 ou mais anos de estudo. Quanto à necessidade de utilização dos serviços de assistência ocular: 712 (67,49%) relataram que algum morador do seu domicílio necessitou e obteve assistência ocular e 135 (12,80%) nunca precisaram de assistência ocular. A barreira mais frequentemente citada para obtenção dos serviços de assistência ocular pelos respondentes foi o custo da consulta (77,29%) seguida de tentativa frustrada de obtenção da assistência ocular (42,21%). A frequência de avaliações positivas para os critérios contidos no questionário foi de 63,37%. Dos 36,63% respondentes insatisfeitos, o tempo de espera na sala de recepção dos serviços de assistência ocular foi o fator mais frequentemente apontado. CONCLUSÃO: As principais barreiras para obter assistência ocular foram o custo da consulta e a falta de acesso aos serviços, 63,37% dos indivíduos que necessitaram e obtiveram assistência ocular nos últimos 12 meses mostraram-se satisfeitos.Universidade Federal de São Paulo (UNIFESP) Departamento de Oftalmologia Setor de Eletrofisiologia Visual ClínicaUNIFESP Departamento de OftalmologiaUNIFESPUNIFESP Departamento de Oftalmologia Setor de Eletrofisiologia Visual ClínicaUNIFESP, Depto. de Oftalmologia Setor de Eletrofisiologia Visual ClínicaUNIFESP, Depto. de OftalmologiaUNIFESP, Depto. de Oftalmologia Setor de Eletrofisiologia Visual ClínicaSciEL

    Full-field electroretinogram recorded with skin electrodes in normal adults

    No full text
    Purpose: Alternative recording methods have been tested to allow the electroretinogram (ERG) recording in uncooperative patients and/or patients with palpebral alterations, including recordings with skin electrodes. The purpose of this study was to compare ERG recorded with skin electrodes and well-established microfiber electrodes and to determine normative values of ERG parameters for recording with skin electrodes. Methods: Fifty healthy volunteers (17-26 yearsmean 20.63 +/- 2.01 years) participated in the study. A gold disk skin electrode was placed on the lower orbital rim of a randomly chosen eye. On the contralateral eye, a microfiber electrode was positioned in the lower conjunctival sac. Gold disc electrodes were positioned at the ipsilateral outer canthus of both eyes acting as reference electrodes for the creation of a potential difference. Two ground electrodes were placed on the lobe of each ear. ERGs were recorded according to the International Society of Clinical Electrophysiology Visual (ISCEV) protocol using the VERIS 5.1.9 system for data acquisition and analysis. Results: Both types of electrodes showed similar wave response morphologies. The implicit time of responses between the two electrodes was comparable. On peak-to-peak amplitude, skin electrode recordings showed an amplitude reduction of 61.4% for rod responses, 61.5% for maximal responses, 46.2% for oscillatory potentials, 57.4% for cone responses, and 54.4% for 30Hz-flicker responses, when compared with microfiber electrode recordings. Based on these findings, normative values for peak-to-peak amplitude and implicit time to be used as a reference for ERGs recorded with skin electrodes were determined. Conclusions: ERGs recorded with skin electrodes presented lower peak-to-peak amplitude compared with microfiber electrodes. However, using appropriate normative values, skin electrodes may be useful for specific target populations such as uncooperative infants and/or patients with ocular surface alterations.Univ Fed Sao Paulo UNIFESP, Lab Eletrofisiol Visual Clin, Dept Oftalmol & Ciencias Visuais, Escola Paulista Med EPM, Sao Paulo, SP, BrazilLaboratório de Eletrofisiologia Visual Clínica, Departamento de Oftalmologia e Ciências Visuais, Escola Paulista de Medicina (EPM), Universidade Federal de São Paulo (UNIFESP), São Paulo, SP, BrazilWeb of Scienc

    Age norms for monocular grating acuity measured by sweep-VEP in the first three years of age Estudo normativo de acuidade visual de resolução de grades medido pelo PVE de varredura nos três primeiros anos de vida

    Get PDF
    PURPOSE: To determine age norms for grating visual acuity and interocular acuity differences measured by the sweep-visually evoked potentials (VEP) technique in the first three years of life. METHODS: Monocular grating visual acuity was measured using the sweep-VEP in 67 healthy normal infants and children in the first 36 months of life. RESULTS: Sweep-VEP grating acuity ranged from 0.80 logMAR (20/125 Snellen equivalent) in the first month of life to 0.06 logMAR (20/20 Snellen equivalent) at 36 months of age. Lower normal limits (95th percentile limit) ranged from 0.95 logMAR (20/180) to 0.12 logMAR (20/25) with a progression of approximately 3 octaves in the first 36 months of age. The largest acceptable interocular acuity difference for clinical purposes was 0.10 logMAR. CONCLUSIONS: Age norms for grating acuity along with interocular acuity differences were determined using the sweep-VEP technique. These norms should be incorporated in clinical practice for precise diagnosis of visual status in infants and preverbal children.<br>OBJETIVOS: Propor valores normativos de acuidade visual de grades e sua respectiva diferença interocular medidas pelo potencial visual evocado de varredura nos primeiros três anos de vida. MÉTODOS: Foram avaliadas 67 crianças sadias, sem doenças oculares, que tiveram a acuidade visual medida pelos potenciais evocados visuais de varredura. RESULTADOS: A acuidade visual média variou de 0,80 logMAR (equivalente de Snellen de 20/125) no primeiro mês de vida a 0,06 logMAR (equivalente de Snellen de 20/20) aos 36 meses. Os limites normais inferiores (percentil 95%) variaram de 0,95 logMAR (20/180) a 0,12 logMAR (20/25) com progressão de aproximadamente 3 oitavas nos primeiros 36 meses de vida. A diferença interocular máxima aceitável foi de 0,10 logMAR. CONCLUSÕES: Os valores normativos de acuidade visual e de diferença interocular de acuidade foram obtidos pela técnica do potencial visual evocado de varredura. Propõe-se sua adoção na prática clínica para diagnóstico preciso do estado visual de bebês e de crianças pré-verbais
    corecore