1,036 research outputs found

    Early infant feeding and adiposity risk: from infancy to adulthood

    Get PDF
    Introduction: Systematic reviews suggest that a longer duration of breast-feeding is associated with a reduction in the risk of later overweight and obesity. Most studies examining breast-feeding in relation to adiposity have not used longitudinal analysis. In our study, we aimed to examine early infant feeding and adiposity risk in a longitudinal cohort from birth to young adulthood using new as well as published data. Methods: Data from the Western Australian Pregnancy Cohort (Raine) Study in Perth, W.A., Australia, were used to examine associations between breast-feeding and measures of adiposity at 1, 2, 3, 6, 8, 10, 14, 17, and 20 years. Results: Breast-feeding was measured in a number of ways. Longer breast-feeding (in months) was associated with reductions in weight z-scores between birth and 1 year (β = -0.027; p \u3c 0.001) in the adjusted analysis. At 3 years, breast-feeding for \u3c4 months increased the odds of infants experiencing early rapid growth (OR 2.05; 95% CI 1.43-2.94; p \u3c 0.001). From 1 to 8 years, children breast-fed for ≤4 months compared to ≥12 months had a significantly greater probability of exceeding the 95th percentile of weight. The age at which breast-feeding was stopped and a milk other than breast milk was introduced (introduction of formula milk) played a significant role in the trajectory of the BMI from birth to 14 years; the 4-month cutoff point was consistently associated with a higher BMI trajectory. Introduction of a milk other than breast milk before 6 months compared to at 6 months or later was a risk factor for being overweight or obese at 20 years of age (OR 1.47; 95% CI 1.12-1.93; p = 0.005). Discussion: Breast-feeding until 6 months of age and beyond should be encouraged and is recommended for protection against increased adiposity in childhood, adolescence, and young adulthood. Adverse long-term effects of early growth acceleration are fundamental in later overweight and obesity. Formula feeding stimulates a higher postnatal growth velocity, whereas breast-feeding promotes slower growth and a reduced likelihood of overweight and obesity. Biological mechanisms underlying the protective effect of breast-feeding against obesity are based on the unique composition and metabolic and physiological responses to human milk

    Coronary microvascular ischemia in hypertrophic cardiomyopathy - a pixel-wise quantitative cardiovascular magnetic resonance perfusion study.

    Get PDF
    BACKGROUND: Microvascular dysfunction in HCM has been associated with adverse clinical outcomes. Advances in quantitative cardiovascular magnetic resonance (CMR) perfusion imaging now allow myocardial blood flow to be quantified at the pixel level. We applied these techniques to investigate the spectrum of microvascular dysfunction in hypertrophic cardiomyopathy (HCM) and to explore its relationship with fibrosis and wall thickness. METHODS: CMR perfusion imaging was undertaken during adenosine-induced hyperemia and again at rest in 35 patients together with late gadolinium enhancement (LGE) imaging. Myocardial blood flow (MBF) was quantified on a pixel-by-pixel basis from CMR perfusion images using a Fermi-constrained deconvolution algorithm. Regions-of-interest (ROI) in hypoperfused and hyperemic myocardium were identified from the MBF pixel maps. The myocardium was also divided into 16 AHA segments. RESULTS: Resting MBF was significantly higher in the endocardium than in the epicardium (mean ± SD: 1.25 ± 0.35 ml/g/min versus 1.20 ± 0.35 ml/g/min, P < 0.001), a pattern that reversed with stress (2.00 ± 0.76 ml/g/min versus 2.36 ± 0.83 ml/g/min, P < 0.001). ROI analysis revealed 11 (31%) patients with stress MBF lower than resting values (1.05 ± 0.39 ml/g/min versus 1.22 ± 0.36 ml/g/min, P = 0.021). There was a significant negative association between hyperemic MBF and wall thickness (β = −0.047 ml/g/min per mm, 95% CI: −0.057 to −0.038, P < 0.001) and a significantly lower probability of fibrosis in a segment with increasing hyperemic MBF (odds ratio per ml/g/min: 0.086, 95% CI: 0.078 to 0.095, P = 0.003). CONCLUSIONS: Pixel-wise quantitative CMR perfusion imaging identifies a subgroup of patients with HCM that have localised severe microvascular dysfunction which may give rise to myocardial ischemia

    Safety of an intravenous formulation of lamotrigine

    Get PDF
    AbstractPurposeIntravenous (IV) formulations are useful when treating patients where oral administration is not possible and to study certain pharmacokinetic parameters such as bioavailability. We developed a stable-labeled IV formulation of lamotrigine (LTG) for studying pharmacokinetics in epilepsy patients.MethodsStable-labeled IV LTG was given to 20 persons with epilepsy (6 men; 14 women) with a mean age of 34.8 years (SD 11.7). A 50mg dose of LTG (stable labeled) was given intravenously and replaced 50mg of the regular morning oral dose of LTG (unlabeled, commercially available formulation).ResultsNo significant changes in blood pressure, heart rate, or adverse events including rash were attributed to administration of a 50-mg dose of the intravenous LTG formulation.ConclusionOur results show that LTG base that is complexed with 2-hydroxypropyl-β-cyclodextrin and stable-labeled can be given safely as a tracer replacement dose

    The energy budget in Rayleigh-Benard convection

    Full text link
    It is shown using three series of Rayleigh number simulations of varying aspect ratio AR and Prandtl number Pr that the normalized dissipation at the wall, while significantly greater than 1, approaches a constant dependent upon AR and Pr. It is also found that the peak velocity, not the mean square velocity, obeys the experimental scaling of Ra^{0.5}. The scaling of the mean square velocity is closer to Ra^{0.46}, which is shown to be consistent with experimental measurements and the numerical results for the scaling of Nu and the temperature if there are strong correlations between the velocity and temperature.Comment: 5 pages, 3 figures, new version 13 Mar, 200

    Right atrial area and right ventricular outflow tract akinetic length predict sustained tachyarrhythmia in repaired tetralogy of Fallot

    Get PDF
    AIMS: Repaired tetralogy of Fallot (rtoF) patients are at risk of atrial or ventricular tachyarrhythmia and sudden cardiac death. Risk stratification for arrhythmia remains difficult. We investigated whether cardiac anatomy and function predict arrhythmia. METHODS: One-hundred-and-fifty-four adults with rtoF, median age 30.8 (21.9–40.2) years, were studied with a standardised protocol including cardiovascular magnetic resonance (CMR) and prospectively followed up over median 5.6 (4.6–7.0) years for the pre-specified endpoints of new-onset atrial or ventricular tachyarrhythmia (sustained ventricular tachycardia/ventricular fibrillation). RESULTS: Atrial tachyarrhythmia (n = 11) was predicted by maximal right atrial area indexed to body surface area (RAAi) on four-chamber cine-CMR (Hazard ratio 1.17, 95% Confidence Interval 1.07–1.28 per cm(2)/m(2); p = 0.0005, survival receiver operating curve; ROC analysis, area under curve; AUC 0.74 [0.66–0.81]; cut-off value 16 cm(2)/m(2)). Atrial arrhythmia-free survival was reduced in patients with RAAi ≥ 16 cm(2)/m(2) (logrank p = 0.0001). Right ventricular (RV) restrictive physiology on echocardiography (n = 38) related to higher RAAi (p = 0.02) and had similar RV dilatation compared with remaining patients. Ventricular arrhythmia (n = 9) was predicted by CMR RV outflow tract (RVOT) akinetic area length (Hazard ratio 1.05, 95% Confidence Interval 1.01–1.09 per mm; p = 0.003, survival ROC analysis, AUC 0.77 [0.83–0.61]; cut-off value 30 mm) and decreased RV ejection fraction (Hazard ratio 0.93, 95% Confidence Interval 0.87–0.99 per %; p = 0.03). Ventricular arrhythmia-free survival was reduced in patients with RVOT akinetic region length > 30 mm (logrank p = 0.02). CONCLUSION: RAAi predicts atrial arrhythmia and RVOT akinetic region length predicts ventricular arrhythmia in late follow-up of rtoF. These are simple, feasible measurements for inclusion in serial surveillance and risk stratification of rtoF patients

    Comparison of 3 T and 1.5 T for T2* magnetic resonance of tissue iron.

    Get PDF
    BACKGROUND: T2* magnetic resonance of tissue iron concentration has improved the outcome of transfusion dependant anaemia patients. Clinical evaluation is performed at 1.5 T but scanners operating at 3 T are increasing in numbers. There is a paucity of data on the relative merits of iron quantification at 3 T vs 1.5 T. METHODS: A total of 104 transfusion dependent anaemia patients and 20 normal volunteers were prospectively recruited to undergo cardiac and liver T2* assessment at both 1.5 T and 3 T. Intra-observer, inter-observer and inter-study reproducibility analysis were performed on 20 randomly selected patients for cardiac and liver T2*. RESULTS: Association between heart and liver T2* at 1.5 T and 3 T was non-linear with good fit (R (2) = 0.954, p < 0.001 for heart white-blood (WB) imaging; R (2) = 0.931, p < 0.001 for heart black-blood (BB) imaging; R (2) = 0.993, p < 0.001 for liver imaging). R2* approximately doubled between 1.5 T and 3 T with linear fits for both heart and liver (94, 94 and 105 % respectively). Coefficients of variation for intra- and inter-observer reproducibility, as well as inter-study reproducibility trended to be less good at 3 T (3.5 to 6.5 %) than at 1.5 T (1.4 to 5.7 %) for both heart and liver T2*. Artefact scores for the heart were significantly worse with the 3 T BB sequence (median 4, IQR 2-5) compared with the 1.5 T BB sequence (4 [3-5], p = 0.007). CONCLUSION: Heart and liver T2* and R2* at 3 T show close association with 1.5 T values, but there were more artefacts at 3 T and trends to lower reproducibility causing difficulty in quantifying low T2* values with high tissue iron. Therefore T2* imaging at 1.5 T remains the gold standard for clinical practice. However, in centres where only 3 T is available, equivalent values at 1.5 T may be approximated by halving the 3 T tissue R2* with subsequent conversion to T2*

    T1 at 1.5T and 3T compared with conventional T2* at 1.5T for cardiac siderosis

    Get PDF
    Background: Myocardial black blood (BB) T2* relaxometry at 1.5T provides robust, reproducible and calibrated non-invasive assessment of cardiac iron burden. In vitro data has shown that like T2*, novel native Modified Look-Locker Inversion recovery (MOLLI) T1 shortens with increasing tissue iron. The relative merits of T1 and T2* are largely unexplored. We compared the established 1.5T BB T2* technique against native T1 values at 1.5T and 3T in iron overload patients and in normal volunteers. Methods: A total of 73 subjects (42 male) were recruited, comprising 20 healthy volunteers (controls) and 53 patients (thalassemia major 22, sickle cell disease 9, hereditary hemochromatosis 9, other iron overload conditions 13). Single mid-ventricular short axis slices were acquired for BB T2* at 1.5T and MOLLI T1 quantification at 1.5T and 3T. Results: In healthy volunteers, median T1 was 1014 ms (full range 939–1059 ms) at 1.5T and modestly increased to 1165ms (full range 1056–1224 ms) at 3T. All patients with significant cardiac iron overload (1.5T T2* values <20 ms) had T1 values <939 ms at 1.5T, and <1056 ms at 3T. Associations between T2* and T1 were found to be moderate with y =377 · x0.282 at 1.5T (R2 = 0.717), and y =406 · x0.294 at 3T (R2 = 0.715). Measures of reproducibility of T1 appeared superior to T2*. Conclusions: T1 mapping at 1.5T and at 3T can identify individuals with significant iron loading as defined by the current gold standard T2* at 1.5T. However, there is significant scatter between results which may reflect measurement error, but it is also possible that T1 interacts with T2*, or is differentially sensitive to aspects of iron chemistry or other biology. Hurdles to clinical implementation of T1 include the lack of calibration against human myocardial iron concentration, no demonstrated relation to cardiac outcomes, and variation in absolute T1 values between scanners, which makes inter-centre comparisons difficult. The relative merits of T1 at 3T versus T2* at 3T require further consideration
    • …
    corecore