410 research outputs found

    On the impact of controlled wall roughness shape on the flow of a soft-material

    Full text link
    We explore the impact of geometrical corrugations on the near-wall flow properties of a soft-material driven in a confined rough microchannel. By means of numerical simulations, we perform a quantitative analysis of the relation between the flow rate Φ\Phi and the wall stress σw\sigma_w for a number of setups, by changing both the roughness values as well as the roughness shape. Roughness suppresses the flow, with the existence of a characteristic value of σw\sigma_w at which flow sets in. Just above the onset of flow, we quantitatively analyze the relation between Φ\Phi and σw\sigma_w. While for smooth walls a linear dependency is observed, steeper behaviours are found to set in by increasing wall roughness. The variation of the steepness, in turn, depends on the shape of the wall roughness, wherein gentle steepness changes are promoted by a variable space localization of the roughness

    Time domain add-drop multiplexing scheme enhanced using a saw-tooth pulse shaper

    No full text
    We experimentally demonstrate the use of saw-tooth optical pulses, which are shaped using a fiber Bragg grating, to achieve robust and high performance time-domain add-drop multiplexing in a scheme based on cross-phase (XPM) modulation in an optical fiber, with subsequent offset filtering. As compared to the use of more conventional pulse shapes, such as Gaussian pulses of a similar pulse width, the purpose-shaped saw-tooth pulses allow higher extinction ratios for the add and drop windows and significant improvements in the receiver sensitivity for the dropped and added channels

    A sharp interface approach for wetting dynamics of coated droplets and soft particles

    Get PDF
    The wetting dynamics of liquid particles, from coated droplets to soft capsules, holds significant technological interest. Motivated by the need to simulate liquid metal droplets with an oxidized surface layer, in this work, we introduce a computational scheme that allows us to simulate droplet dynamics with general surface properties and model different levels of interface stiffness, also describing cases that are intermediate between pure droplets and capsules. Our approach is based on a combination of the immersed boundary and the lattice Boltzmann methods. Here, we validate our approach against the theoretical predictions in the context of shear flow and static wetting properties, and we show its effectiveness in accessing the wetting dynamics, exploring the ability of the scheme to address a broad phenomenology

    Laparoscopic removal of mullerian duct remnants in boys

    Get PDF
    Abstract: Purpose: Mullerian duct remnants (MDRs) are present in a male pseudohermaphroditic form characterized by failure of the mullerian duct to regress due to insufficient production or peripheral action of mullerian inhibiting substance. The MDR can be asymptomatic but it often results in infections, stones and voiding troubles. Furthermore, it may develop into a neoplasm. Therefore, surgery is mandatory for large MDRs and symptomatic patients. Laparoscopic removal is described. Materials and Methods: Six males were treated from February 1998 to February 2003. Age at surgery was between 3 and 18 years (mean 8.6). All patients showed severe hypospadias and 2 had mixed gonadal dysgenesis with ambiguous genitalia. Three patients presented with urogenital infections and all had a large MDR. Laparoscopic procedures, which were preceded by cystoscopy, were performed using a 10 mm umbilical trocar for the camera and 3, 5 mm trocars for instruments placed in the suprapubic region and iliac fossa bilaterally. The remnants were ligated with endoscopic loops or an endoscopic GIA stapler and cut. Results: Mean operative time was 2 hours. We noted no complications. In 2 cases there was deferential ectopia and in another of mixed gonadal dysgenesis bilateral gonadectomy was performed because of the risk of degeneration. Feeding started on postoperative day I and the patients were discharged home on day 5. After a followup of 8 months to 4 years all boys were healthy. Conclusions: Multiple approaches are used in traditional surgery, often leading to complications. Laparoscopy improves the view, decreases surgical risk and operative time, avoids large scars and allows more rapid hospital discharge

    Photonic chip based transmitter optimization and receiver demultiplexing of a 1.28 Tbit/s OTDM signal

    Get PDF
    We demonstrate chip-based Tbaud optical signal processing for all-optical performance monitoring, switching and demultiplexing based on the instantaneous Kerr nonlinearity in a dispersion-engineered As 2S 3 planar waveguide. At the Tbaud transmitter, we use a THz bandwidth radiofrequency spectrum analyzer to perform all-optical performance monitoring and to optimize the optical time division multiplexing stages as well as mitigate impairments, for example, dispersion. At the Tbaud receiver, we demonstrate error-free demultiplexing of a 1.28 Tbit/s single wavelength, return-to-zero signal to 10 Gbit/s via four-wave mixing with negligible system penalty (< 0.5 dB). Excellent performance, including high fourwave mixing conversion efficiency and no indication of an error-floor, was achieved. Our results establish the feasibility of Tbaud signal processing using compact nonlinear planar waveguides for Tbit/s Ethernet applications

    Adaptive Dispersion Compensation for Remote Fiber Delivery of NIR Femtosecond Pulses

    Full text link
    We report on remote delivery of 25 pJ broadband near-infrared femtosecond light pulses from a Ti:sapphire laser through 150 meters of single-mode optical fiber. Pulse distortion due to dispersion is overcome with pre-compensation using adaptive pulse shaping techniques, while nonlinearities are mitigated using an SF10 rod for the final stage of pulse compression. Near transform limited pulse duration of 130 fs is measured after the final compression.Comment: 3 pages, 4 figure

    Instantaneous frequency measurement system using optical mixing in highly nonlinear fiber

    Get PDF
    A broadband photonic instantaneous frequency measurement system utilizing four-wave mixing in highly nonlinear fiber is demonstrated. This new approach is highly stable and does not require any high-speed electronics or photodetectors. A first principles model accurately predicts the system response. Frequency measurement responses from 1 to 40 GHz are demonstrated and simple reconfiguration allows the system to operate over multiple bands

    EEG data analysis with stacked differentiable neural computers

    Full text link
    © 2018, Springer-Verlag London Ltd., part of Springer Nature. Differentiable neural computer (DNC) has demonstrated remarkable capabilities in solving complex problems. In this paper, we propose to stack an enhanced version of differentiable neural computer together to extend its learning capabilities. Firstly, we give an intuitive interpretation of DNC to explain the architectural essence and demonstrate the stacking feasibility by contrasting it with the conventional recurrent neural network. Secondly, the architecture of stacked DNCs is proposed and modified for electroencephalogram (EEG) data analysis. We substitute the original Long Short-Term Memory network controller by a recurrent convolutional network controller and adjust the memory accessing structures for processing EEG topographic data. Thirdly, the practicability of our proposed model is verified by an open-sourced EEG dataset with the highest average accuracy achieved; then after fine-tuning the parameters, we show the minimal mean error obtained on a proprietary EEG dataset. Finally, by analyzing the behavioral characteristics of the trained stacked DNCs model, we highlight the suitableness and potential of utilizing stacked DNCs in EEG signal processing

    Exploring the human chorionic gonadotropin induced steroid secretion profile of mouse Leydig tumor cell line 1 by a 20 steroid LC-MS/MS panel

    Get PDF
    The canonical androgen synthesis in Leydig cells involves Delta 5 and Delta 4 steroids. Besides, the backdoor pathway, eompassing 5 alpha and 5 alpha,3 alpha steroids, is gaining interest in fetal and adult pathophysiology. Moreover, the role of androgen epimers and progesterone metabolites is still unknown. We developed a liquid chromatographytandem mass spectrometry (LC-MS/MS) method for measuring 20 steroids and used it to investigate the steroid secretion induced by human chorionic gonadotropin (hCG) in the mouse Leydig tumor cell line 1 (mLTC1). Steroids were extracted from 500 mu L supernatants from unstimulated or 100 pM hCG-exposed mLTC1 cells, separated on a Luna C8 100 x 3 mm, 3 mu m column, with 100 mu M NH4F and methanol as mobile phases, and analyzed by positive electrospray ionization and multiple reaction monitoring. Sensitivity ranged within 0.012-38.0 nmol/L. Intra-assay and inter-assay imprecision were < 9.1% and 10.0%, respectively. Trueness, recovery and matrix factor were within 93.4-122.0, 55.6-104.1 and 76.4-106.3%, respectively. Levels of 16OH-progesterone, 11-deoxycortisol, androstenedione, 11-deoxycorticosterone, testosterone, 17OH-progesterone, androstenedione, epitestosterone, dihydrotestosterone, progesterone, androsterone and 17OH-allopregnanolone were effectively measured. Traces of 17OH-dihydroprogesterone, androstanediol and dihydroprogesterone were found, whereas androstenediol, 17OH-pregnenolone, dehydroepiandrosterone, pregnenolone and allopregnanolone showed no peak. hCG induced an increase of 80.2-102.5 folds in 16OH-progesterone, androstenedione and testosterone, 16.6 in dihydrotestosterone, 12.2-27.5 in epitestosterone, progesterone and metabolites, 8.1 in 17OH-allopregnanolone and <= 3.3 in 5 alpha and 5 alpha,3 alpha steroids
    corecore