10 research outputs found
Economic and sustainable development of the power sector of Mozambique
Includes bibliographical references.Mozambique has a vast potential of energy resources which are little exploited, particularly in the power sector. Mozambique’s diverse energy resource includes hydropower, natural gas, coal, biomass, solar and wind. Despite this, the country still faces constraints in increasing the level of access to energy. Therefore, the sustainable use of energy resources and the expansion and provision of reliable energy services for all districts is central to addressing many issues related with the development of the country. According to the Mozambican power utility, “Electricidade de Moçambique” (EDM), practically 97 of Mozambique’s electricity is generated from hydropower, with total installed capacity of 2179 Megawatts but due the existence of large reserves of coal and gas, the country is also intending to generate 1100 Megawatt from coal, 1790 Megawatt from gas and to increase the generation from hydro. However, before choosing those options regarding energy resources usage, it is important to assess the sustainability of the options from both socio-economic and environmental perspectives. Policies must wisely track reliable and affordable modern energy supplies and reduce the negative environmental impacts related to energy production and use and capital investments in equipment and energy infrastructure are crucial for developing the energy system. This study aims to examine socio-economic and environmental aspects of energy resource usage in Mozambique and the evaluation of Mozambique’s power supply alternatives into the future
Performance Enhancement of Proposed Namaacha Wind Farm by Minimising Losses Due to the Wake Effect: A Mozambican Case Study
District of Namaacha in Maputo Province of Mozambique presents a high wind potential, with an average wind speed of around 7.5 m/s and huge open fields that are favourable to the installation of wind farms. However, in order to make better use of the wind potential, it is necessary to evaluate the operating conditions of the turbines and guide the independent power producers (IPPs) on how to efficiently use wind power. The investigation of the wind farm operating conditions is justified by the fact that the implementation of wind power systems is quite expensive, and therefore, it is imperative to find alternatives to reduce power losses and improve energy production. Taking into account the power needs in Mozambique, this project applied hybrid optimisation of multiple energy resources (HOMER) to size the capacity of the wind farm and the number of turbines that guarantee an adequate supply of power. Moreover, considering the topographic conditions of the site and the operational parameters of the turbines, the system advisor model (SAM) was applied to evaluate the performance of the Vestas V82-1.65 horizontal axis turbines and the system’s power output as a result of the wake effect. For any wind farm, it is evident that wind turbines’ wake effects significantly reduce the performance of wind farms. The paper seeks to design and examine the proper layout for practical placements of wind generators. Firstly, a survey on the Namaacha’s electricity demand was carried out in order to obtain the district’s daily load profile required to size the wind farm’s capacity. Secondly, with the previous knowledge that the operation of wind farms is affected by wake losses, different wake effect models applied by SAM were examined and the Eddy–Viscosity model was selected to perform the analysis. Three distinct layouts result from SAM optimisation, and the best one is recommended for wind turbines installation for maximising wind to energy generation. Although it is understood that the wake effect occurs on any wind farm, it is observed that wake losses can be minimised through the proper design of the wind generators’ placement layout. Therefore, any wind farm project should, from its layout, examine the optimal wind farm arrangement, which will depend on the wind speed, wind direction, turbine hub height, and other topographical characteristics of the area. In that context, considering the topographic and climate features of Mozambique, the study brings novelty in the way wind farms should be placed in the district and wake losses minimised. The study is based on a real assumption that the project can be implemented in the district, and thus, considering the wind farm’s capacity, the district’s energy needs could be met. The optimal transversal and longitudinal distances between turbines recommended are 8Do and 10Do, respectively, arranged according to layout 1, with wake losses of about 1.7%, land utilisation of about 6.46 Km2, and power output estimated at 71.844 GWh per year
The role of microgrids on decoupling sharp fluctuations of electricity demand in centralized power system
Performance Enhancement of Proposed Namaacha Wind Farm by Minimising Losses Due to the Wake Effect: A Mozambican Case Study
District of Namaacha in Maputo Province of Mozambique presents a high wind potential, with an average wind speed of around 7.5 m/s and huge open fields that are favourable to the installation of wind farms. However, in order to make better use of the wind potential, it is necessary to evaluate the operating conditions of the turbines and guide the independent power producers (IPPs) on how to efficiently use wind power. The investigation of the wind farm operating conditions is justified by the fact that the implementation of wind power systems is quite expensive, and therefore, it is imperative to find alternatives to reduce power losses and improve energy production. Taking into account the power needs in Mozambique, this project applied hybrid optimisation of multiple energy resources (HOMER) to size the capacity of the wind farm and the number of turbines that guarantee an adequate supply of power. Moreover, considering the topographic conditions of the site and the operational parameters of the turbines, the system advisor model (SAM) was applied to evaluate the performance of the Vestas V82-1.65 horizontal axis turbines and the system’s power output as a result of the wake effect. For any wind farm, it is evident that wind turbines’ wake effects significantly reduce the performance of wind farms. The paper seeks to design and examine the proper layout for practical placements of wind generators. Firstly, a survey on the Namaacha’s electricity demand was carried out in order to obtain the district’s daily load profile required to size the wind farm’s capacity. Secondly, with the previous knowledge that the operation of wind farms is affected by wake losses, different wake effect models applied by SAM were examined and the Eddy–Viscosity model was selected to perform the analysis. Three distinct layouts result from SAM optimisation, and the best one is recommended for wind turbines installation for maximising wind to energy generation. Although it is understood that the wake effect occurs on any wind farm, it is observed that wake losses can be minimised through the proper design of the wind generators’ placement layout. Therefore, any wind farm project should, from its layout, examine the optimal wind farm arrangement, which will depend on the wind speed, wind direction, turbine hub height, and other topographical characteristics of the area. In that context, considering the topographic and climate features of Mozambique, the study brings novelty in the way wind farms should be placed in the district and wake losses minimised. The study is based on a real assumption that the project can be implemented in the district, and thus, considering the wind farm’s capacity, the district’s energy needs could be met. The optimal transversal and longitudinal distances between turbines recommended are 8Do and 10Do, respectively, arranged according to layout 1, with wake losses of about 1.7%, land utilisation of about 6.46 Km2, and power output estimated at 71.844 GWh per year.</jats:p
Improvement of Stand-Alone Solar PV Systems in the Maputo Region by Adapting Necessary Parameters
With the energy crisis and the constant blackout in the Mozambique Power Company grid, the option of applying solar photovoltaic (PV) systems has been one of the most used alternatives in the neighborhoods of the Maputo region. However, inefficient power delivery caused by unproper sizing and installation of stand-alone solar PV systems has been contributing to the low utilization of solar energy potential in the Maputo region. The optimal sizing and installation of the solar PV system is addressed to evaluate the influence of installation and operation parameters on the power output of PV modules. In this topic, PV modules parameters such as cell temperature, the module’s slope and azimuth angles, the losses caused by excessive heating of the module cells, shadows and dust on the PV module and the cooling process at the back of the module are assessed in order to find out the consequence of inadequate installation and operation parameters of solar PV systems in the Maputo region. The proper sizing and installation of the stand-alone solar PV system is fundamental to guarantee the continuous and efficient supply of power and, thus, different tools and techniques have been applied. This study will deal with the hybrid optimization of multiple energy resources (HOMER) and system advisor model (SAM), to size and improve power generation of solar PV systems. This study concluded that for the Maputo region, the optimal tilt angle is 23 ± 2° and the azimuth angle is 11 ± 2°. In addition, for optimization of the tilt and azimuth angles, it also examined the effect of module backside ventilation and proved that the system’s power generation increases with the rise of spacing between the module and the wall, since the strategy prevents the decline of the module cells efficiency. However, the maximum recommended spacing between the PV module and the mounting wall is about 0.4 m, since an effort to increase the spacing up to this level results in an insignificant growth of power output.</jats:p
Improvement of Stand-Alone Solar PV Systems in the Maputo Region by Adapting Necessary Parameters
With the energy crisis and the constant blackout in the Mozambique Power Company grid, the option of applying solar photovoltaic (PV) systems has been one of the most used alternatives in the neighborhoods of the Maputo region. However, inefficient power delivery caused by unproper sizing and installation of stand-alone solar PV systems has been contributing to the low utilization of solar energy potential in the Maputo region. The optimal sizing and installation of the solar PV system is addressed to evaluate the influence of installation and operation parameters on the power output of PV modules. In this topic, PV modules parameters such as cell temperature, the module’s slope and azimuth angles, the losses caused by excessive heating of the module cells, shadows and dust on the PV module and the cooling process at the back of the module are assessed in order to find out the consequence of inadequate installation and operation parameters of solar PV systems in the Maputo region. The proper sizing and installation of the stand-alone solar PV system is fundamental to guarantee the continuous and efficient supply of power and, thus, different tools and techniques have been applied. This study will deal with the hybrid optimization of multiple energy resources (HOMER) and system advisor model (SAM), to size and improve power generation of solar PV systems. This study concluded that for the Maputo region, the optimal tilt angle is 23 ± 2° and the azimuth angle is 11 ± 2°. In addition, for optimization of the tilt and azimuth angles, it also examined the effect of module backside ventilation and proved that the system’s power generation increases with the rise of spacing between the module and the wall, since the strategy prevents the decline of the module cells efficiency. However, the maximum recommended spacing between the PV module and the mounting wall is about 0.4 m, since an effort to increase the spacing up to this level results in an insignificant growth of power output
The rationale for implementing a premium economy class in the long haul markets – Evidence from the transatlantic market
The premium economy class is fast becoming an embedded and valued product that is being incorporated into the long haul fleets of the world's flag carriers. The premium economy unique proposition positions itself mid way between economy and business class with enhanced leg room as its primary attribute. It targets the price sensitive business traveller and the comfort seeking leisure passengers. This study contains an insight into the unit cost of production of economy, premium economy, business and first class seats and their potential to generate revenues on the lucrative London Heathrow to New York JFK route using a British Airways 747-400 aircraft. The main findings show that the rationale for implementing a premium economy seat is justified as it is only 1.6 times more expensive than an economy seat to produce, but it generates revenues that are 2.3 times higher than its cost of production - spawning the highest marginal returns from the four cabin hierarchy. The research reinforces the assumption that premium economy class cabins could very well become an embedded and sustainable product in the landscape of long haul travel in the near future