24 research outputs found

    Early intensive physical rehabilitation combined with a protocolized decannulation process in tracheostomized survivors from severe COVID-19 pneumonia with chronic critical illness

    Get PDF
    (1) Background: Intensive care unit (ICU) survivors from severe COVID-19 acute respiratory distress syndrome (CARDS) with chronic critical illness (CCI) may be considered vast resource consumers with a poor prognosis. We hypothesized that a holistic approach combining an early intensive rehabilitation with a protocol of difficult weaning would improve patient outcomes (2) Methods: A single-center retrospective study in a five-bed post-ICU weaning and intensive rehabilitation center with a dedicated fitness room specifically equipped to safely deliver physical activity sessions in frail patients with CCI. (3) Results: Among 502 CARDS patients admitted to the ICU from March 2020 to March 2022, 50 consecutive tracheostomized patients were included in the program. After a median of 39 ICU days, 25 days of rehabilitation were needed to restore patients’ autonomy (ADL, from 0 to 6; p < 0.001), to significantly improve their aerobic capacity (6-min walking test distance, from 0 to 253 m; p < 0.001) and to reduce patients’ vulnerability (frailty score, from 7 to 3; p < 0.001) and hospital anxiety and depression scale (HADS, from 18 to 10; p < 0.001). Forty-eight decannulated patients (96%) were discharged home. (4) Conclusions: A protocolized weaning strategy combined with early intensive rehabilitation in a dedicated specialized center boosted the physical and mental recovery

    Propriétés thermoélectriques des systèmes à deux couches minces superposées. Application à la mesure des flux thermiques

    No full text
    Les propriétés thermoélectriques des couches conductrices recouvertes d'un dépôt électrolytique de nature différente sont dues à des courants induits circulant à travers la surface séparant les conducteurs superposés. Ces courants sont proportionnels à la valeur locale du gradient thermique tangentiel. Les tensions électriques apparaissant dans le système sont représentatives des transferts thermiques et plus spécialement de la moyenne spatiale de la densité de flux de chaleur. Les résultats ont été utilisés pour concevoir le principe d'une nouvelle méthode de mesure des flux de chaleur

    Propriétés thermoélectriques des systèmes à deux couches minces superposées. Application à la mesure des flux thermiques

    No full text
    The thermoelectric properties of electrical conductors in the form of sheets and covered with an electrolytic deposit of different nature are due to the induced currents passing across the surface separating the conductors. These currents are proportional to the instant value of the calorific fluxes located in the electrolytic deposit. The electric voltages measured in the superposed conductors are representative of the heat transfers and most specially of the spatial average of the heat fluxes. The obtained results have been used to bring a new solution to the problem of measuring calorifical fluxes.Les propriétés thermoélectriques des couches conductrices recouvertes d'un dépôt électrolytique de nature différente sont dues à des courants induits circulant à travers la surface séparant les conducteurs superposés. Ces courants sont proportionnels à la valeur locale du gradient thermique tangentiel. Les tensions électriques apparaissant dans le système sont représentatives des transferts thermiques et plus spécialement de la moyenne spatiale de la densité de flux de chaleur. Les résultats ont été utilisés pour concevoir le principe d'une nouvelle méthode de mesure des flux de chaleur
    corecore