7,482 research outputs found

    A New Look at Azimuthal Wave Propagation Constants of an n-Layered Dielectric Coated PEC Cylinder

    Get PDF
    A method for determining the azimuthal wave propagation constants supported by an n-layered dielectric coated PEC cylinder is presented. The method, based on a Green\u27s function described in , is designed to optimally handle layered cylinders where the number of layers is extremely large as might be encountered in structures designed using transformational optics. The method is also tractable for any stratification profile without the need for individual layer analysis. We implement a recently developed numerical method to calculate Bessel functions of complex order and argument. Our method is verified by comparison with previously published results. We also present new results for a 5-layer case demonstrating self consistency and improved accuracy over published methods. Finally, to illustrate the method\u27s benefits, we present a brief analysis of two multilayer structures; a multilayer variation of the coated cylinder presented in and an example of a 7-layer case that approximates a material parameter gradient

    An Efficient Cost Function for the Optimization of an \u3cem\u3en\u3c/em\u3e-Layered Isotropic Cloaked Cylinder

    Get PDF
    In this paper, we present an efficient cost function for optimizing n-layered isotropic cloaked cylinders. Cost function efficiency is achieved by extracting the expression for the angle independent scatterer contribution of an associated Green\u27s function. Therefore, since this cost function is not a function of angle, accounting for every bistatic angle is not necessary and thus more efficient than other cost functions. With this general and efficient cost function, isotropic cloaked cylinders can be optimized for many layers and material parameters. To demonstrate this, optimized cloaked cylinders made of 10, 20 and 30 equal thickness layers are presented for TE and TM incidence. Furthermore, we study the effect layer thickness has on optimized cloaks by optimizing a 10 layer cloaked cylinder over the material parameters and individual layer thicknesses. The optimized material parameters in this effort do not exhibit the dual nature that is evident in the ideal transformation optics design. This indicates that the inevitable field penetration and subsequent PEC boundary condition at the cylinder must be taken into account for an optimal cloaked cylinder design. Furthermore, a more effective cloaked cylinder can be designed by optimizing both layer thickness and material parameters than by additional layers alone

    Functional Imaging of Autonomic Regulation: Methods and Key Findings.

    Get PDF
    Central nervous system processing of autonomic function involves a network of regions throughout the brain which can be visualized and measured with neuroimaging techniques, notably functional magnetic resonance imaging (fMRI). The development of fMRI procedures has both confirmed and extended earlier findings from animal models, and human stroke and lesion studies. Assessments with fMRI can elucidate interactions between different central sites in regulating normal autonomic patterning, and demonstrate how disturbed systems can interact to produce aberrant regulation during autonomic challenges. Understanding autonomic dysfunction in various illnesses reveals mechanisms that potentially lead to interventions in the impairments. The objectives here are to: (1) describe the fMRI neuroimaging methodology for assessment of autonomic neural control, (2) outline the widespread, lateralized distribution of function in autonomic sites in the normal brain which includes structures from the neocortex through the medulla and cerebellum, (3) illustrate the importance of the time course of neural changes when coordinating responses, and how those patterns are impacted in conditions of sleep-disordered breathing, and (4) highlight opportunities for future research studies with emerging methodologies. Methodological considerations specific to autonomic testing include timing of challenges relative to the underlying fMRI signal, spatial resolution sufficient to identify autonomic brainstem nuclei, blood pressure, and blood oxygenation influences on the fMRI signal, and the sustained timing, often measured in minutes of challenge periods and recovery. Key findings include the lateralized nature of autonomic organization, which is reminiscent of asymmetric motor, sensory, and language pathways. Testing brain function during autonomic challenges demonstrate closely-integrated timing of responses in connected brain areas during autonomic challenges, and the involvement with brain regions mediating postural and motoric actions, including respiration, and cardiac output. The study of pathological processes associated with autonomic disruption shows susceptibilities of different brain structures to altered timing of neural function, notably in sleep disordered breathing, such as obstructive sleep apnea and congenital central hypoventilation syndrome. The cerebellum, in particular, serves coordination roles for vestibular stimuli and blood pressure changes, and shows both injury and substantially altered timing of responses to pressor challenges in sleep-disordered breathing conditions. The insights into central autonomic processing provided by neuroimaging have assisted understanding of such regulation, and may lead to new treatment options for conditions with disrupted autonomic function

    Nanoindentation Technique for Characterizing Cantilever Beam Style RF Microelectromechanical Systems (MEMS) Switches

    Get PDF
    A nanoindentation technique was used to mechanically actuate a radio frequency micro-switch along with the measurement of contact resistance to investigate its applicability to characterize deflection and contact resistance behaviors of micro-sized cantilever beam switches. The resulting load–displacement relationship showed a discontinuity in slope when the micro-switch closed. The measured spring constants reasonably agreed with theoretical values obtained from the simple beam models. The change in contact resistance during test clearly indicated micro-switch closure but it did not coincide exactly with the physical contact between two electric contacts due to a resistive contaminated film

    Selecting Metal Alloy Electric Contact Materials for MEMS Switches

    Get PDF
    This paper presents a method for selecting metal alloys as the electric contact materials for microelectromechanical systems (MEMS) metal contact switches. This procedure consists of reviewing macro-switch lessons learned, utilizing equilibrium binary alloy phase diagrams, obtaining thin film material properties and, based on a suitable model, predicting contact resistance performance. After determining a candidate alloy material, MEMS switches were designed, fabricated and tested to validate the alloy selection methodology. Minimum average contact resistance values of 1.17 and 1.87 Ω were measured for micro-switches with gold (Au) and gold–platinum (Au–(6.3%)Pt) alloy electric contacts, respectively. In addition, \u27hot-switched\u27 life cycle test results of 1.02 × 108 and 2.70 × 108 cycles were collected for micro-switches with Au and Au–(6.3%)Pt contacts, respectively. These results indicate increased wear with a small increase in contact resistance for MEMS switches with metal alloy electric contacts

    Relationship between obstructive sleep apnea severity and sleep, depression and anxiety symptoms in newly-diagnosed patients.

    Get PDF
    Obstructive sleep apnea (OSA) occurs in at least 10% of the population, and leads to higher morbidity and mortality; however, relationships between OSA severity and sleep or psychological symptoms are unclear. Existing studies include samples with wide-ranging comorbidities, so we assessed relationships between severity of OSA and common sleep and psychological disturbances in recently diagnosed OSA patients with minimal co-morbidities. We studied 49 newly diagnosed, untreated OSA patients without major co-morbidities such as mental illness, cardiovascular disease, or stroke; subjects were not using psychoactive medications or tobacco (mean +/- std age: 46.8+/-9.1 years; apnea/hyponea index [AHI]: 32.1+/-20.5 events/hour; female/male: 12/37; weight <125 kg). We evaluated relationships between the AHI and daytime sleepiness (Epworth Sleepiness Scale; ESS), sleep quality (Pittsburg Sleep Quality Index; PSQI), depressive symptoms (Beck Depression Inventory-II; BDI), and anxiety symptoms (Beck Anxiety Inventory; BAI), as well as sex and body mass index (BMI). AHI was similar in females and males. Mean levels of all symptoms were above normal thresholds, but AHI was not correlated with age, ESS, PSQI, BDI, or BAI; only BMI was correlated with OSA severity. No differences in mean AHI appeared when subjects were grouped by normal versus elevated values of ESS, PSQI, BDI, or BAI. Consistent with other studies, a strong link between OSA severity and psychological symptoms did not appear in these newly diagnosed patients, suggesting that mechanisms additional to the number and frequency of hypoxic events and arousals occurring with apneas contribute to adverse health effects in OSA. OSA patients presenting with mild or moderate severity, and no major co-morbidities will not necessarily have low levels of sleep or psychological disturbances
    • …
    corecore