Ceiling-fan-integrated air conditioning: Airflow and temperature characteristics of a sidewall-supply jet interacting with a ceiling fan
Ceiling-Fan-Integrated Air Conditioning (CFIAC) is a proposed system that can greatly increase buildings’ cooling efficiency. In it, terminal supply ducts and diffusers are replaced by vents/nozzles, jetting supply air toward ceiling fans that serve to mix and distribute it within the room. Because of the fans’ air movement, the system provides comfort at higher room temperatures than in conventional commercial/ institutional/retail HVAC. We have experimentally evaluated CFIAC in a test room. This paper covers the distributions of air-speed, temperature, and calculated comfort level throughout the room. Two subsequent papers report tests of human subject comfort and ventilation effectiveness in the same experimental conditions. The room’s supply air emerged from a high-sidewall vent directed toward a ceiling fan on the jet centerline; we also tested this same jet on a fan located off to the side of the jet. Primary variables are: ceiling fan flow volumes in downward and upward directions, supply air volume, and room-vs-supply temperature difference. Velocity, turbulence, and temperature distributions are presented for vertical and horizontal transects of the room. The occupied zone is then evaluated for velocity and temperature non-uniformity, and for comfort as predicted by the ASHRAE Standard 55 elevated air speed method. We show that temperatures are well-mixed and uniform across the room for all of the fan-on configurations, for fans both within or out of the supply jet centerline. The ceiling fan flow dominates the CFIAC airflow, and even though non-uniform is capable of providing comfortable conditions throughout the occupied area of the room
Recommended from our members
Measuring 3D indoor air velocity via an inexpensive low-power ultrasonic anemometer
The ability to inexpensively monitor indoor air speed and direction on a continuous basis would transform the control of environmental quality and energy use in buildings. Air motion transports energy, ventilation air, and pollutants around building interiors and their occupants, and measured feedback about it could be used in numerous ways to improve building operation. However indoor air movement is rarely monitored because of the expense and fragility of sensors. This paper describes a unique anemometer developed by the authors, that measures 3-dimensional air velocity for indoor environmental applications, leveraging new microelectromechanical systems (MEMS) technology for ultrasonic range-finding. The anemometer uses a tetrahedral arrangement of four transceivers, the smallest number able to capture a 3-dimensional flow, that provides greater measurement redundancy than in existing anemometry. We describe the theory, hardware, and software of the anemometer, including algorithms that detect and eliminate shielding errors caused by the wakes from anemometer support struts. The anemometer has a resolution and starting threshold of 0.01 m/s, an absolute air speed error of 0.05 m/s at a given orientation with minimal filtering, 3.1° angle- and 0.11 m/s velocity errors over 360° azimuthal rotation, and 3.5° angle- and 0.07 m/s velocity errors over 135° vertical declination. It includes radio connection to internet and is able to operate standalone for multiple years on a standard battery. The anemometer also measures temperature and has a compass and tilt sensor so that flow direction is globally referenced regardless of anemometer orientation. The retail cost of parts is $100 USD, and all parts snap together for ease of assembly
Recommended from our members
Integrating Smart Ceiling Fans and Communicating Thermostats to Provide Energy-Efficient Comfort
The project goal was to identify and test the integration of smart ceiling fans and communicating thermostats. These highly efficient ceiling fans use as much power as an LED light bulb and have onboard temperature and occupancy sensors for automatic operationbased on space conditions. The Center for the Environment (CBE) at UC Berkeley led the research team including TRC, Association for Energy Affordability (AEA), and Big Ass Fans (BAF). The research team conducted laboratory tests, installed99 ceiling fans and 12 thermostats in four affordable multifamily housing sites in California’s Central Valley, interviewed stakeholders to develop a case study, developed an online design tool and design guide, outlined codes and standards outreach, and published several papers.The project team raised indoor cooling temperature setpoints and used ceiling fans as the first stage of cooling; this sequencing of ceiling fans and air conditioningreducesenergy consumption, especially during peak periods, while providing thermal comfort.The field demonstration resulted in 39% measured compressor energy savings during the April–October cooling seasoncompared to baseline conditions, normalized for floor area. Weather-normalized energy use varied from a 36% increase to 71% savings, withmedian savings of 15%.This variability reflects the diversity in buildings, mechanical systems, prior operation settings, space types, andoccupants’ schedules,preferences, and motivations. All commercial spaces with regular occupancy schedules (and twoof the irregularly-occupied commercial spaces and one of the homes) showed energy savings on an absolute basis before normalizing for warmer intervention temperatures,and 10 of 13 sites showed energy savings on a weather-normalized basis. The ceiling fans provided cooling for one site for months during hot weather when the coolingequipment failed.Occupants reported high satisfaction with the ceiling fans and improved thermal comfort. This technology can apply to new and retrofit residential and commercial buildings
Lessons Learned from Field Monitoring of Two Radiant Slab Office Buildings in California
AbstractIn this paper we present the results from field studies of two low-energy office buildings in California, both using radiant slab ceiling systems (thermally activated building systems, TABS) for primary cooling and heating in the buildings. Both buildings are certified LEED Platinum and incorporate a wide range of energy efficient technologies and design strategies, including TABS, advanced shading systems, underfloor air distribution, chilled beams, ceiling fans, natural ventilation, and photovoltaic panels. Findings and analysis from the following building performance assessment techniques will be discussed.•Occupant satisfaction survey. Occupant surveys are an invaluable source of information for describing how well the building is providing a high quality indoor environment for the occupants. In addition, the survey results are also compared against a large benchmark survey database of over 50,000 occupants.•Wireless measurement system. A network of wireless sensors was installed in selected zones of the buildings to provide additional more detailed information about the operation and control of the radiant slab system. This data was combined with trend data from the building management system (BMS) to examine the performance of the buildings during both winter and summer conditions. Some control issues were identified and corrected based on these measurements.•Energy performance analysis. We collected utility data for 2014 in one of the buildings and used this information to determine the building's Energy Star rating
Novel Xanthate Complexes for the Size Controlled Synthesis of Copper Sulfide Nanorods
We present a simple,
easily scalable route to monodisperse copper sulfide nanocrystals
by the hot injection of a series of novel copperÂ(I) xanthate single-source
precursors [(PPh<sub>3</sub>)<sub>2</sub>CuÂ(S<sub>2</sub>COR)] (R
= isobutyl, 2-methoxyethyl, 2-ethoxyethyl, 1-methoxy-2-propyl, 3-methoxy-1-butyl,
and 3-methoxy-3-methyl-1-butyl), whose crystal structures are also
reported. We show that the width of the obtained rods is dependent
on the length of the xanthate chain, which we rationalize through
a computational study, where we show that there is a relationship
between the ground-state energy of the precursor and the copper sulfide
rod width
Recommended from our members
Optimizing Radiant Systems for Energy Efficiency and Comfort
Radiant cooling and heating systems provide an opportunity to achieve significant energy savings, peak demand reduction, load shifting, and thermal comfort improvements compared to conventional all-air systems. As a result, application of these systems has increased in recent years, particularly in zero-net-energy (ZNE) and other advanced low-energy buildings. Despite this growth, completed installations to date have demonstrated that controls and operation of radiant systems can be challenging due to a lack of familiarity within the heating, ventilation, and air-conditioning (HVAC) design and operations professions, often involving new concepts (particularly related to the slow response in high thermal mass radiant systems). To achieve the significant reductions in building energy use proposed by California Public Utilities Commission’s (CPUC’s) Energy Efficiency Strategic Plan that all new non-residential buildings be ZNE by 2030, it is critical that new technologies that will play a major role in reaching this goal be applied in an effective manner. This final report describes the results of a comprehensive multi-faceted research project that was undertaken to address these needed enhancements to radiant technology by developing the following: (1) sizing and operation tools (currently unavailable on the market) to provide reliable methods to take full advantage of the radiant systems to provide improved energy performance while maintaining comfortable conditions, (2) energy, cost, and occupant comfort data to provide real world examples of energy efficient, affordable, and comfortable buildings using radiant systems, and (3) Title-24 and ASHRAE Standards advancements to enhance the building industry’s ability to achieve significant energy efficiency goals in California with radiant systems. The research team used a combination of full-scale fundamental laboratory experiments, whole-building energy simulations and simplified tool development, and detailed field studies and control demonstrations to assemble the new information, guidance and tools necessary to help the building industry achieve significant energy efficiency goals for radiant systems in California
- …