190 research outputs found

    Cetacean Habitat Selection in the Alaskan Arctic during Summer and Autumn

    Get PDF
    Ten years (1982-91) of sighting data from aerial surveys offshore of northern Alaska were analyzed to investigate seasonal variability in cetacean habitat selection. Distinct habitats were described for bowhead whales (Balaena mysticetus), white whales (Delphinapterus leucas), and gray whales (Eschrichtius robustus) on the basis of habitat selection ratios calculated for bathymetric and ice cover regimes. In summer, bowheads selected continental slope waters and moderate ice conditions; white whales selected slope and basin waters and moderate to heavy ice conditions; and gray whales selected coastal/shoal waters and open water. In autumn, bowheads selected inner shelf waters and light ice conditions; white whales selected outer shelf and slope waters and moderate to heavy ice; and gray whales selected coastal and shoal/trough habitats in light ice and open water. Habitat differences among species were significant in both seasons (ANOVA F > 28, p < 0.00001). Interseasonal depth and ice cover habitats were significantly different for bowhead whales (p < 0.00002), but not for gray whales (p > 0.35). White whale depth habitat was significantly different between seasons (p < 0.00002), but ice cover habitat was not (p < 0.08). Des données d'observation réalisées sur dix années (1982-1991) grâce à des relevés aériens au large de l'Alaska septentrional ont été analysées dans le cadre de recherches sur la variabilité saisonnière dans la sélection de l'habitat des cétacés. On a décrit des habitats distincts pour la baleine boréale (Balaena mysticetus), la baleine blanche (Delphinapterus leucas) et la baleine grise de Californie (Eschrichtius robustus) en se fondant sur les taux de sélection de l'habitat calculés pour le régime bathymétrique et celui de la couverture de glace. En été, la baleine boréale choisissait les eaux de la pente continentale et des conditions de glace modérée; la baleine blanche choisissait les eaux de la pente continentale et du bassin océanique, et des conditions de glace allant de modérée à épaisse; et la baleine grise choisissait des eaux côtières et de hauts-fonds ainsi que l'eau libre. En automne, la baleine boréale choisissait les eaux intérieures du plateau continental, où se trouvait une faible concentration de glace; la baleine blanche choisissait les eaux à l'extérieur du plateau et sur la pente, ainsi qu'une glace allant de modérée à épaisse; et la baleine grise choisissait des habitats côtiers et de hauts-fonds ou des fossés à faible concentration de glace et à eau libre. Les différences d'habitat entre les espèces étaient importantes durant les deux saisons (ANOVA F > 28, p < 0,00001). D'une saison à une autre, les habitats différaient sensiblement quant à la profondeur et à la couverture de glace pour la baleine boréale (p < 0,00002), mais pas pour la baleine grise (p > 0,35). La profondeur de l'habitat pour la baleine blanche variait sensiblement d'une saison à une autre (p <0,00002), mais pas la couverture de glace (p < 0,08).

    Adaptive windowing in contrast-enhanced intravascular ultrasound imaging

    Get PDF
    Intravascular ultrasound (IVUS) is one of the most commonly-used interventional imaging techniques and has seen recent innovations which attempt to characterize the risk posed by atherosclerotic plaques. One such development is the use of microbubble contrast agents to image vasa vasorum, fine vessels which supply oxygen and nutrients to the walls of coronary arteries and typically have diameters less than 200 µm. The degree of vasa vasorum neovascularization within plaques is positively correlated with plaque vulnerability. Having recently presented a prototype dual-frequency transducer for contrast agent-specific intravascular imaging, here we describe signal processing approaches based on minimum variance (MV) beamforming and the phase coherence factor (PCF) for improving the spatial resolution and contrast-to-tissue ratio (CTR) in IVUS imaging. These approaches are examined through simulations, phantom studies, ex vivo studies in porcine arteries, and in vivo studies in chicken embryos. In phantom studies, PCF processing improved CTR by a mean of 4.2 dB, while combined MV and PCF processing improved spatial resolution by 41.7%. Improvements of 2.2 dB in CTR and 37.2% in resolution were observed in vivo. Applying these processing strategies can enhance image quality in conventional B-mode IVUS or in contrast-enhanced IVUS, where signal-to-noise ratio is relatively low and resolution is at a premium

    Contrast Enhanced Superharmonic Imaging for Acoustic Angiography Using Reduced Form-Factor Lateral Mode Transmitters for Intravascular and Intracavity Applications

    Get PDF
    Techniques to image the microvasculature may play an important role in imaging tumor-related angiogenesis and vasa vasorum associated with vulnerable atherosclerotic plaques. However, the microvasculature associated with these pathologies is difficult to detect using traditional B-mode ultrasound or even harmonic imaging due to small vessel size and poor differentiation from surrounding tissue. Acoustic angiography, a microvascular imaging technique which utilizes superharmonic imaging (detection of higher order harmonics of microbubble response), can yield a much higher contrast to tissue ratio (CTR) than second harmonic imaging methods. In this work, two dual-frequency transducers using lateral mode transmitters were developed for superharmonic detection and acoustic angiography imaging in intracavity applications. A single element dual-frequency IVUS transducer was developed for concept validation, which achieved larger signal amplitude, better contrast to noise ratio (CNR) and pulse length compared to the previous work. A dual-frequency PMN-PT array transducer was then developed for superharmonic imaging with dynamic focusing. The axial and lateral size of the microbubbles in a 200 μm tube were measured to be 269 μm and 200 μm, respectively. The maximum CNR was calculated to be 22 dB. These results show that superharmonic imaging with a low frequency lateral mode transmitter is a feasible alternative to thickness mode transmitters when final transducer size requirements dictate design choices

    Management of Indeterminate Cystic Kidney Lesions: Review of Contrast-enhanced Ultrasound as a Diagnostic Tool

    Get PDF
    Indeterminate cystic kidney lesions found incidentally on abdominal imaging are an increasingly prevalent diagnostic challenge. The standard workup includes Bosniak classification with contrast-enhanced CT or MRI. However, these tests are costly and not without risks. Contrast-enhanced ultrasound (CEUS) is a relatively new imaging technique with lower risk of adverse events than iodine-containing contrast or gadolinium. In our review of the evidence for characterization of cystic kidney lesions with CEUS, CEUS displayed sensitivity (89–100%) and negative predictive value (86–100%) comparable to contrast-enhanced CT or MRI with no decrease in specificity compared to CT and only a slight decrease compared to MRI

    Molecular Acoustic Angiography: A New Technique for High-resolution Superharmonic Ultrasound Molecular Imaging

    Get PDF
    Ultrasound molecular imaging utilizes targeted microbubbles to bind to vascular targets such as integrins, selectins, and other extracellular binding domains. After binding, these microbubbles are typically imaged using low pressures and multi-pulse imaging sequences. In this article, we present an alternative approach for molecular imaging using ultrasound which relies on superharmonic signals produced by microbubble contrast agents. Bound bubbles were insonified near resonance using a low frequency (4 MHz) and superharmonic echoes were received at high frequencies (25–30 MHz). While this approach was observed to produce declining image intensity during repeated imaging in both in vitro and in vivo experiments due to bubble destruction, the feasibility of superharmonic molecular imaging was demonstrated for transmit pressures which are sufficiently high to induce shell disruption in bound microbubbles. This approach was validated using microbubbles targeted to the αvβ3 integrin in a rat fibrosarcoma model (n=5), and combined with superharmonic images of free microbubbles to produce high contrast, high resolution 3D volumes of both microvascular anatomy and molecular targeting. Image intensity over repeated scans and the effect of microbubble diameter were also assessed in vivo, indicating that larger microbubbles yield increased persistence in image intensity. Using ultrasound-based acoustic angiography images rather than conventional B-mode ultrasound to provide the underlying anatomical information facilitates anatomical localization of molecular markers. Quantitative analysis of relationships between microvasculature and targeting information indicated that most targeting occurred within 50 µm of a resolvable vessel (>100 µm diameter). The combined information provided by these scans may present new opportunities for analyzing relationships between microvascular anatomy and vascular targets, subject only to limitations of the current mechanically-scanned system and microbubble persistence to repeated imaging at moderate mechanical indices

    Early Assessment of Tumor Response to Radiation Therapy using High-Resolution Quantitative Microvascular Ultrasound Imaging

    Get PDF
    Measuring changes in tumor volume using anatomical imaging weeks to months post radiation therapy (RT) is currently the clinical standard for indicating treatment response to RT. For patients whose tumors do not respond successfully to treatment, this approach is suboptimal as timely modification of the treatment approach may lead to better clinical outcomes. We propose to use tumor microvasculature as a biomarker for early assessment of tumor response to RT. Acoustic angiography is a novel contrast ultrasound imaging technique that enables high-resolution microvascular imaging and has been shown to detect changes in microvascular structure due to cancer growth. Data suggest that acoustic angiography can detect longitudinal changes in the tumor microvascular environment that correlate with RT response

    Recruitment, growth and mortality of an Antarctic hexactinellid sponge, Anoxycalyx joubini.

    Get PDF
    Polar ecosystems are sensitive to climate forcing, and we often lack baselines to evaluate changes. Here we report a nearly 50-year study in which a sudden shift in the population dynamics of an ecologically important, structure-forming hexactinellid sponge, Anoxycalyx joubini was observed. This is the largest Antarctic sponge, with individuals growing over two meters tall. In order to investigate life history characteristics of Antarctic marine invertebrates, artificial substrata were deployed at a number of sites in the southern portion of the Ross Sea between 1967 and 1975. Over a 22-year period, no growth or settlement was recorded for A. joubini on these substrata; however, in 2004 and 2010, A. joubini was observed to have settled and grown to large sizes on some but not all artificial substrata. This single settlement and growth event correlates with a region-wide shift in phytoplankton productivity driven by the calving of a massive iceberg. We also report almost complete mortality of large sponges followed over 40 years. Given our warming global climate, similar system-wide changes are expected in the future

    Ex Vivo Porcine Arterial and Chorioallantoic Membrane Acoustic Angiography Using Dual-Frequency Intravascular Ultrasound Probes

    Get PDF
    The presence of blood vessels within a developing atherosclerotic plaque has been shown to be correlated to increased plaque vulnerability and ensuing cardiac events, however, detecting coronary intraplaque neovascularizations poses a significant challenge in the clinic. In this paper, we demonstrate in vivo a new intravascular ultrasound imaging method using a dual-frequency transducer to visualize contrast flow in microvessels with high specificity. This method uses a specialized transducer capable of exciting contrast agents at a low frequency (5.5 MHz) while detecting their nonlinear superhamonics at a much higher frequency (37 MHz). In vitro evaluation of the approach was performed in a microvascular phantom to produce 3D renderings of simulated vessel patterns and to determine image quality metrics as a function of depth. Furthermore, the ability of the system to detect microvessels is demonstrated both ex vivo using porcine arteries and in vivo using the chorioallantoic membrane of a developing chicken embryo with optical confirmation. Dual-frequency contrast specific imaging was able to resolve vessels of a similar size to those found in vulnerable atherosclerotic plaques at clinically relevant depths. The results of this study adds growing support for further evaluation and translation of contrast specific imaging in intravascular ultrasound for the detection of vulnerable plaques in atherosclerosis

    Marine Reserve Design: Optimal Size, Habitats, Species Affinities, Diversity, And Ocean Microclimate

    Get PDF
    The design of marine reserves is complex and fraught with uncertainty. However, protection of critical habitat is of paramount importance for reserve design. We present a case study as an example of a reserve design based on fine-scale habitats, the affinities of exploited species to these habitats, adult mobility, and the physical forcing affecting the dynamics of the habitats. These factors and their interaction are integrated in an algorithm that determines the optimal size and location of a marine reserve for a set of 20 exploited species within five different habitats inside a large kelp forest in southern California. The result is a reserve that encompasses similar to 42% of the kelp forest. Our approach differs fundamentally from many other marine reserve siting methods in which goals of area, diversity, or biomass are targeted a priori. Rather, our method was developed to determine how large a reserve must be within a specific area to protect a self-sustaining assemblage of exploited species. The algorithm is applicable across different ecosystems, spatial scales, and for any number of species. The result is a reserve in which habitat value is optimized for a predetermined set of exploited species against the area left open to exploitation. The importance of fine-scale habitat definitions for the exploited species off La Jolla is exemplified by the spatial pattern of habitats and the stability of these habitats within the kelp forest, both of which appear to be determined by ocean microclimate

    A preliminary engineering design of intravascular dual-frequency transducers for contrast-enhanced acoustic angiography and molecular imaging

    Get PDF
    Current intravascular ultrasound (IVUS) probes are not optimized for contrast detection because of their design for high-frequency fundamental-mode imaging. However, data from transcutaneous contrast imaging suggests the possibility of utilizing contrast ultrasound for molecular imaging or vasa vasorum assessment to further elucidate atherosclerotic plaque deposition. This paper presents the design, fabrication, and characterization of a small-aperture (0.6 × 3 mm) IVUS probe optimized for high-frequency contrast imaging. The design utilizes a dual-frequency (6.5 MHz/30 MHz) transducer arrangement for exciting microbubbles at low frequencies (near their resonance) and detecting their broadband harmonics at high frequencies, minimizing detected tissue backscatter. The prototype probe is able to generate nonlinear microbubble response with more than 1.2 MPa of rarefractional pressure (mechanical index: 0.48) at 6.5 MHz, and is also able to detect microbubble response with a broadband receiving element (center frequency: 30 MHz, −6-dB fractional bandwidth: 58.6%). Nonlinear super-harmonics from microbubbles flowing through a 200-μm-diameter micro-tube were clearly detected with a signal-to-noise ratio higher than 12 dB. Preliminary phantom imaging at the fundamental frequency (30 MHz) and dual-frequency super-harmonic imaging results suggest the promise of small aperture, dual-frequency IVUS transducers for contrast-enhanced IVUS imaging
    • …
    corecore