20,779 research outputs found

    Search for Lorentz Invariance and CPT Violation with the MINOS Far Detector

    Get PDF
    We searched for a sidereal modulation in the MINOS far detector neutrino rate. Such a signal would be a consequence of Lorentz and CPT violation as described by the standard-model extension framework. It also would be the first detection of a perturbative effect to conventional neutrino mass oscillations. We found no evidence for this sidereal signature, and the upper limits placed on the magnitudes of the Lorentz and CPT violating coefficients describing the theory are an improvement by factors of 20–510 over the current best limits found by using the MINOS near detector

    Improved Measurement of Muon Antineutrino Disappearance in MINOS

    Get PDF
    We report an improved measurement of ν̅_μ disappearance over a distance of 735 km using the MINOS detectors and the Fermilab Main Injector neutrino beam in a ν̅_μ-enhanced configuration. From a total exposure of 2.95×10^20 protons on target, of which 42% have not been previously analyzed, we make the most precise measurement of Δm̅^2=[2.62_(-0.28)^(+0.31)(stat)±0.09(syst)]×10^(-3)  eV^2 and constrain the ν_μ mixing angle sin^(2)(2θ̅)>0.75 (90% C.L.). These values are in agreement with Δm^2 and sin^(2)(2θ) measured for νμ, removing the tension reported in [ P. Adamson et al. Phys. Rev. Lett. 107 021801 (2011)]

    High Speed Photometry of SDSS J013701.06-091234.9

    Get PDF
    We present high speed photometry of the Sloan Digital Sky Survey cataclysmic variable SDSS J013701.06-091234.9 in quiescence and during its 2003 December superoutburst. The orbital modulation at 79.71\pm0.01 min is double humped; the superhump period is 81.702\pm0.007 min. Towards the end of the outburst late superhumps with a period of 81.29\pm0.01 min were observed. We argue that this is a system of very low mass transfer rate, and that it probably has a long outburst interval.Comment: 5 pages, 8 figures. Accepted for publication in MNRA

    Feedback in a cavity QED system for control of quantum beats

    Full text link
    Conditional measurements on the undriven mode of a two-mode cavity QED system prepare a coherent superposition of ground states which generate quantum beats. The continuous system drive induces decoherence through the phase interruptions from Rayleigh scattering, which manifests as a decrease of the beat amplitude and an increase of the frequency of oscillation. We report recent experiments that implement a simple feedback mechanism to protect the quantum beat. We continuously drive the system until a photon is detected, heralding the presence of a coherent superposition. We then turn off the drive and let the superposition evolve in the dark, protecting it against decoherence. At a later time we reinstate the drive to measure the amplitude, phase, and frequency of the beats. The amplitude can increase by more than fifty percent, while the frequency is unchanged by the feedback.Comment: 13 pages, 5 figures, ICAP 2012 23rd International Conference on Atomic Physic
    • …
    corecore