374 research outputs found

    Treatment with Methylphenidate for Attention Deficit Hyperactivity Disorder (ADHD) and the Risk of All-Cause Poisoning in Children and Adolescents:A Self-Controlled Case Series Study

    Get PDF
    BACKGROUND: Children and adolescents with attention deficit hyperactivity disorder (ADHD) are at higher risk of all-cause poisoning by drugs and chemicals (intentional or accidental). Currently, there is limited data on whether medication treatment for ADHD can reduce the risk of all-cause poisoning. METHODS: Patients aged 5–18 years with a methylphenidate (MPH) prescription and an incident poisoning diagnosis between January 2001 and June 2020 were identified from the Hong Kong Clinical Data Analysis and Reporting System. A self-controlled case series study design was used to compare the incidence rate ratios (IRRs) of all-cause poisoning during different risk windows (30 days before the first MPH prescription, exposure periods within 30 days of the first prescription, and periods of subsequent exposure) compared with the reference window (other non-exposure periods). RESULTS: 42,203 patients were prescribed ADHD medication in Hong Kong during the study period. Of these, 417 patients who had both an MPH prescription and poisoning incident recorded were included in the main analysis. Compared with other non-exposed periods, a higher risk of poisoning was found in the 30 days before the first prescription (IRR 2.64, 95% confidence interval [CI] 1.33–5.22) and exposure periods within 30 days of the first prescription (IRR 2.18, 95% CI 1.06–4.48), but not during prolonged exposure. However, compared with 30 days before the first prescription as well as exposure periods within 30 days of the first prescription, there was a lower risk during the subsequent exposure (IRRs 0.49 and 0.60, respectively). Similar results to the main analysis were also found in the subgroup analysis of intentional poisoning and females, but not in that of accidental poisoning and males. CONCLUSIONS: The risk of all-cause poisoning was higher shortly before and after the first MPH prescription and became lower during the subsequent prescription period. Our results do not support an association between the use of MPH and an increased risk of all-cause poisoning in children and adolescents and, in fact, suggest that longer-term use of MPH may be associated with a lower risk of all-cause poisoning, although this latter finding requires further study. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s40263-021-00824-x

    Prenatal antidepressant use and risk of attention-deficit/hyperactivity disorder in offspring:population based cohort study

    Get PDF
    textabstractObjective To assess the potential association between prenatal use of antidepressants and the risk of attention-deficit/hyperactivity disorder (ADHD) in offspring. Design Population based cohort study. Setting Data from the Hong Kong population based electronic medical records on the Clinical Data Analysis and Reporting System. Participants 190 618 children born in Hong Kong public hospitals between January 2001 and December 2009 and followed-up to December 2015. Main outcome measure Hazard ratio of maternal antidepressant use during pregnancy and ADHD in children aged 6 to 14 years, with an average follow-up time of 9.3 years (range 7.4-11.0 years). Results Among 190 618 children, 1252 had a mother who used prenatal antidepressants. 5659 children (3.0%) were given a diagnosis of ADHD or received treatment for ADHD. The crude hazard ratio of maternal antidepressant use during pregnancy was 2.26 (P<0.01) compared with non-use. After adjustment for potential confounding factors, including maternal psychiatric disorders and use of other psychiatric drugs, the adjusted hazard ratio was reduced to 1.39 (95% confidence interval 1.07 to 1.82, P=0.01). Likewise, similar results were observed when comparing children of mothers who had used antidepressants before pregnancy with those who were never users (1.76, 1.36 to 2.30, P<0.01). The risk of ADHD in the children of mothers with psychiatric disorders was higher compared with the children of mothers without psychiatric disorders even if the mothers had never used antidepressants (1.84, 1.54 to 2.18, P<0.01). All sensitivity analyses yielded similar results. Sibling matched analysis identified no significant difference in risk of ADHD in siblings exposed to antidepressants during gestation and those not exposed during gestation (0.54, 0.17 to 1.74, P=0.30). Conclusions The findings suggest that the association between prenatal use of antidepressants and risk of ADHD in offspring can be partially explained by confounding by indication of antidepressants. If there is a causal association, the size of the effect is probably smaller than that reported previously

    Organization of Block Copolymers using NanoImprint Lithography: Comparison of Theory and Experiments

    Full text link
    We present NanoImprint lithography experiments and modeling of thin films of block copolymers (BCP). The NanoImprint lithography is used to align perpendicularly lamellar phases, over distances much larger than the natural lamellar periodicity. The modeling relies on self-consistent field calculations done in two- and three-dimensions. We get a good agreement with the NanoImprint lithography setups. We find that, at thermodynamical equilibrium, the ordered BCP lamellae are much better aligned than when the films are deposited on uniform planar surfaces

    Comparison of eligible non-enrolled patients and the randomised TWENTE trial population treated with Resolute and XIENCE V drug-eluting stents

    Get PDF
    Aims: The TWENTE trial recently enrolled more than 80% of all eligible patients, who were randomised to zotarolimus-eluting Resolute or everolimus-eluting XIENCE V stents. In the present study, we investigated whether eligible, non-enrolled patients differed from the randomised TWENTE trial population in baseline characteristics and one-year outcome. Methods and results: Characteristics of 1,709 eligible patients were analysed. Independent external adjudication of clinical events was likewise performed for non-enrolled (n=318) and randomised patients (n=1,391). Non-enrolled and randomised patients did not differ in gender distribution, diabetes mellitus, and clinical presentation, but differed significantly in age and cardiovascular history. Nevertheless, clinical outcome after one year did not differ in the primary composite endpoint target-vessel failure (TVF; 9.8% vs. 8.1%; p=0.34), and its components cardiac death (1.6% vs. 1.2%; p=0.61), target vessel-related myocardial infarction (4.7% vs. 4.6%; p=0.92), and target-vessel revascularisation (3.8% vs. 3.0%; p=0.48). Previous bypass surgery predicted TVF in non-enrolled patients (p=0.001); removal of these patients resulted in identical TVF rates for non-enrolled and randomised patients (7.3% vs. 7.3%; p=0.99). Conclusions: Despite some differences in baseline characteristics, non-enrolled and randomised patients did not differ in one-year outcome, which was favourable for both populations and may be related to the drug-eluting stents used

    A Randomized Controlled Trial in Second-Generation Zotarolimus-Eluting Resolute Stents Versus Everolimus-Eluting Xience V Stents in Real-World Patients : The TWENTE Trial

    Get PDF
    ObjectivesThe aim of this study was to compare the safety and efficacy of Resolute zotarolimus-eluting stents (ZES) (Medtronic Cardiovascular, Santa Rosa, California) with Xience V everolimus-eluting stents (EES) (Abbott Vascular Devices, Santa Clara, California) at 1-year follow-up.BackgroundOnly 1 randomized trial previously compared these stents.MethodsThis investigator-initiated, patient-blinded, randomized noninferiority study had limited exclusion criteria (acute ST-segment elevation myocardial infarctions not eligible). Patients (n = 1,391; 81.4% of eligible population) were randomly assigned to ZES (n = 697) or EES (n = 694). Liberal use of stent post-dilation was encouraged. Cardiac biomarkers were systematically assessed. The primary endpoint was target vessel failure (TVF), a composite of cardiac death, myocardial infarction not clearly attributable to non-target vessels, and clinically indicated target-vessel revascularization. An external independent research organization performed clinical event adjudication (100% follow-up data available). Analysis was by intention-to-treat.ResultsAcute coronary syndromes were present in 52% and “off-label” feature in 77% of patients. Of the lesions, 70% were type B2/C; the post-dilation rate was very high (82%). In ZES and EES, TVF occurred in 8.2% and 8.1%, respectively (absolute risk-difference 0.1%; 95% confidence interval: −2.8% to 3.0%, pnoninferiority = 0.001). There was no significant between-group difference in TVF components. The definite-or-probable stent thrombosis rates were relatively low and similar for ZES and EES (0.9% and 1.2%, respectively, p = 0.59). Definite stent thrombosis rates were also low (0.58% and 0%, respectively, p = 0.12). In EES, probable stent thrombosis beyond day 8 was observed only in patients not adhering to dual antiplatelet therapy.ConclusionsResolute ZES were noninferior to Xience V EES in treating “real-world” patients with a vast majority of complex lesions and “off-label” indications for drug-eluting stents, which were implanted with liberal use of post-dilation. (The Real-World Endeavor Resolute Versus XIENCE V Drug-Eluting SteNt Study: Head-to-head Comparison of Clinical Outcome After Implantation of Second Generation Drug-eluting Stents in a Real World Scenario; NCT01066650

    Clinical Outcome Following Stringent Discontinuation of Dual Antiplatelet Therapy After 12 Months in Real-World Patients Treated With Second-Generation Zotarolimus-Eluting Resolute and Everolimus-Eluting Xience V Stents : 2-Year Follow-Up of the Randomized TWENTE Trial

    Get PDF
    Objectives The aim of this study was to assess the safety and efficacy of the implantation of Resolute zotarolimus-eluting stents (ZES) (Medtronic Inc., Santa Rosa, California) and Xience V everolimus-eluting stents (EES) (Abbott Vascular, Santa Clara, California) following strict discontinuation of dual antiplatelet therapy (DAPT) after 12 months. Background Only limited long-term follow-up data are available from head-to-head comparisons of second-generation drug-eluting stents. Methods The randomized TWENTE (The Real-World Endeavor Resolute Versus Xience V Drug-Eluting Stent Study in Twente) trial is an investigator-initiated study performed in a population with many complex patients and lesions and only limited exclusion criteria. Patients were randomly assigned 1:1 to ZES (n = 697) or EES (n = 694). Results Two-year follow-up information was available on all patients. The rate of continuation of DAPT beyond 12 months was very low (5.4%). The primary endpoint of target vessel failure, a composite of cardiac death, target vessel–related myocardial infarction, and target vessel revascularization, did not differ between ZES and EES (10.8% vs. 11.6, p = 0.65), despite fewer target lesion revascularizations in patients with EES (2.6% vs. 4.9%, p = 0.03). The patient-oriented composite endpoint was similar (16.4% vs. 17.1%, p = 0.75). Two-year rates of definite or probable stent thrombosis were 1.2% and 1.4%, respectively (p = 0.63). Very late definite or probable stent thrombosis occurred only in 2 patients in each study arm (0.3% vs. 0.3%, p = 1.00). Conclusions After 2 years of follow-up and stringent discontinuation of DAPT beyond 12 months, Resolute ZES and Xience V EES showed similar results in terms of safety and efficacy for treating patients with a majority of complex lesions and off-label indications for drug-eluting stents. (The Real-World Endeavor Resolute Versus Xience V Drug-Eluting Stent Study in Twent

    TCT-47 Two-Year Clinical Outcome of the TWENTE Trial, a Randomized Controlled Trial Comparing Second-Generation Zotarolimus-Eluting Resolute Stents Versus Everolimus-Eluting Xience V Stents in Real-World Patients

    Get PDF
    Background: In the prospective, randomized TWENTE trial, the zotarolimus-eluting Resolute stent was at 1 year follow-up non-inferior to the everolimus-eluting Xience V stent for the primary endpoint target vessel failure. This composite endpoint consisted of cardiac death, clinically indicated target vessel revascularization, or target vessel-related myocardial infarction (MI). So far, few long-term data of prospective head-to-head comparisons between both DES have been reported. Methods: Patients requiring percutaneous coronary interventions (PCI) with DES implantation at Thoraxcentrum Twente in Enschede were randomization between Resolute (Medtronic Vascular, Santa Rosa, CA, USA) and Xience V (Abbott Vascular, Santa Clara, CA, USA) in a 1:1 fashion. Inclusion of all coronary or bypass graft lesions and all clinical settings was permitted except for primary PCI (i.e. acute ST-elevation myocardial infarction (STEMI) was an exclusion criterion). Both external monitoring and clinical event adjudication were performed by an independent external contract research organization (Cardialysis, Rotterdam, the Netherlands). Two year clinical follow-up was performed as indicated in the study protocol. Results: A total of 1,391 patients were enrolled in the TWENTE trial between June 2008 and August 2010. The study population comprised 21.6% diabetics with a vast majority of complex lesions and “off-label” indications for drug-eluting stents (77.4%). Patients presented with either stable angina (48.5%) or unstable angina/Non-STEMI (51.5%). Demographics, baseline angiographic and procedural data, and 2-year clinical follow-up data will be presented. This includes the primary endpoint of the study: Target vessel failure (TVF) at 2 year follow-up. Secondary endpoints include the individual components of the primary endpoint and the incidence of very late stent thrombosis. In addition, results of subgroup analyses will be reported. Conclusions: Results of pre-specified analyses of 2-year clinical outcome of the TWENTE trial will be presented at TCT 2012

    Homozygous deletion in MICU1 presenting with fatigue and lethargy in childhood.

    Get PDF
    OBJECTIVE: To define the mechanism responsible for fatigue, lethargy, and weakness in 2 cousins who had a normal muscle biopsy. METHODS: Exome sequencing, long-range PCR, and Sanger sequencing to identify the pathogenic mutation. Functional analysis in the patient fibroblasts included oxygen consumption measurements, extracellular acidification studies, Western blotting, and calcium imaging, followed by overexpression of the wild-type protein. RESULTS: Analysis of the exome sequencing depth revealed a homozygous deletion of exon 1 of MICU1 within a 2,755-base pair deletion. No MICU1 protein was detected in patient fibroblasts, which had impaired mitochondrial calcium uptake that was rescued through the overexpression of the wild-type allele. CONCLUSIONS: MICU1 mutations cause fatigue and lethargy in patients with normal mitochondrial enzyme activities in muscle. The fluctuating clinical course is likely mediated through the mitochondrial calcium uniporter, which is regulated by MICU1.Wellcome Trust (101876/Z/13/Z, 096919Z/11/Z), Medical Research Council (UK) (G0601943), Medical Research Council Mitochondrial Biology Unit (MC_UP_1501/2).This is the final version of the article. It first appeared from Wolters Kluwer via https://doi.org/10.1212/NXG.000000000000005

    The effect of portable HEPA filter air cleaners on indoor PM2.5 concentrations and second hand tobacco smoke exposure among pregnant women in Ulaanbaatar, Mongolia: The UGAAR randomized controlled trial

    Get PDF
    Background Portable HEPA filter air cleaners can reduce indoor fine particulate matter (PM2.5), but their use has not been adequately evaluated in high pollution settings. We assessed air cleaner effectiveness in reducing indoor residential PM2.5 and second hand smoke (SHS) exposures among non-smoking pregnant women in Ulaanbaatar, Mongolia. Methods We randomized 540 participants to an intervention group receiving 1 or 2 HEPA filter air cleaners or a control group receiving no air cleaners. We followed 259 intervention and 253 control participants to the end of pregnancy. We measured one-week indoor residential PM2.5 concentrations in early (~11weeks gestation) and late (~31weeks gestation) pregnancy and collected outdoor PM2.5 data from centrally-located government monitors. We assessed blood cadmium in late pregnancy. Hair nicotine was quantified in a subset (n=125) to evaluate blood cadmium as a biomarker of SHS exposure. We evaluated air cleaner effectiveness using mixed effects and multiple linear regression models and used stratified models and interaction terms to evaluate potential modifiers of effectiveness. Results The overall geometric mean (GM) one-week outdoor PM2.5 concentration was 47.9?g/m3 (95% CI: 44.6, 51.6?g/m3), with highest concentrations in winter (118.0?g/m3; 110.4, 126.2?g/m3). One-week indoor and outdoor PM2.5 concentrations were correlated (r=0.69). Indoor PM2.5 concentrations were 29% (21, 37%) lower in intervention versus control apartments, with GMs of 17.3?g/m3 (15.8, 18.8?g/m3) and 24.5?g/m3 (22.2, 27.0?g/m3), respectively. Air cleaner effectiveness was greater when air cleaners were first deployed (40%; 31, 48%) than after approximately five months of use (15%; 0, 27%). Blood cadmium concentrations were 14% (4, 23%) lower among intervention participants, likely due to reduced SHS exposure. Conclusions Portable HEPA filter air cleaners can lower indoor PM2.5 concentrations and SHS exposures in highly polluted settings.Canadian Institute of Health Research (MOP 142380)Simon Fraser University, Faculty of Health Sciences (Mowafaghian Child Health Faculty Award
    • 

    corecore