71 research outputs found

    Multiplex Bead Array Assay for Detection of 25 Soluble Cytokines in Blister Fluid of Patients with Complex Regional Pain Syndrome Type 1

    Get PDF
    Inflammatory processes are known to be involved at least in the early phase of complex regional pain syndrome type 1 (CRPS1). Blister fluid obtained from the involved extremities displayed increased amounts of proinflammatory cytokines IL-6 and TNFα compared with the noninvolved extremities. The aim of this paper is to investigate the involvement of mediators by measurement of several other cytokines using new detection techniques that enable multiple cytokine measurement in small samples. The use of a multiplex-25 bead array cytokine assay and Luminex technology enabled simultaneous measurement of representative (1) proinflammatory cytokines such as GM-CSF, IL-1β, IL-1RA, IL-6, IL-8, and TNF-α; (2) Th1/Th2 distinguishing cytokines IFN-γ, IL-2, IL-2R, IL-4, IL-5, and IL-10; (3) nonspecific acting cytokines IFN-α, IL-7, IL-12p40/p70, IL-13, IL-15, and IL-17; and (4) chemokines eotaxin, IP-10, MCP-1, MIP-1α, MIP-1β, MIG, and RANTES. Although minimal detection levels are significantly higher in the bead array system than those in common ELISA assays, in blister fluid, IL-1RA, IL-6, IL-8, TNF-α, IL-12p40/p70, MCP-1, and MIP-1β were detectable and increased in CRPS1 affected extremities. Levels of IL-6 and TNF-α simultaneously measured by ELISA (Sanquin Compact kit) and by multiplex-25 bead array assay (Biosource) were highly correlated (r = 0.85, P < .001 for IL-6 and r = 0.88, P < .001 for TNF-α). Furthermore, IP-10 and eotaxin were detectable but diminished in CRPS1, whereas detectable amounts of IL-10 were similar in involved and noninvolved extremities. Multiplex bead array assays are useful systems to establish the involvement of cytokines in inflammatory processes by measurements in blister fluids of CRPS1. Ten representative cytokines were detectable. However, detection levels and amounts measured are at least 3 times higher in the multiplex-25 array assay than in the ELISA assays used simultaneously for the measurement of cytokines

    Genotype–Phenotype Correlation in DFNB8/10 Families with TMPRSS3 Mutations

    Get PDF
    In the present study, genotype–phenotype correlations in eight Dutch DFNB8/10 families with compound heterozygous mutations in TMPRSS3 were addressed. We compared the phenotypes of the families by focusing on the mutation data. The compound heterozygous variants in the TMPRSS3 gene in the present families included one novel variant, p.Val199Met, and four previously described pathogenic variants, p.Ala306Thr, p.Thr70fs, p.Ala138Glu, and p.Cys107Xfs. In addition, the p.Ala426Thr variant, which had previously been reported as a possible polymorphism, was found in one family. All affected family members reported progressive bilateral hearing impairment, with variable onset ages and progression rates. In general, the hearing impairment affected the high frequencies first, and sooner or later, depending on the mutation, the low frequencies started to deteriorate, which eventually resulted in a flat audiogram configuration. The ski-slope audiogram configuration is suggestive for the involvement of TMPRSS3. Our data suggest that not only the protein truncating mutation p.T70fs has a severe effect but also the amino acid substitutions p.Ala306Thr and p.Val199Met. A combination of two of these three mutations causes prelingual profound hearing impairment. However, in combination with the p.Ala426Thr or p.Ala138Glu mutations, a milder phenotype with postlingual onset of the hearing impairment is seen. Therefore, the latter mutations are likely to be less detrimental for protein function. Further studies are needed to distinguish possible phenotypic differences between different TMPRSS3 mutations. Evaluation of performance of patients with a cochlear implant indicated that this is a good treatment option for patients with TMPRSS3 mutations as satisfactory speech reception was reached after implantation

    Occupational Noise, Smoking, and a High Body Mass Index are Risk Factors for Age-related Hearing Impairment and Moderate Alcohol Consumption is Protective: A European Population-based Multicenter Study

    Get PDF
    A multicenter study was set up to elucidate the environmental and medical risk factors contributing to age-related hearing impairment (ARHI). Nine subsamples, collected by nine audiological centers across Europe, added up to a total of 4,083 subjects between 53 and 67 years. Audiometric data (pure-tone average [PTA]) were collected and the participants filled out a questionnaire on environmental risk factors and medical history. People with a history of disease that could affect hearing were excluded. PTAs were adjusted for age and sex and tested for association with exposure to risk factors. Noise exposure was associated with a significant loss of hearing at high sound frequencies (>1 kHz). Smoking significantly increased high-frequency hearing loss, and the effect was dose-dependent. The effect of smoking remained significant when accounting for cardiovascular disease events. Taller people had better hearing on average with a more pronounced effect at low sound frequencies (<2 kHz). A high body mass index (BMI) correlated with hearing loss across the frequency range tested. Moderate alcohol consumption was inversely correlated with hearing loss. Significant associations were found in the high as well as in the low frequencies. The results suggest that a healthy lifestyle can protect against age-related hearing impairment

    Optokinetic response in patients with vestibular areflexia

    No full text
    Abstract. Optokinetic nystagmus (OKN) responses (stimuli 40 • /s and 60 • /s) were evaluated in 121 patients with vestibular areflexia (VA) and were compared with a control group of 99 control subjects matched by age. The mean response levels were significantly higher in the VA group than in the control group: 1.7 • /s at 40 • /s stimulation, and 4.4 • /s at 60 • /s. The VA group showed a significantly wider scattering and greater variances and, as a group, they exhibited higher OKN gains than the control subjects. We suggest that the higher gain of OKN responses in VA patients can be attributed to an increased efficiency in signal processing by the cortical optokinetic system. This enhancement may be similar to the enhancement which, in healthy subjects, is produced by &quot;optokinetic training&quot;
    • …
    corecore