8 research outputs found

    Utilização do adesivo N-butil cianoacrilato e o do fio poliglactina na rafia de córnea em coelhos (Oryctolagus cunicullus)

    Get PDF
    The aim of this study was to evaluate the cicatricial repair of perforated cornea in rabbits, by using the N-butyl cyanoacrylate adhesive compared to the 910-polyglactine nº 7-0 thread suture through macroscopic and histological assays. Corneas from 18 adult rabbits were perforated and soon after submitted the synthesis with N-butyl cyanoacrylate synthetic adhesive right ocular globe or by simple interrupted sutures using the 910-polyglactine thread left ocular globe. The animals were separate in three groups of the same number. Examination after 7, 15, and 30 days post-operative showed that both the synthetic adhesive and the suture were efficient in the synthesis of the surgical wounds, thus stabilizing the intra-ocular contents. The N-butyl cyanoacrylate adhesive was showed to be superior to the 910-polyglactine suture thread with regards to the evolution and the organization of the healing process.Objetivou-se avaliar, por meio de estudos macroscópicos e histológicos, a reparação cicatricial da córnea de coelhos perfuradas, ocluidas com o adesivo N-butil cianoacrilato, comparado à sutura com fio poliglactina 910 nº 7-0. As córneas de 18 coelhos adultos foram perfuradas e em seguidas submetidas a ráfia, sendo a ferida da córnea do globo ocular direito com o adesivo sintético N-butil cianoacrilato e a do globo ocular esquerdo com pontos simples separados com fio poliglactina 910. Os animais foram separados em três grupos de igual número e decorridos 7, 15 e 30 dias de pós operatório notou-se que tanto o adesivo sintético como a sutura foram eficientes na síntese das feridas, estabilizando o conteúdo intra-ocular. O adesivo N-butil cianoacrilato mostrou-se superior ao fio de sutura poliglactina 910 quanto à evolução e organização do processo cicatricial

    Eletroacupuntura aplicada nas fases precoce e tardia da cicatrização do tendão calcanear comum de coelhos após reparo tardio com peritônio bovino conservado em solução supersaturada de sal: aspectos clínicos

    No full text
    Para avaliar o uso da eletroacupuntura (EA) sobre os aspectos clínicos e deambulatórios, 36 coelhos tiveram o tendão calcanear comum seccionado e, após 30 dias, receberam enxerto de peritônio bovino conservado em solução supersaturada de sal. em seguida, os animais foram distribuídos aleatoriamente em três grupos de igual número: no primeiro grupo, os coelhos foram estimulados pela EA do segundo ao 11° dia de pós-operatório (PO) (E10); no segundo grupo do 11o ao 31o dia de PO (E20) e, no terceiro grupo, os animais não foram estimulados (C). Verificou-se, nos animais do E10, durante o PO, ausência de edema e hiperemia no membro tratado pela EA. Não se observou diferença significativa (P>0,05) entre os grupos quanto ao grau de deambulação dos animais. Todos os coelhos tiveram completa recuperação da deambulação até os 51 dias de PO. A utilização da eletroacupuntura na fase precoce da cicatrização do tendão calcanear comum de coelhos impediu a formação de edema e hiperemia. O tratamento com eletroacupuntura no PO não melhorou o desempenho da deambulação.In order to evaluate the use of eletroacupuncture (EA) on clinical and functional aspects, the Acchiles tendon of thirty-two rabbits was sectioned and after 30 days was grafted using salt supersatured - stored bovine peritoneum graft. Then, animals were distributed into three equally groups. They were stimulated by EA from the second to 11th post - operative day (S10 group), from 11th to 31th pos-operative day (S20 group), or were not stimulated (C group). Neither edema nor hyperemia were detected on S10 animals. There were no significant (P>0.05) differences between groups related to functional aspects. All rabbits were recovered until the 51th day of the post-operative period. The use of eletroacupuncture on acute Acchiles tendon healing avoided edema and hyperemia, but did not improve functional aspects

    Eletroacupuntura e morfina sobre parâmetros cardiorrespiratórios em gatas submetidas à ovariosalpingohisterectomia eletiva Electroacupuncture and morphine on cardiorespiratory parameters on cat elective ovariohysterectomy

    No full text
    Objetivou-se avaliar os efeitos da morfina e da eletroacupuntura sobre parâmetros cardiorrespiratórios e consumo do anestésico isofluorano em gatas submetidas à ovariosalpingohisterectomia eletiva. Foram utilizadas 18 gatas hígidas, adultas, distribuídas em três grupos: Eletroacupuntura, Morfina e Controle, as quais receberam acepromazina, propofol e isoflurano. Nos animais dos grupos Controle e Morfina foram introduzidas agulhas em acupontos falsos, e nos do grupo Eletroacupuntura nos pontos Zusanli e Yanglingquan. A eletroestimulação no grupo submetido a Eletroacupuntura foi realizada na frequência de 2 e 100Hz. Nos animais do grupo Morfina, administrou-se a dose de 0,3mg/kg por via intramuscular e no grupo Controle não foi realizado tratamento. O registro das variáveis foi obtido anteriormente à administração da acepromazina; 10 minutos após a aplicação desse fármaco; após indução e estabilização anestésica; decorridos 30 minutos do início da eletroestimulação ou aplicação da morfina; e a cada 10 minutos, durante 60 minutos. Foram estudadas temperatura retal, frequência respiratória e cardíaca, saturação parcial de oxiemoglobina, pressão arterial média, volume total de isoflurano consumido e volume inspirado de isoflurano. Os dados foram submetidos a Análise de Perfil. Somente os animais do grupo Eletroacupuntura (GE) não apresentaram diferença significativa entre os momentos para a pressão arterial média, e observou-se melhor estabilidade cardíaca nos animais do grupo Eletroacupuntura e Morfina. O volume inspirado de isoflurano foi 58,33% menor no grupo Eletroacupuntura e 22,02% no grupo Morfina quando comparados ao grupo Controle. Pode-se concluir que eletroestimulação dos acupontos Zusanli e Yanglingquan, diminui o volume inspirado de isoflurano e promove estabilidade cardiorrespiratória, sendo superior ao uso da morfina.<br>The aim of this work was to evaluate the morphine and electroacupuncture effects on cardiorespiratory parameters and isoflurane consumption in cats submitted to elective ovariohysterectomy. Eighteen healthy cats were equally distributed in three groups: Electroacupunture, Morphine and Control. Animals were anestethized with acepromazine, propofol and isoflurane. Needles were introduced in false acupoints on animals from Control and Morphine groups, and on Zusanli and Yanglingquan acupoints on Electroacupunture group animals. Electroacupuncture was performed with 2 and 100Hz, square wave. Animals from Morphine group received morphine (0.3mg/kg/im) and Control animals received no treatment. Data were recorded just before acepromazine administration; 10 minutes after acepromazine; after anesthetic induction and stabilization; 30 minutes after electrostimulation beginning or morphine injection; and every 10 minutes for 60 minutes. Variables recorded were: rectal temperature; respiratory frequency; heart rate; oxyhemoglobin partial saturation; mean arterial pressure; total volume of consumed isoflurane; and inspired isoflurane volume. Data were analyzed by MANOVA. Only Electroacupunture animals did not show significant difference between moments for mean arterial pressure, while Electroacupunture and Morphine animals presented better cardiac stability. Compared to Control, the inspired isoflurane volume was decreased in 58.33% on Electroacupunture and 22.01% on GM. It is concluded that electrostimulation of Zusanli and Yanglingquan acupoints in cats submitted to elective ovariohysterectomy decreases the inspired isoflurane volume, leading to cardiorespiratory stability, being superior to morphine

    Ex vivo flexural mechanical properties of bovine bone plates after tibiae osteosynthesis in rabbits

    No full text
    ABSTRACT. Drago M.A., Drago M., Cerqueira H.D.B., Tiburcio M.F., Souza G.B., Barbosa D.H., Santos C.M.L., Silva R.V. & Freitas P.M.C. [Ex vivo flexural mechanical properties of bovine bone plates after tibiae osteosynthesis in rabbits.] Avaliação ex vivo das propriedades mecânicas em flexão de placas ósseas bovina na osteossíntese de tíbias de coelhos. Revista Brasileira de Medicina Veterinária, 37(3):245-249, 2015. Programa de Pós-Graduação em Ciências Veterinárias, Universidade Federal do Espírito Santo (UFES), Alto Universitário, s/nº, Bairro Guararema, Alegre, ES 29500-000, Brasil. E-mail: [email protected] The use of materials produced from bovine bone has been proposed in the manufacture of implants such as pins, plates and screws, due to their osteoinductive and osteoconductive properties or functions of bone graft. However, structural and mechanical aspects must be evaluated prior to the use, in vivo of bone implants. The aim of this study was to evaluate mechanical strength, through a mechanical bending test, of plates produced from bovine cortical bone, used to repair fractures of the tíbia of rabbits ex vivo. Twenty six plates were manufactured from bovine cortical bone and stored in saturated salt solution. Three study groups were used: group GP (n = 10), made up of the bone plates; GTP group (n = 16), rabbit tibia osteotomized and stabilized with bone plates and four screws and Group GT (n = 10), intact tibia. A three-point bending biomechanical test was used to determine the maximum tension, maximum deflection, and stiffness. The results were submitted to Kruskal-Wallis test (p <0.05) and the Dunn test. Comparing GT with the GTP, an 80% reduction was observed in maximum tension. Also noted was a reduction of 87% in maximum tension when comparing GP with GTP. Therefore, the bovine bone plate had a higher maximum tension then the intact rabbit tibia. There was a reduction of 52% in the rigidity of GTP to GT. No significant difference was observed between this force when GPT and GP were compared. There was significant difference among the three groups with respect to maximum deflection, which showed an increase of 100% and 30% in the GTP and GP groups, respectively, when compared to the GT. This study, therefore concluded, that bone plates used to repair fractures of the tibia of rabbits ex vivo presented inferior mechanical properties when compared to intact tibia

    Mecânica e microbiologia de placas produzidas a partir de osso cortical bovino, conservadas em diferentes meios

    No full text
    Objetivou-se com este trabalho avaliar a resistência mecânica de placas ósseas produzidas a partir de osso cortical bovino, conservadas em diferentes meios, e a eficiência desses meios em inibir o crescimento de microrganismos. Foram utilizadas 168 placas confeccionadas a partir de tíbia bovina e conservadas em glicerina a 98%, solução salina a 150%, solução de açúcar a 300%, líquido de Dakin, congeladas em N2L a -196°C, ou esterilizadas em óxido de etileno. Após reidratação em solução de cloreto de sódio a 0,9% por seis horas, elas foram submetidas a ensaios mecânicos de tração, compressão, flexão e torção. Foi realizada avaliação microbiológica das placas anterior e imediatamente após a reidratação, com ou sem adição de enrofloxacina a 0,5%. Não se observou diferença significativa (P<0,01%) da resistência ao ponto de ruptura entre as placas conservadas nos diferentes meios, congeladas-descongeladas ou esterilizadas. Micro-organismos foram isolados das placas conservadas em solução saturada de sal, açúcar, Dakin ou congeladas em N2L, anterior e após a reidratação. Entretanto, após o uso da solução de cloreto de sódio 0,9%, acrescida de enrofloxacina a 0,5%, não foram isolados microrganismos. Portanto, placas de osso bovino, conservadas em solução saturada de açúcar ou sal, glicerina a 98%, solução de Dakin, congeladas em N2L ou esterilizadas em óxido de etileno assemelham-se em relação à biomecânica e a reidratação com solução de cloreto de sódio a 0,9%, acrescida de enrofloxacina a 0,5%, é eficaz no controle do crescimento microbiano.The objective of this study was to evaluate the mechanical strength of bone plates yielded from bovine cortical bone, conserved in different solutions, and the efficiency of these solutions in the inhibition of microorganism's growth. A hundred and sixty eight plates yielded from bovine tibiae were conserved in 98% glycerin, 150% saline solution, 300% sugar solution, Dakin solution, frozen in N2L at - 196°C, or sterilized in ethylene oxide gas. After rehydration in NaCl 0.9% solution for six hours, plates were subjected to tensile, compression, bending and twisting testing. The microbiological evaluation of bone plates was s carried out before and immediately after rehydration, with or without enrofloxacin 0.5% addition. There was no significant difference (P<0.01%) on resistance to the rupture point in plates conserved in different solutions, frozen-thawed or sterilized. Microorganisms were isolated from plates conserved in satured salt solution, sugar satured solution, Dakin solution or frozen in N2L, before and after rehydraion However, after the use of NaCl 0.9% solution added of enrofloxacin 0.5%, microorganisms were not isolated. Therefore, bovine bone plates conserved in sugar or salt satured solution, 98% glycerin, Dakin solution, frozen in N2L or sterilized in ethylene oxide gas present similar biomechanical tests results, and rehydrated with a solution of NaCl 0.9% plus enrofloxacin 0.5% is effective on microorganism growth control

    Acupuntura e analgesia: aplicações clínicas e principais acupontos Acupuncture and analgesia: clinical applications and main acupoints

    No full text
    A dor é uma resposta protetora do organismo a estímulos nocivos, que resulta em efeitos indesejáveis quando não controlada. A analgesia pode ser promovida mediante a utilização de vários tipos de fármacos. No entanto, estes podem causar efeitos adversos de acordo com a espécie e condição física do paciente. A acupuntura tem se mostrado eficaz como coanalgésico pela capacidade de diminuir a quantidade de fármacos utilizados para o controle da dor e raramente ser contraindicada. Objetivou-se com este trabalho fazer uma breve revisão sobre as aplicações clínicas e os efeitos fisiológicos da acupuntura nos mecanismos da dor, bem como demonstrar os principais pontos de acupuntura utilizados para analgesia em animais. A pesquisa foi realizada em bases de dados eletrônicas por palavra-chave, durante o período de março a dezembro de 2008.<br>Pain is a protective response of the body to harmful stimulus, which results in undesirable effects if not controlled. Analgesia can be achieved with the use of different types of drugs. However, these drugs can cause adverse effects according to species and patient physical condition. Acupuncture has been proved to be an effective analgesic adjuvant, by the capacity to decrease the amount of drug used for pain control, rarely contra-indicated. The aim of this paper was to review the physiological effects of acupuncture on pain mechanisms, and demonstrate the main acupoints used for animal analgesia. The search was done in electronic search database using key words, in 2008
    corecore