207 research outputs found

    Transdifferentiation of pancreatic progenitor cells to hepatocyte-like cells is not serum-dependent when facilitated by extracellular matrix proteins

    Get PDF
    The rising prevalence of chronic liver disease, coupled with a permanent shortage of organs for liver transplantation, has sparked enormous interest in alternative treatment strategies. Previous protocols to generate hepatocyte-like cells (HLCs) via pancreas-to-liver transdifferentiation have utilised fetal bovine serum, introducing unknown variables and severely limiting study reproducibility. Therefore, the main goal of this study was to develop a protocol for transdifferentiation of pancreatic progenitor cells to HLCs in a chemically defined, serum-free culture medium. The clonal pancreatic progenitor cell line AR42J-B13 was cultured in basal growth medium on uncoated plastic culture dishes in the absence or presence of Dexamethasone on uncoated, laminin-or fibronectin-coated culture substrata, with or without serum supplementation. The hepatocytic differentiation potential was evaluated: (i) morphologically through bright-field and scanning electron microscopy, (ii) by assessing pancreatic and hepatic marker expression and (iii) by determining the function of HLCs through their ability to synthesise glycogen or take up and release indocyanine green. Here we demonstrate for the first time that transdifferentiation of pancreatic cells to HLCs is not dependent on serum. These results will assist in converting current differentiation protocols into procedures that are compliant with clinical use in future cell-based therapies to treat liver-related metabolic disorders

    Computer‐assisted bone augmentation, implant planning and placement: An in vitro investigation

    Get PDF
    Aim To assess in vitro the workflow for alveolar ridge augmentation with customised 3D printed block grafts and simultaneous computer-assisted implant planning and placement. Methods Twenty resin mandible models with an edentulous area and horizontal ridge defect in the region 34–36 were scanned with cone beam computed tomography (CBCT). A block graft for horizontal ridge augmentation in the region 34–36 and an implant in the position 35 were digitally planned. Twenty block grafts were 3D printed out of resin and one template for guided implant placement were stereolithographically produced. The resin block grafts were positioned onto the ridge defects and stabilised with two fixation screws each. Subsequently, one implant was inserted in the position 35 through the corresponding template for guided implant placement. Optical scans of the study models together with the fixated block graft were performed prior to and after implant placement. The scans taken after block grafting were superimposed with the virtual block grafting plan through a best-fit algorithm, and the linear deviation between the planned and the achieved block positions was calculated. The precision of the block fixation was obtained by superimposing the 20 scans taken after grafting and calculating the deviation between the corresponding resin blocks. The superimposition between the scans taken after and prior to implant placement was performed to measure a possible displacement in the block position induced by guided implant placement. The (98–2%)/2 percentile value was determined as a parameter for surface deviation. Results The mean deviation in the position of the block graft compared to the virtual plan amounted to 0.79 ± 0.13 mm. The mean deviation between the positions of the 20 block grafts measured 0.47 ± 0.2 mm, indicating a clinically acceptable precision. Guided implant placement induced a mean shift of 0.16 ± 0.06 mm in the position of the block graft. Conclusions Within the limitations of this in vitro study, it can be concluded that customised block grafts fabricated through CBCT, computer-assisted design and 3D printing allow alveolar ridge augmentation with clinically acceptable predictability and reproducibility. Computer-assisted implant planning and placement can be performed simultaneously with computer-assisted block grafting leading to clinically non-relevant dislocation of block grafts

    PP-waves with torsion and metric-affine gravity

    Full text link
    A classical pp-wave is a 4-dimensional Lorentzian spacetime which admits a nonvanishing parallel spinor field; here the connection is assumed to be Levi-Civita. We generalise this definition to metric compatible spacetimes with torsion and describe basic properties of such spacetimes. We use our generalised pp-waves for constructing new explicit vacuum solutions of quadratic metric-affine gravity.Comment: 17 pages, LaTeX2

    Whole-body magnetic resonance imaging in pediatric oncology — recommendations by the Oncology Task Force of the ESPR

    Get PDF
    The purpose of this recommendation of the Oncology Task Force of the European Society of Paediatric Radiology (ESPR) is to indicate reasonable applications of whole-body MRI in children with cancer and to address useful protocols to optimize workflow and diagnostic performance. Whole-body MRI as a radiation-free modality has been increasingly performed over the last two decades, and newer applications, as in screening of children with germ-line mutation cancer-related gene defects, are now widely accepted. We aim to provide a comprehensive outline of the diagnostic value for use in daily practice. Based on the results of our task force session in 2018 and the revision in 2019 during the ESPR meeting, we summarized our group’s experiences in whole-body MRI. The lack of large evidence by clinical studies is challenging when focusing on a balanced view regarding the impact of whole-body MRI in pediatric oncology. Therefore, the final version of this recommendation was supported by the members of Oncology Task Force

    An examination of the temporal and geographical patterns of psychiatric emergency service use by multiple visit patients as a means for their early detection

    Get PDF
    <p>Abstract</p> <p>Background:</p> <p>Frequent users of the psychiatric emergency service (PES) place a heavy burden upon the mental health care delivery system. The aim of this study was to identify distinct temporal or geographical patterns of PES use by these patients as potential markers for their early detection.</p> <p>Methods:</p> <p>Diagnostic profiles were obtained for patients making an intermediate (4 to 10) or a high (11 or more) number of visits to a general hospital PES in Montreal (Canada) between 1985 and 2004. Between-group comparisons were made with regards to several parameters. These included the time intervals between consecutive visits, visit clustering (single, repeating, and the time interval to the first cluster) and visits made to three other services where data was similarly acquired from 2002 to 2004.</p> <p>Results:</p> <p>The two multiple visit groups differed with regards to diagnostic profiles and actual time between consecutive visits (significantly shorter in patients with 11 or more visits). Patients with 11 or more visits were more likely to have a single cluster (3 or more visits/3 months) or repeating clusters (4 visits/3 months) in their patterns of use. Personality disorders were more prevalent in patients with single clusters as they were, along with schizophrenia, in those with repeating clusters. In addition, clusters were found to occur sufficiently early so as to be potentially useful as markers for early detection. Ten percent of those with 11 or more visits and 16% of those with an intermediate number of visits frequented at least one other PES. A small number of patients, primarily those with substance abuse, made over 50% of their visits to other services.</p> <p>Conclusion:</p> <p>Temporal and geographical patterns of use differed significantly between the multiple visit groups. These patterns, combined with distinct diagnostic profiles, could potentially lead to the more rapid identification and treatment of specific sub-groups of multiple visit patients.</p

    Transcatheter aortic valve implantation in failed bioprosthetic surgical valves.

    Get PDF
    IMPORTANCE: Owing to a considerable shift toward bioprosthesis implantation rather than mechanical valves, it is expected that patients will increasingly present with degenerated bioprostheses in the next few years. Transcatheter aortic valve-in-valve implantation is a less invasive approach for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed. OBJECTIVE: To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves. DESIGN, SETTING, AND PARTICIPANTS: Correlates for survival were evaluated using a multinational valve-in-valve registry that included 459 patients with degenerated bioprosthetic valves undergoing valve-in-valve implantation between 2007 and May 2013 in 55 centers (mean age, 77.6 [SD, 9.8] years; 56% men; median Society of Thoracic Surgeons mortality prediction score, 9.8% [interquartile range, 7.7%-16%]). Surgical valves were classified as small (≤21 mm; 29.7%), intermediate (&gt;21 and &lt;25 mm; 39.3%), and large (≥25 mm; 31%). Implanted devices included both balloon- and self-expandable valves. MAIN OUTCOMES AND MEASURES: Survival, stroke, and New York Heart Association functional class. RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83.2% (95% CI, 80.8%-84.7%; 62 death events; 228 survivors). Patients in the stenosis group had worse 1-year survival (76.6%; 95% CI, 68.9%-83.1%; 34 deaths; 86 survivors) in comparison with the regurgitation group (91.2%; 95% CI, 85.7%-96.7%; 10 deaths; 76 survivors) and the combined group (83.9%; 95% CI, 76.8%-91%; 18 deaths; 66 survivors) (P = .01). Similarly, patients with small valves had worse 1-year survival (74.8% [95% CI, 66.2%-83.4%]; 27 deaths; 57 survivors) vs with intermediate-sized valves (81.8%; 95% CI, 75.3%-88.3%; 26 deaths; 92 survivors) and with large valves (93.3%; 95% CI, 85.7%-96.7%; 7 deaths; 73 survivors) (P = .001). Factors associated with mortality within 1 year included having small surgical bioprosthesis (≤21 mm; hazard ratio, 2.04; 95% CI, 1.14-3.67; P = .02) and baseline stenosis (vs regurgitation; hazard ratio, 3.07; 95% CI, 1.33-7.08; P = .008). CONCLUSIONS AND RELEVANCE: In this registry of patients who underwent transcatheter valve-in-valve implantation for degenerated bioprosthetic aortic valves, overall 1-year survival was 83.2%. Survival was lower among patients with small bioprostheses and those with predominant surgical valve stenosis
    corecore