498 research outputs found

    Women Writers of the Middle Ages

    Get PDF

    A solution to the slow stabilisation of surface pressure sensors based on the Wilhelmy method

    Get PDF
    Dynamic measurement of surface pressure is of particular interest in the field of Langmuir monolayers, where the change in surface pressure throughout an experiment can provide information on the properties of the monolayer forming material, or on the reaction kinetics of the monolayer’s interaction with other materials. One of the most common methods for the measurement of dynamic surface pressure is the Wilhelmy plate method. This method measures changes in the forces acting upon a thin plate of material at the air-water interface; this measurement is then converted to surface pressure. One version of this method, which uses filter paper plates at the air-water interface, is particularly popular due to their relatively low cost. However, it has been seen that the use of filter paper plates attached to a Wilhelmy balance requires an initial stabilisation period lasting several hours, during which the readings drift from the original baseline. Here the cause of this drift is explored, considering how changes in the weight of the plate over time influence the assumptions on which the surface pressure is derived from the measurements made by the Wilhelmy balance. A simple method for preventing this drift through pre-soaking of the filter paper plates is presented

    Dissolved oxygen sensing using an optical fibre long period grating coated with hemoglobin

    Get PDF
    A long period grating fiber optic sensor coated with hemoglobin is used to detect dissolved oxygen. The sensitivity of this sensor to the ratio of dissolved carbon dioxide to dissolved oxygen is demonstrated via the conversion of carboxyhemoglobin to oxyhemoglobin on the sensor surface. The sensor shows good repeatability with a %CV of less than 1% for carboxyhemoglobin and oxyhemoglobin states with no measurable drift or hysteresis

    Overwrite fabrication and tuning of long period gratings

    Get PDF
    The central wavelengths of the resonance bands are critical aspect of the performance of long period gratings (LPGs) as sensors, particularly for devices designed to operate near the phase matching turning point (PMTP), where the sensitivity to measurements can vary rapidly. Generally, LPGs are characterized by their period, but the amplitude of the amplitude of the index modulation is also an important factor in determining the wavelengths of the resonance bands. Variations in fabrication between LPG sensors can increase or decrease the sensitivity of the LPG to strain, temperature or surrounding refractive index. Here, the technique of overwritten UV laser fabrication is demonstrated. It is shown that, on repeated overwriting, the resonance bands of an LPG exhibit significant wavelength shift, which can be monitored and which can be used to tune the resonance bands to the desired wavelengths. This technique is applied to periods in the range 100 to 200 µm, showing the cycle-to-cycle evolution of the resonance bands near the PMTPs of a number of cladding modes. The use of online monitoring is shown to reduce the resonance band sensor-to-sensor central wavelength variation from 10 nm to 3 nm

    Fabrication and optimisation of a fused filament 3D-printed microfluidic platform

    Get PDF
    A 3D-printed microfluidic device was designed and manufactured using a low cost ($2000) consumer grade fusion deposition modelling (FDM) 3D printer. FDM printers are not typically used, or are capable, of producing the fine detailed structures required for microfluidic fabrication. However, in this work, the optical transparency of the device was improved through manufacture optimisation to such a point that optical colorimetric assays can be performed in a 50 µl device. A colorimetric enzymatic cascade assay was optimised using glucose oxidase and horseradish peroxidase for the oxidative coupling of aminoantipyrine and chromotropic acid to produce a blue quinoneimine dye with a broad absorbance peaking at 590 nm for the quantification of glucose in solution. For comparison the assay was run in standard 96 well plates with a commercial plate reader. The results show the accurate and reproducible quantification of 0–10 mM glucose solution using a 3D-printed microfluidic optical device with performance comparable to that of a plate reader assay

    Accurate ab initio calculations which demonstrate a 3 Pi u ground state for Al2

    Get PDF
    The spectroscopic parameters and separations between the three low-lying X 3 Pi u, A 3 Sigma g -, and a 1 Sigma g + states of Al2 are studied as a function of both the one-particle and n-particle basis set. Approximate correlation treatments are calibrated against full Cl calculations correlating the six valence electrons in a double-zeta plus two d-function basis set. Since the CASSCF/MRCI 3 Pi u to 3 Sigma g - separation is in excellent agreement wtih the FCI value, the MRCI calculations were carried out in an extended (20s13p6d4f)/(6s5p3d2f) gaussian basis. Including a small correction for relativistic effects, the best estimate is that 3 Sigma g - state lies 174/cm above the 3 Pi u ground state. The 1 Sigma g + state lies at least 2000/cm higher in energy. At the CPF level, inclusion of 2s and 2p correlation has little effect on D sub e, reduces T sub e by only 26/cm, and shortens the bond lengths by about 0.02 a sub o. Further strong support for a 3 Pi u ground state comes from the experimental absorption spectra, since both observed transitions can be convincingly assigned as 3 Pi u yields 3 Pi g. The (2) 3 Pi g state is observed to be sensitive to the level of correlation treatment, and to have its minimum shifted to shorter rho values, such that the strongest experimental absorption peak probably corresponds to the 0 yields 2 transition

    Radio source contributions to the microwave sky

    Get PDF

    Use of microfasteners to produce damage tolerant composite structures

    Get PDF
    The paper concerns the mechanical performance of continuous fibre/thermosetting polymer matrix composites reinforced in the through-thickness direction with fibrous or metallic rods or threads in order to mitigate against low delamination resistance. Specific illustrations of the effects of microfasteners in reducing delamination crack growth are made for Z-pinned and tufted composites. Response to loading in such ‘structured materials’ is subject to multiple parameters defining their in-plane and out-of-plane properties. Single microfastener mechanical tests are well suited to establish the crack bridging laws under a range of loading modes, from simple delamination crack opening to shear, and provide the basis for predicting the corresponding response of microfastener arrays, within a given material environment. The fundamental experiments on microfasteners can be used to derive analytical expressions to describe the crack bridging behaviour in a general sense, to cover all possible loadings. These expressions can be built into cohesive element constitutive laws in a finite-element framework for modelling the effects of microfastener arrays on the out-of-plane mechanical response of reinforced structural elements, including the effects of known manufacturing imperfections. Such predictive behaviour can then be used to assess structural integrity under complex loading, as part of the component design process. This article is part of the themed issue ‘Multiscale modelling of the structural integrity of composite materials’

    Modifying monolayer behaviour by incorporating subphase additives and improving Langmuir–Blodgett thin film deposition on optical fibres

    Get PDF
    Experiments showing the possibility of modifying the behaviour of calix[4]resorcinarene monolayers at the air–water interface and optimising the deposition of multilayer coatings onto optical fibres are presented. The nature of the subphase is fundamental to the behaviour of monolayers and their utility in coating and sensing applications. Here we show initial studies exploring the modification of the calix[4]resorcinarene monolayer–water interaction through the introduction of dipole altering alcohol additives to the aqueous subphase. We explored the effect of this modification for three small alcohols. The resulting isotherms of the materials showed a reduction in the surface pressure and area per molecule required in order for the monolayer to reach its point of collapse. Incorporation of alcohols shifted the point of collapse, leading to the application of ethanol being successful in improving the transfer of material via Langmuir–Blodgett coating onto optical fibres at lower pressures. This method may prove useful in allowing greater control over future sensor surface coatings
    • …
    corecore