46 research outputs found
A pletismografia optoeletrônica é um instrumento válido para medir a capacidade inspiratória?
The aim of this study was to evaluate the concurrent validity of the optoelectronic plethysmography (OEP) to measure inspiratory capacity (IC) at rest and during submaximal exercise in healthy subjects. Twelve subjects (6 Male/6 Female; 23.8±1.34 yrs) with normal body mass index and lung function completed the study protocol. Participants were assessed at rest and during a 12-minute submaximal exercise protocol on a cycle ergometer. IC maneuvers were simultaneously recorded by OEP system and by a spirometer at rest and during exercise. The percentage of discrepancy between measurements, linear regression analysis and Bland-Altman method were used for data analysis. The study was approved by the institution ethics committee. It was considered 150 valid IC maneuvers for analysis (44 for resting and 106 for exercise). The percentage of discrepancy between the measurements were -9.6 (8.6%) at rest and -4.6 (5.5%) during exercise. Regression analysis showed good linear associations between methods at rest (r2=0.90; p=0.0002) and during exercise (r2=0.96; p=0.0008). Bland-Altman analysis using data obtained during exercise showed a bias between the two methods of 0.13L. The limits of agreement indicate that the difference between methods can vary from -0.04L to 0.57L. Additionally, data was equally distributed between the upper and lower limits, demonstrating no systematic overestimation or underestimation of the IC by any of the instruments. In conclusion, this study demonstrated that the OEP is a valid evaluation system to measure IC of healthy individuals at rest and during submaximal exercise.Este estudio tiene como propósito evaluar la validez de la pletismografÃa optoelectrónica (OEP) para medir la capacidad inspiratoria (CI) en sujetos saludables tanto en reposo como durante ejercicio submáximo. Participaron de este estudio 12 sujetos (6 hombres y 6 mujeres; 23,8 ± 1,34 años de edad) con Ãndice de masa corporal y función pulmonar normales. Los participantes fueron evaluados en reposo por 7 minutos y durante 12 minutos de ejercicio submáximo en bicicleta estática. Se grabaron simultáneamente por la OEP y por un espirómetro las maniobras de la CI tanto en reposo como durante el ejercicio. Se utilizaron el porcentaje de discrepancia en las mediciones, el análisis de regresión lineal y el método Bland-Altman para análisis de datos del estudio, el que fue aprobado por el comité de ética de la institución. Se consideró 150 maniobras CI para el análisis, las cuales 44 fueron para reposo y 106 para ejercicio. El porcentaje de discrepancia entre las medidas fue del -9,6 (un 8,6%) en reposo y del -4,6 (un 5,5%) durante el ejercicio. El análisis de regresión lineal mostró asociaciones para los métodos en reposo (r2=0,90; p=0,0002) y durante el ejercicio (r2 = 0,96; p = 0,0008). Los datos obtenidos durante el ejercicio utilizándose el análisis Bland-Altman mostraron un sesgo de 0.13L entre los métodos. Los lÃmites de concordancia indicaron que la diferencia entre los métodos puede tener variación desde -0.04L hasta 0.57L. Además, se distribuyeron por igual los datos entre los lÃmites de concordancia, los cuales no mostraron sobreestimación o subestimación sistemática de la CI. En conclusión, este estudio mostró que el OEP es un sistema de evaluación valido para medir la CI de sujetos saludables tanto en reposo como durante ejercicio submáximo.O objetivo deste estudo foi avaliar a validade concorrente da pletismografia optoeletrônica (POE) para medir a capacidade inspiratória (CI) de indivÃduos saudáveis no repouso e durante exercÃcio submáximo. Doze voluntários (6 H/6 M; 23,8±1,34 anos) com Ãndice de massa corporal e prova de função pulmonar normais completaram o protocolo do estudo. Eles foram avaliados no repouso (7 minutos) e durante 12 minutos de exercÃcio submáximo em cicloergômetro. A CI foi mensurada simultaneamente pela POE e por um espirômetro. A porcentagem de discrepância entre as medidas, a análise de regressão linear e o método de Bland-Altman foram utilizados para análise. O estudo foi aprovado pelo comitê de ética em pesquisa da instituição. Foram consideradas 150 manobras de CI válidas para análise (44 para o repouso e 106 para o exercÃcio). A porcentagem de discrepância entre as medidas foi de -9,6 (8,6%) no repouso e -4,6 (5,5%) durante o exercÃcio. A análise de regressão linear mostrou associações entre os dois métodos no repouso (r2=0,90; p=0,0002) e durante o exercÃcio (r2=0,96; p=0,0008). A análise de Bland-Altman realizada com os dados do exercÃcio mostrou viés entre os métodos de 0,13L. Os limites de concordância mostraram que a diferença entre os métodos pode variar de -0,04 L to 0,57 L. Adicionalmente, os dados distribuÃram-se igualmente entre os limites de concordância, sem superestimação ou subestimação sistemática da CI. Em conclusão, o estudo demonstrou que a POE é um sistema válido para mensuração da CI de indivÃduos saudáveis no repouso e durante o exercÃcio submáximo
Pressões respiratórias máximas: equipamentos e procedimentos usados por fisioterapeutas brasileiros
Measuring maximal respiratory pressures - a method for assessing respiratory muscle strength - is a voluntary, effort-dependent test broadly used for diagnostic and therapeutic purposes. There is a large variety of devices and interfaces available to perform this procedure, which leads to a relative absence of standardization. The aim of this survey was to ascertain devices, procedures and interpretation parameters used in measuring maximal respiratory pressures among Brazilian physical therapists. Nineteen respiratory physical therapists, in charge at 13 institutions in three regions of the country, answered a questionnaire on those issues. Results show prevalence of use of analogue respiratory pressure meters (60%), with a silicon tube (60%) and a cylindrical mouthpiece (53,4%) with 1- to 2-mm diameter air-leak opening, associated to use of nose clip (100%). When measuring, they perform a minimum of three acceptable and reproducible tests (80%), and in analysing pressure values all of them use reference values or predictive equations. Data suggest a relative uniformity in measuring maximal respiratory pressures among Brazilian physical therapists.A mensuração das pressões respiratórias máximas - método de avaliação das condições de força dos músculos respiratórios - é um teste voluntário e esforço-dependente, com aplicações clÃnicas de ordem diagnóstica e terapêutica. Há uma grande variedade de equipamentos e interfaces para sua execução, o que acarreta uma relativa ausência de padronização. O objetivo deste estudo foi identificar os diferentes equipamentos, procedimentos e forma de interpretar a mensuração das pressões respiratórias máximas entre fisioterapeutas brasileiros. Dezenove fisioterapeutas respiratórios, de 13 diferentes instituições, situadas em três regiões do paÃs, responderam a um questionário sobre esses aspectos. Os resultados mostram que prevaleceu o uso de manovacuômetro analógico (60%), com tubo de silicone (60%) e interface do tipo bocal tubular (53,4%), contendo orifÃcio de fuga de 1 a 2 mm de diâmetro (86,6%), associado ao uso de clipe nasal (100%). Na mensuração, foi observado um número mÃnimo de três testes aceitáveis e reprodutÃveis (80%) e, para a análise dos valores encontrados, todos usam valores de referência ou equações preditivas. Os dados sugerem que existe uma relativa uniformidade em relação à mensuração das pressões respiratórias máximas entre fisioterapeutas brasileiros
Reabilitação pulmonar na unidade de terapia intensiva: revisão de literatura
The long period of immobility in intensive care units (ICU) may be harmful to patients' musculoskeletal, cardiovascular, respiratory and neurological systems. Pulmonary rehabilitation in ICU, particularly the physical training, aims to restore previous functionality prior to the event that determined the need for mechanical ventilation, thus reducing dependence, preventing new admissions, and improving patients' quality of life. However, resistance has been noticed among ICU staff to applying physical training. The purpose of this study was to perform a literature review on the implications of pulmonary rehabilitation programs in the ICU. Articles were sought for in PubMed, Cochane, PEDro and SciELO databases, by means of key words"pulmonary rehabilitation", "intensive care", and"intensive therapy", in addition to studies suggested by experts. Seven articles (randomised clinical trials, cohort, and retrospective studies) were assessed. All of them suggested benefits by pulmonary rehabilitation in the ICU, in addition to the absence of side effects. Main benefits were ambulation improvement, increase on strength of respiratory and skeletal muscles, plus improvement in activities of daily living. According to the studies analyzed, pulmonary rehabilitation in the ICU proves to be beneficial to patients, being a safe and well tolerated means of rehabilitation.O longo perÃodo de imobilidade na internação em unidade de terapia intensiva (UTI) desencadeia prejuÃzos aos sistemas musculoesquelético, cardiovascular, respiratório e neurológico. A reabilitação pulmonar na UTI, em especial o treinamento fÃsico, visa restaurar a funcionalidade anterior ao episódio que determinou a necessidade da ventilação mecânica, reduzindo a dependência, prevenindo novas internações e, conseqüentemente, melhorando a qualidade de vida. Entretanto, é observada resistência na aplicação dessa modalidade de tratamento, devido ao receio das equipes. O objetivo do presente estudo foi efetuar uma revisão da literatura sobre as implicações dos programas de reabilitação pulmonar nas UTI. O levantamento bibliográfico foi feito nas bases de dados PubMed, Cochrane, PEDro e SciELO por meio dos descritores"reabilitação pulmonar""no cuidado intensivo" e"na unidade de terapia intensiva", além de estudos sugeridos por especialistas. Sete artigos (ensaios clÃnicos randomizados, estudos de coorte e retrospectivos) foram avaliados. Todos sugeriram que a reabilitação na UTI é benéfica e não causa efeitos colaterais. Os principais benefÃcios identificados foram a melhora da deambulação, aumento de força da musculatura respiratória e esquelética, além de melhora funcional ligada à s atividades de vida diária. De acordo com os estudos analisados, a reabilitação pulmonar em UTI mostrou-se uma modalidade segura, bem tolerada e que determina efeitos positivos aos pacientes
Os efeitos da estimulação elétrica nervosa transcutânea no pós-operatório de cirurgias torácicas e abdominais: revisão de literatura e relato de casos
The purpose of this study is to review the literature concerning the effects of transcutaneous eletric nerve stimulation (TENS) following major thoracic and abdominal surgeries. TENS has been used as a complementary analgesics for pain relief after surgery. We described the use of TENS in patients undergoing laparotomy at the Clinical Hospital of Universidade Federal de Minas Gerais. Four patients were enrolled in this observation. Patients were evaluated on day before surgery and on the first and secondpostoperative days. TENS using conventional modulation was performedtwice a day, during thirty minutes. Visual Analogue Standardized Scale assessed pain. Patient number 1 had impairments on pulmonary function as described on the literature, with decreases in FEV, FVC FEF/FVC and peak-flow after surgery. The results observed on patient number 2 showed increase of values on the first postoperative day followed by decrease, close to the obtained on the preoperative evaluation. All patients showed decrease of pain associated with movement. This improvement is in accord with the hypothesis about the effectiveness of TENS on the control of pain related to voluntary movement, not necessarily on pain from organ origin. The use of TENS leads to a best patient's cooperation, which is very important to reach the therapeutics and functional goals during physical therapy.O objetivo deste estudo é fazer uma revisão da literatura sobre a influência da estimulação elétrica nervosa transcutânea (TENS) no pós-operatório de cirurgias torácicas e abdominais. Nós relatamos o uso da eletroestimulação em quatro pacientes submetidas a laparotomias noHospital das ClÃnicas da Universidade Federal de Minas Gerais. As pacientes foram avaliadas no perÃodo pré-operatório e acompanhadas no I o e 2 o dia de pós-operatório (DPO). As duas pacientes submetidas a cirurgias supra-umbilicais realizaram prova de função pulmonar. A TENS foi aplicada na modulação convencional duas vezes ao dia durante trinta minutos. A dor foi mensurada através de uma Escala Visual Analógica Padronizada. Pôde-se observar que a paciente n° 1 apresentou alteraçõesespirométricas similares ao encontrado na literatura revisada, havendo diminuição dos valores de VEFi, CVF, VEF,/CVF e peakflow nos dias subseqüentes à cirurgia. Os resultados obtidos na espirometria da paciente n° 2 demonstraram que houve aumento nos valores no 1 ° DPO, com queda subseqüente no 2o DPO, valores estes próximos aos obtidos no pré-operatório. Todas as pacientes relataram melhora da dor à movimentação. Esta observação coincide com a hipótese de que a TENS irá atuar de maneira eficaz na dor de origem cutânea, relacionada a movimentos voluntários, não sendo necessariamente eficiente para doresde origem visceral. Foi observado que o uso da TENS viabiliza, em determinadas circunstâncias uma maior cooperação por parte do paciente, fator crucial para que possam ser atingidos os objetivos terapêuticos e funcionais do atendimento fisioterápico
Reprodutibilidade teste-reteste e validade concorrente de manovacuômetro digital
A manovacuometria é um teste simples, rápido e não invasivo que mensura as pressões respiratórias máximas (PRM). Diretrizes recomendam o uso do manovacuômetro digital devido à sua alta precisão. O objetivo deste estudo foi avaliar a reprodutibilidade teste-reteste e a validade concorrente de um manovacuômetro digital na mensuração das pressões inspiratórias e expiratórias máximas (PImáx e PEmáx) e da pressão inspiratória nasal durante o fungar (SNIP). Foram avaliados 30 indivÃduos saudáveis (20-30 anos) utilizando os manovacuômetros digitais UFMG e MicroRPM(r) (Micro Medical, UK). Para avaliar a reprodutibilidade, foi utilizado o Coeficiente de Correlação Intraclasse (CCI) e teste t de student para amostras dependentes. Para análise da validade foram utilizados: a correlação de Pearson, o teste t de student para amostras dependentes, a análise de regressão linear e o método Bland-Altman. O nÃvel de significância considerado foi de 5% (p;0,05). A correlação entre os valores observados nos dois instrumentos foi de alta magnitude para todas as variáveis (0,82 a 0,85); não houve diferença significativa entre os valores médios obtidos nos dois instrumentos (p>;0,05); foi observada forte associação entre as medidas das PRM obtidas pelos dois métodos e a análise de Bland-Altman não demonstrou superestimação ou subestimação sistemática das PRM e do SNIP. Em conclusão, os resultados sugerem que o manovacuômetro UFMG é confiável e válido para avaliação das PRM e SNIP em indivÃduos saudáveis.The manovacuometer is a simple, quick and non-invasive test which measures the maximal respiratory pressures (MRS). Guidelines recommend the use of a digital manovacuometer due to its high accuracy. The purpose of this study was to assess the test-retest reliability and concurrent validity of a digital manovacuometer in measuring the maximal inspiratory and expiratory pressures (MIP/MEP) and nasal inspiratory pressure while sniffing (SNIP). A total of 30 healthy subjects were assessed (20-30 years old) using the UFMG and MicroRPM(r) (Micro Medical, UK) digital manovacuometers. To assess reliability, Intraclass Correlation Coefficient (ICC) and Student's t test it was used for dependent samples. For the validity assessment, the following were used: Pearson correlation, Student's t test for dependent samples, linear regression and the Bland-Altman method. The level of significance was set at 5% (p;0.05); the correlation between observed values from the two instruments was of high magnitude for all variables (0.82 to 0.85); no significant difference was found between the values obtained for both instruments (p>;0.05); a strong association was observed between measures of MIP and MEP obtained by the two methods and Bland-Altman analysis showed no systematic overestimation or underestimation of maximal respiratory pressures and SNIP. In conclusion, the results suggest that the UFMG manovacuometer is a reliable and valid instrument for assessing MIP, MEP and SNIP in healthy subjects.La manovacuometrÃa es una prueba sencilla, rápida y no invasiva que mide las presiones respiratorias máximas (PRM). Directrices recomiendan el uso del manuvacuómetro digital debido a su alta precisión. El objetivo de este estudio fue evaluar la reproducibilidad test-retest y la validez concurrente de un manuvacuómetro digital para medir las presiones inspiratoria y espiratoria máximas (PImáx y PEmáx) y de la presión inspiratoria nasal durante la aspiración (SNIP). Se evaluaron 30 sujetos sanos (20-30 años) por medio de los manovacuómetros digitales UFMG y MicroRPM(r) (Micro Medical, UK). Para evaluar la reproducibilidad, se utilizó el coeficiente de correlación intraclase (CCI) y el test t de student para muestras dependientes. Para el análisis de la validez se utilizaron: la correlación de Pearson, el test t de student para muestras dependientes, el análisis de regresión lineal y el método Bland-Altman. El nivel de significación considerado fue del 5% (p;0,05). La correlación entre los valores observados en los dos instrumentos fue de alta magnitud para todas las variables (0,82 a 0,85); no hubo diferencia significativa entre los valores medios obtenidos en los dos instrumentos (p>;0,05); Se observó una fuerte asociación entre las medidas de las PRM obtenidas por los dos métodos y el análisis de Bland-Altman no demostró sobreestimación o subestimación sistemática de las PRM y del SNIP. En conclusión, los resultados sugieren que el manovacuómetro UFMG es fiable y válido para la evaluación de las PRM y SNIP en sujetos sanos
Cough peak flow in preschoolers: success rate and test-retest reproducibility
La evaluación de la función pulmonar en niños en edad preescolar es importante pues hay pocos estudios que investigan los test de función pulmonar en este grupo. Este estudio tuvo el propósito de evaluar la tasa de éxito y la reproducibilidad test-retest del pico de flujo de tos (PFT) en una muestra con niños entre 4 y 6 años de edad. Se estudió el PFT en 44 participantes saludables (26 chicos y 18 chicas) elegidos a través de un cuestionario ATS-DLD-78-C para detectar la presencia de enfermedades respiratorias de base y exposición ambiental. Se utilizó el medidor del pico de flujo espiratorio (Piko-I Electronic Peak Flow Meter, Pulmonary Data Services, USA) para medir el PFT. Se definió la tasa de éxito como el porcentaje de niños capaces de realizar el test según los criterios de aceptabilidad y de reproducibilidad. Para evaluar la reproducibilidad test-retest tras tres semanas se reevaluaron 10 niños según el cálculo de la muestra. Se analizó la reproducibilidad a través del test t pareado, considerando significativoÉ importante avaliar a função pulmonar em pré-escolares. Poucos estudos relacionados aos testes de função pulmonar nessa população estão disponÃveis. O objetivo deste estudo foi avaliar a taxa de sucesso e reprodutibilidade teste-reteste do pico de fluxo da tosse (PFT) em uma amostra de crianças com idade entre 4 e 6 anos. O PFT foi estudado em 44 crianças saudáveis (26 meninos e 18 meninas), selecionadas de acordo com o questionário ATS-DLD-78-C, utilizado para detectar a presença de doenças respiratórias de base e exposição ambiental. O medidor de pico de fluxo expiratório (Piko-I Electronic Peak Flow Meter, Pulmonary Data Services, USA) foi usado para mensurar o PFT. A taxa de sucesso foi definida como a porcentagem de crianças capazes de realizar o teste de acordo com os critérios de aceitabilidade e reprodutibilidade. Para avaliar a reprodutibilidade teste-reteste, 10 crianças (de acordo com o cálculo amostral) foram reavaliadas após três semanas. A reprodutibilidade teste-reteste foi avaliada pelo teste t pareado, considerando significativo pIt is important to evaluate lung function in preschoolers. There are few studies related to pulmonary function tests with this part of the population. The purpose of this study was to evaluate the success rate and test-retest reproducibility of the cough peak flow (CPF) in a sample with children between four and six years old. The CPF was tested in 44 healthy children (26 boys, 18 girls), selected according to the ATS-DLD-78-C questionnaire, used to detect the presence of common respiratory diseases or induced by environmental exposure. An expiratory peak flow meter (Piko-I Electronic Peak Flow Meter, Pulmonary Data Services, USA) was used to measure CPF. The success rate was defined as the percentage of children able to perform the test according to the acceptability and reproducibility criteria. To evaluate the test-retest reproducibility, 10 children (according with the sample calculation) were reevaluated after three weeks. The study was approved by the Ethics Research Committee of the Institution. The test-retest reproducibility was evaluated by the paired t-test, considering a significance of
Equação de predição para o miniexame do estado mental: influência da educação, idade e sexo
O mini-exame do estado mental (MEEM) é um teste de rastreio mundialmente utilizado para identificar alterações no âmbito da cognição. Estudos têm demonstrado a influência da educação, idade e gênero na pontuação do MEEM. No entanto, no Brasil, os estudos consideram apenas um fator para a pontuação no teste. O objetivo do estudo foi estabelecer uma equação preditiva para o MEEM. Um estudo transversal exploratório foi desenvolvido e examinadores treinados avaliaram participantes da comunidade. Os voluntários foram avaliados pelo MEEM e pela Escala de Depressão Geriátrica (EDG). A pontuação do MEEM foi a variável dependente. A idade, nÃvel educacional, gênero e pontuação na EDG foram as variáveis independentes. A análise de regressão multivariada foi utilizada para determinar o modelo de melhor valor preditivo para os escores do MEEM. Foram avaliados 250 indivÃduos entre 20 e 99 anos, sem comprometimento cognitivo. O nÃvel educacional, a idade e o sexo explicaram 38% da variância total da pontuação do MEEM (p<0,0001) e resultaram na equação: MEEM=23,350+0,265(anos de escolaridade)-0,042(idade)+1,323(gênero), em que mulher=1 e homem=2. A pontuação do MEEM pode ser melhor explicada e predita quando o nÃvel educacional, idade e gênero são considerados. Os resultados contribuem para o conhecimento sobre as variáveis que influenciam o escore do MEEM, bem como fornece uma maneira de considerá-las na pontuação do teste, proporcionando uma melhor triagem desses pacientes.El mini-examen del estado mental (MEEM) es una prueba de rastreo mundialmente utilizada para identificar alteraciones en el ámbito de la cognición. Los estudios han demostrado la influencia de la educación, la edad y el sexo en la puntuación del MEEM. Sin embargo, en Brasil, los estudios consideran sólo un factor para la puntuación en la prueba. El objetivo del estudio fue establecer una ecuación predictiva para el MEEM. Un estudio transversal exploratorio fue desarrollado y examinadores entrenados evaluaron a participantes de la comunidad. Los participantes fueron evaluados por el MEEM y la Escala de Depresión Geriátrica (EDG). La puntuación del MEEM fue la variable dependiente. La edad, nivel educativo, sexo y puntuación en la EDG fueron las variables independientes. El análisis de regresión multivariada fue utilizado para determinar el modelo de mejor valor predictivo para los escores del MEEM. Se evaluaron 250 individuos entre 20 y 99 años, sin comprometimiento cognitivo. El nivel educativo, la edad y el sexo explicaron el 38% de la varianza total de la puntuación del MEEM (p <0,0001) y resultaron en la ecuación: MEEM=23,350+0,265(años de escolaridad)-0,042 (edad)+1,323 (sexo), en que mujer = 1 y hombre = 2. La puntuación del MEEM puede ser mejor explicada y predecible cuando se considera el nivel educativo, la edad y el sexo. Los resultados contribuyen para el conocimiento sobre las variables que influencian el score del MEEM, asà como proporciona una manera de considerar las variables en la puntuación de la prueba, proporcionando una mejor forma de triar a estos pacientes.The mini-mental state examination (MMSE) is a screening test used worldwide for identifying changes in the scope of cognition. Studies have shown the influence of education, age and sex in the MMSE score. However, in Brazil, the studies consider only one factor to score it. The aim of this study was to establish a prediction equation for the MMSE. An exploratory cross-sectional study was developed and trained researchers examined participants at the community. The volunteers were evaluated by the MMSE and also by the Geriatric Depression Scale (GDS). The MMSE score was the dependent variable. Age, educational level, sex, and GDS score were the independent variables. Multivariate regression analysis was used to determine the model of best prediction value for MMSE scores. A total of 250 participants aged 20-99 years, without cognitive impairment, were assessed. The educational level, age, and sex explained 38% of the total variance of the MMSE score (p<0.0001) and resulted in the following equation: MMSE=23.350+0.265(years of schooling)- 0.042(age)+1.323(sex), in which female=1 and male=2. The MMSE scores can be better explained and predicted when educational level, age, and sex are considered. These results enhance the knowledge regarding the variables that influence the MMSE score, as well as provide a way to consider all of them in the test score, providing a better screening of these patients
Breathing pattern in parkinson’s disease patients and healthy elderly subjects
Objective: To characteristic different components of breathing pattern in Parkinson’s Disease patients (PD) and healthy elderly subjects. Method: We studied 10 patients with PD’s severity III-IV by Hoehn and Yahr and 10 healthy elderly. The following respiratory variables analysed were: tidal volume, respiratory frequency, minute ventilation, inspiratory duty cycle, mean inspiratory flow, rib cage and abdomen contribution to tidal volume, using a calibrated respiratory inductive plethysmography. Statistical analysis was made using Student‘s t test for independents groups. Results: Parkinson’s Disease patients had tidal volume and mean inspiratory flow (p=0,01 and p=0,03 respectively) significantly lower, respiratory frequency significantly higher (p=0,03), resulting in a minute ventilation significantly lower (p=0,02) compared to elderly subjects. There was no significant difference in rib cage or abdomen contribution between the groups. Conclusion: These results showed that there are important changes in breathing pattern components of Parkinson’s Disease patients.Objetivo: Caracterizar diferentes componentes do padrão respiratório em pacientes portadores da Doença de Parkinson (DP) e em idosos assintomáticos. Método: Foram estudados 10 pacientes com DP com grau de acometimento III-IV segundo a escala de Hoehn e Yahr e 10 idosos assintomáticos. Variáveis respiratórias analisadas: volume corrente, freqüência respiratória, ventilação minuto, porcentagem do tempo inspiratório, fluxo inspiratório médio, contribuição da caixa torácica e do abdômen para o volume corrente, através da pletismografia respiratória por indutância calibrada. A análise estatÃstica foi feita através do teste t de Student para grupos independentes. Resultados: Os pacientes com DP apresentaram volume corrente e fluxo inspiratório médio menores (p=0,01 e p=0,03 respectivamente), uma freqüência respiratória maior (p=0,03), resultando numa ventilação minuto significativamente menor (p=0,02) comparados aos idosos assintomáticos. Não houve diferença significativa em relação à contribuição da caixa torácica e do abdômen entre os dois grupos. Conclusão: Estes resultados apontaram alterações importantes em diferentes componentes do padrão respiratório em pacientes portadores da DP
Capacidade funcional de indivÃduos com insuficiência cardÃaca avaliada pelo teste de esforço cardiopulmonar e classificação da New York Heart Association
O objetivo deste estudo foi avaliar a capacidade discriminativa da classificação da New York Heart Association (NYHA) em indivÃduos com insuficiência cardÃaca (IC) classes II e III por meio de variáveis do teste de esforço cardiopulmonar (TECP). Participaram do estudo 17 pessoas com IC classe II (44,47±10,11 anos; fração de ejeção ventricular 32,11±10,37%) e 15 classe III (46,73±8,74 anos; fração de ejeção ventricular 30,46±10,23%) da NYHA que realizaram TECP máximo em esteira ergométrica. De acordo com a distribuição dos dados, houve correlação de Pearson ou Spearman e, para comparação entre classes, utilizou-se o teste t de Student. Foram encontradas correlações significativas (pThe purpose of this study was to evaluate the capacity of the New York Heart Association (NYHA) classification to discriminate heart failure (HF) individuals classes II and III using cardiopulmonary exercise test (CPET) variables. Seventeen patients class II (age 44.47±10.11 years; ejection fraction 32.11±10.37%) and 15 class III (age 46.73±8.74 years; ejection fraction 30.46±10.23%) of NYHA participated in this study. They did a maximal CPET in a treadmill ergometer. According to the distribution of data, correlation of Pearson or Spearman was performed and, to compare the functional classes of NYHA, the Student's t-test was used. Significant correlations (