7,962 research outputs found
The rf control and detection system for PACO the parametric converter detector
In this technical note the rf control and detection system for a detector of
small harmonic displacements based on two coupled microwave cavities (PACO) is
presented. The basic idea underlying this detector is the principle of
parametric power conversion between two resonant modes of the system,
stimulated by the (small) harmonic modulation of one system parameter. In this
experiment we change the cavity length applying an harmonic voltage to a
piezo-electric crystal. The system can achieve a great sensitivity to small
harmonic displacements and can be an interesting candidate for the detection of
small, mechanically coupled, interactions (e.g. high frequency gravitational
waves).Comment: 13 pages, 4 postscript figure
Sub-millimeter nuclear medical imaging with high sensitivity in positron emission tomography using beta-gamma coincidences
We present a nuclear medical imaging technique, employing triple-gamma
trajectory intersections from beta^+ - gamma coincidences, able to reach
sub-millimeter spatial resolution in 3 dimensions with a reduced requirement of
reconstructed intersections per voxel compared to a conventional PET
reconstruction analysis. This '-PET' technique draws on specific beta^+
- decaying isotopes, simultaneously emitting an additional photon. Exploiting
the triple coincidence between the positron annihilation and the third photon,
it is possible to separate the reconstructed 'true' events from background. In
order to characterize this technique, Monte-Carlo simulations and image
reconstructions have been performed. The achievable spatial resolution has been
found to reach ca. 0.4 mm (FWHM) in each direction for the visualization of a
22Na point source. Only 40 intersections are sufficient for a reliable
sub-millimeter image reconstruction of a point source embedded in a scattering
volume of water inside a voxel volume of about 1 mm^3 ('high-resolution mode').
Moreover, starting with an injected activity of 400 MBq for ^76Br, the same
number of only about 40 reconstructed intersections are needed in case of a
larger voxel volume of 2 x 2 x 3~mm^3 ('high-sensitivity mode'). Requiring such
a low number of reconstructed events significantly reduces the required
acquisition time for image reconstruction (in the above case to about 140 s)
and thus may open up the perspective for a quasi real-time imaging.Comment: 17 pages, 5 figutes, 3 table
Parametric gravity wave detector
Since 1978 superconducting coupled cavities have been proposed as a sensitive
detector of gravitational waves. The interaction of the gravitational wave with
the cavity walls, and the esulting motion, induces the transition of some
energy from an initially excited cavity mode to an empty one. The energy
transfer is maximum when the frequency of the wave is equal to the frequency
difference of the two cavity modes. In 1984 Reece, Reiner and Melissinos built
a detector of the type proposed, and used it as a transducer of harmonic
mechanical motion, achieving a sensitivity to fractional deformations of the
order dx/x ~ 10^(-18). In this paper the working principles of the detector are
discussed and the last experimental results summarized. New ideas for the
development of a realistic gravitational waves detector are considered; the
outline of a possible detector design and its expected sensitivity are also
shown.Comment: 9 pages, 6 figures. Talk given at the Workshop on Electromagnetic
Probes of Fundamentals Physics, Erice (Italy), October 200
A detector of gravitational waves based on coupled microwave cavities
Since 1978 superconducting coupled cavities have been proposed as sensitive
detector of gravitational waves. The interaction of the gravitational wave with
the cavity walls, and the resulting motion, induces the transition of some
electromagnetic energy from an initially excited cavity mode to an empty one.
The energy transfer is maximum when the frequency of the wave is equal to the
frequency difference of the two cavity modes. In this paper the basic
principles of the detector are discussed. The interaction of a gravitational
wave with the cavity walls is studied in the proper reference frame of the
detector, and the coupling between two electromagnetic normal modes induced by
the wall motion is analyzed in detail. Noise sources are also considered; in
particular the noise coming from the brownian motion of the cavity walls is
analyzed. Some ideas for the developement of a realistic detector of
gravitational waves are discussed; the outline of a possible detector design
and its expected sensitivity are also shown.Comment: 29 pages, 12 eps figures. Typeset by REVTe
A detector of small harmonic displacements based on two coupled microwave cavities
The design and test of a detector of small harmonic displacements is
presented. The detector is based on the principle of the parametric conversion
of power between the resonant modes of two superconducting coupled microwave
cavities. The work is based on the original ideas of Bernard, Pegoraro, Picasso
and Radicati, who, in 1978, suggested that superconducting coupled cavities
could be used as sensitive detectors of gravitational waves, and on the work of
Reece, Reiner and Melissinos, who, {in 1984}, built a detector of this kind.
They showed that an harmonic modulation of the cavity length l produced an
energy transfer between two modes of the cavity, provided that the frequency of
the modulation was equal to the frequency difference of the two modes. They
achieved a sensitivity to fractional deformations of dl/l~10^{-17} Hz^{-1/2}.
We repeated the Reece, Reiner and Melissinos experiment, and with an improved
experimental configuration and better cavity quality, increased the sensitivity
to dl/l~10^{-20} Hz^{-1/2}. In this paper the basic principles of the device
are discussed and the experimental technique is explained in detail. Possible
future developments, aiming at gravitational waves detection, are also
outlined.Comment: 28 pages, 12 eps figures, ReVteX. \tightenlines command added to
reduce number of pages. The following article has been accepted by Review of
Scientific Instruments. After it is published, it will be found at
http://link.aip.org/link/?rs
Secondary zoospores in the algal endoparasite Maullinia ectocarpii (Plasmodiophorea).
The present paper deals with the ultrastructure of zoospores produced by the plasmodiophorid Maullinia ectocarpii , living in the marine algal host Ectocarpus siliculosus. The zoospores described here are very similar to secondary zoospores of Polymyxa graminis and Phagomyxa sp. (the latter an algal endopara- site, also). Our results indicate that M. ectocarpii produces two types of plasmodia, and suggest that is a species with a complete life cycle, as it is known for all the Plasmodiophormycota that have been studied. Sporogenic and sporangial plasmodia produce, respectively, primary zoospores with parallel flagella within thick walled resting sporangia, and secondary zoospores with opposite flagella within thin walled sporangia.Fil: Parodi, Elisa Rosalia. Consejo Nacional de Investigaciones CientĂficas y TĂ©cnicas; Argentina. Universidad Nacional del Sur; ArgentinaFil: Caceres, Eduardo Jorge. Universidad Nacional del Sur. Departamento de BiologĂa, BioquĂmica y Farmacia. Laboratorio de FicologĂa y MicologĂa; ArgentinaFil: Westermeier, Renato. Universidad Austral de Chile; ChileFil: Muller, Dieter G.. Universität Konstanz; Alemani
2000 CKM-Triangle Analysis A Critical Review with Updated Experimental Inputs and Theoretical Parameters
Within the Standard Model, a review of the current determination of the sides
and angles of the CKM unitarity triangle is presented, using experimental
constraints from the measurements of |\epsilon_K|, |V_{ub}/V_{cb}|, \Delta m_d
and from the limit on \Delta m_s, available in September 2000. Results from the
experimental search for {B}^0_s-\bar{B}^0_s oscillations are introduced in the
present analysis using the likelihood. Special attention is devoted to the
determination of the theoretical uncertainties. The purpose of the analysis is
to infer regions where the parameters of interest lie with given probabilities.
The BaBar "95 %, C.L. scanning" method is also commented.Comment: 44 pages (revised version
- …