13 research outputs found

    Glasgow Coma Scale and FOUR Score in Predicting the Mortality of Trauma Patients; a Diagnostic Accuracy Study

    Get PDF
    Introduction: Many scoring models have been proposed for evaluating level of consciousness in trauma patients. The aim of this study is to compare Glasgow coma scale (GCS) and Full Outline of UnResponsiveness (FOUR) score in predicting the mortality of trauma patients.Methods: In this diagnostic accuracy study trauma patients hospitalized in intensive care unit (ICU) of 2 educational hospitals were evaluated. GCS and FOUR score of each patient were simultaneously calculated on admission as well as 6, 12 and 24 hours after that. The predictive values of the two scores and their area under the receiver operating characteristics (ROC) curve were compared.Results: 90 patients were included in the present study (mean age 39.4±17.3; 74.4% male). Comparing the area under the ROC curve of GCS and FOUR score showed that these values were not different at any of the evaluated times: on admission (p=0.68), and 6 hours (p=0.13), 12 hours (p=0.18), and 24 hours (p=0.20) after that.Conclusion: The results of our study showed that, GCS and FOUR score have the same value in predicting the mortality of trauma patients. Both tools had high predictive power in predicting the outcome at the time of discharge

    Ebola Hemorrhagic Fever as a Public Health Emergency of International Concern; a Review Article

    Get PDF
    Ebola hemorrhagic fever (EHF) was first reported in 1976 with two concurrent outbreaks of acute viral hemorrhagic fever centered in Yambuku (near the Ebola River), Democratic Republic of Congo, and also in Nzara, Sudan. The current outbreak of the Ebola Virus was started by reporting the first case in March 2014 in the forest regions of southeastern Guinea. Due to raising infection rates of over 13,000% within a 6-month period, now is considered as a global public health emergency and in August 8, 2014 the World Health Organization (WHO) has declared the epidemic to be a Public Health Emergency of International Concern. With more than 5000 involved cases and also nearly 3000 deaths, this event has turned to the largest and most dangerous Ebola virus outbreak in all around the world. Based on above mentioned, the present article aimed to review the virologic characteristics, transmission, clinical manifestation, diagnosis, treatment, and prevention of Ebola virus disease

    Screening Performance Characteristic of Ultrasonography and Radiography in Detection of Pleural Effusion; a Meta-Analysis

    Get PDF
    Introduction: The role of ultrasonography in detection of pleural effusion has long been a subject of interest but controversial results have been reported. Accordingly, this study aims to conduct a systematic review of the available literature on diagnostic value of ultrasonography and radiography in detection of pleural effusion through a meta-analytic approach. Methods: An extended search was done in databases of Medline, EMBASE, ISI Web of Knowledge, Scopus, Cochrane Library, and ProQuest. Two reviewers independently extracted the data and assessed the quality of the articles. Meta-analysis was performed using a mixed-effects binary regression model. Finally, subgroup analysis was carried out in order to find the sources of heterogeneity between the included studies. Results: 12 studies were included in this meta-analysis (1554 subjects, 58.6% male). Pooled sensitivity of ultrasonography in detection of pleural effusion was 0.94 (95% CI: 0.88-0.97; I2= 84.23, p<0.001) and its pooled specificity was calculated to be 0.98 (95% CI: 0.92-1.0; I2= 88.65, p<0.001), while sensitivity and specificity of chest radiography were 0.51 (95% CI: 0.33-0.68; I2= 91.76, p<0.001) and 0.91 (95% CI: 0.68-0.98; I2= 92.86, p<0.001), respectively. Sensitivity of ultrasonography was found to be higher when the procedure was carried out by an intensivist or a radiologist using 5-10 MHz transducers. Conclusion: Chest ultrasonography, as a screening tool, has a higher diagnostic accuracy in identification of plural effusion compared to radiography. The sensitivity of this imaging modality was found to be higher when performed by a radiologist or an intensivist and using 5-10MHz probes

    Diagnostic Accuracy of Ultrasonography and Radiography in Detection of Pulmonary Contusion; a Systematic Review and Meta-Analysis

    Get PDF
    Introduction: Ultrasonography is currently being used as one of the diagnostic modalities in various medical emergencies for screening of trauma patients. The diagnostic value of this modality in detection of traumatic chest injuries has been evaluated by several studies but its diagnostic accuracy in diagnosis of pulmonary contusion is a matter of discussion. Therefore, the present study aimed to determine the diagnostic accuracy of ultrasonography and radiography in detection of pulmonary contusion through a systematic review and meta-analysis. Methods: An extended systematic search was performed by two reviewers in databases of Medline, EMBASE, ISI Web of Knowledge, Scopus, Cochrane Library, and ProQuest. They extracted the data and assessed the quality of the studies. After summarization of data into true positive, false positive, true negative, and false negative meta-analysis was carried out via a mixed-effects binary regression model. Further subgroup analysis was performed due to a significant heterogeneity between the studies. Results: 12 studies were included in this meta-analysis (1681 chest trauma patients, 76% male). Pooled sensitivity of ultrasonography in detection of pulmonary contusion was 0.92 (95% CI: 0.81-0.96; I2= 95.81, p<0.001) and its pooled specificity was calculated to be 0.89 (95% CI: 0.85-0.93; I2 = 67.29, p<0.001) while these figures for chest radiography were 0.44 (95% CI: 0.32-0.58; I2= 87.52, p<0.001) and 0.98 (95% CI: 0.88-1.0; I2= 95.22, p<0.001), respectively. Subgroup analysis showed that the sources of heterogeneity between the studies were sampling method, operator, frequency of the transducer, and sample size. Conclusion: Ultrasonography was found to be a better screening tool in detection of pulmonary contusion. Moreover, an ultrasonography performed by a radiologist / intensivist with 1-5MHz probe has a higher diagnostic value in identifying pulmonary contusions

    Application of Ultrasonography and Radiography in Detection of Hemothorax: a Systematic Review and Meta-Analysis

    Get PDF
    Introduction: Hemothorax is one of the most prevalent injuries caused by thoracic traumas. Early detection and treatment of this injury is of utmost importance in prognosis of the patient, but there are still controversial debates on the diagnostic value of imaging techniques in detection of hemothorax. Therefore, the present study aimed to evaluate the diagnostic value of chest ultrasonography and radiography in detection of hemothorax through a systematic review and meta-analysis. Methods: Two independent reviewers performed an extended systematic search in databases of Medline, EMBASE, ISI Web of Knowledge, Scopus, Cochrane Library, and ProQuest. Data were extract and quality of the relevant studies were assessed. The number of true positive, false positive, true negative and false negative cases were extracted and screening performance characteristics of two imaging techniques were calculated using a mixed-effects binary regression model. Results: Data from 12 studies were extracted and included in the meta-analysis (7361 patients, 77.1% male). Pooled sensitivity and specificity of ultrasonography in detection of hemothorax were 0.67 (95% CI: 0.41-0.86; I2= 68.38, p<0.001) and 0.99 (95% CI: 0.95-1.0; I2= 88.16, p<0.001), respectively. These measures for radiography were 0.54 (95% CI: 0.33-0.75; I2= 92.85, p<0.001) and 0.99 (95% CI: 0.94-1.0; I2= 99.22, p<0.001), respectively. Subgroup analysis found operator of the ultrasonography device, frequency of the transducer and sample size to be important sources of heterogeneity of included studies. Conclusion: The results of this study showed that although the sensitivity of ultrasonography in detection of hemothorax is relatively higher than radiography, but it is still at a moderate level (0.67%). The specificity of both imaging modalities were found to be at an excellent level in this regard. The screening characteristics of ultrasonography was found to be influenced of the operator and frequency of transducer

    The efficacy of Schwann cell transplantation on motor function recovery after spinal cord injuries in animal models: A systematic review and meta-analysis

    Get PDF
    Aim: This article aimed to assess the efficacy of Schwann cell transplantation on motor function recovery in animal model of spinal cord injuries via meta-analysis. Methods: An extended search was carried out in the electronic databases of Medline (via PubMed), EMBASE (via OvidSP), CENTRAL, SCOPUS, Web of Science (BIOSIS), and ProQuest. Finally, 41 eligible studies conducted on 1046 animals including 517 control animals and 529 transplanted animals were included in the meta-analysis. Pooled standardized mean difference (SMD) and odds ratio (OR) with 95% confidence interval (95% CI) were reported. Results: The findings showed that treatment with Schwann cells leads to a modest motor function recovery after spinal cord injury (SMD = 0.85; 95% CI: 0.63–1.07; p < 0.001). Transplantation of these cells in acute phase of the injury (immediately after the injury) (OR = 4.30; 95% CI: 1.53–12.05; p = 0.007), application of mesenchymal/skin-derived precursors (OR = 2.34; 95% CI: 1.28–4.29; p = 0.008), and cells with human sources are associated with an increase in efficacy of Schwann cells (OR = 10.96; 95% CI: 1.49–80.77; p = 0.02). Finally, it seems thatthe efficacy of Schwann cells in mice is significantly lower than rats (OR = 0.03; 95% CI: 0.003–0.41; p = 0.009). Conclusion: Transplantation of Schwann cells can moderately improve motor function recovery. It seems that inter-species differences might exist regarding the efficacy of this cells. Therefore, this should be taken into account when using Schwann cells in clinical trials regarding spinal cord injuries

    Early versus Late Decompression for Traumatic Spinal Cord Injuries; a Systematic Review and Meta-analysis

    Get PDF
    Introduction: Despite the vast number of surveys, no consensus has been reached on the optimum timing of spinal decompression surgery. This systematic review and meta-analysis aimed to compare the effects of early and late spinal decompression surgery on neurologic improvement and post-surgical complications in patients with traumatic spinal cord injuries.Methods: Two independent reviewers carried out an extended search in electronic databases. Data of neurological outcome and post-surgery complication were extracted. Finally, pooled relative risk (RR) with a 95% confidence interval (CI) was reported for comparing of efficacy of early and late surgical decompression.Results: Eventually 22 studies were included. The pooled RR was 0.77 (95% CI: 0.68-0.89) for at least one grade neurological improvement, and 0.84 (95% CI: 0.77-0.92) for at least two grade improvement. Pooled RR for surgical decompression performed within 12 hours after the injury was 0.26 (95% CI: 0.13-0.52; p&lt;0.001), while it was 0.75 (95% CI: 0.63-0.90; p=0.002) when the procedure was performed within 24 hours, and 0.93 (95% CI: 0.76-1.14; p=0.48) when it was carried out in the first 72 hours after the injury. Surgical decompression performed within 24 hours after injury was found to be associated with significantly lower rates of post-surgical complications (RR=0.77; 95% CI: 0.68-0.86; p&lt;0.001).Conclusion: The findings of this study indicate that early spinal decompression surgery can improve neurologic recovery and is associated with less post-surgical complications. The optimum efficacy is observed when the procedure is performed within 12 hours of the injury

    Comparison of Ultrasonography and Radiography in Detection of Thoracic Bone Fractures; a Systematic Review and Meta-Analysis

    Get PDF
    Introduction: The potential benefit of ultrasonography for detection of thoracic bone fractures has been proven in various surveys but no comprehensive conclusion has been drawn yet; therefore, the present study aimed to conduct a thorough meta-analytic systematic review on this subject. Methods: Two reviewers independently carried out a comprehensive systematic search in Medline, EMBASE, ISI Web of Knowledge, Scopus, Cochrane Library, and ProQuest databases. Data were summarized as true positive, false positive, true negative and false negative and were analyzed via STATA 11.0 software using a mixed-effects binary regression model. Sources of heterogeneity were further assessed through subgroup analysis. Results: Data on 1667 patients (807 subjects with and 860 cases without thoracic fractures), whose age ranged from 0 to 92 years, were extracted from 17 surveys. Pooled sensitivity and specificity of ultrasonography in detection of thoracic bone fractures were 0.97 (95% CI: 0.90-0.99; I2= 88.88, p&lt;0.001) and 0.94 (95% CI: 0.86-0.97; I2= 71.97, p&lt;0.001), respectively. The same measures for chest radiography were found to be 0.77 (95% CI: 0.56-0.90; I2= 97.76, p&lt;0.001) and 1.0 (95% CI: 0.91-1.00; I2= 97.24, p&lt;0.001), respectively. The sensitivity of ultrasonography was higher in detection of rib fractures, compared to fractures of sternum or clavicle (97% vs. 91%). Moreover, the sensitivity was found to be higher when the procedure was carried out by a radiologist in comparison to an emergency medicine specialist (96% vs. 90%). Conclusion: Base on the findings of the present meta-analysis, screening performance characteristic of ultrasonography in detection of thoracic bone fractures was found to be higher than radiography. However, these characteristics were more prominent in detection of rib fractures and in cases where was performed by a radiologist

    Blood pressure percentiles by age and body mass index for adults

    Get PDF
    Since no comprehensive study has been conducted on blood pressure (BP) percentiles established upon nationally representative sample population of adults, the present study aimed to construct the blood pressure percentiles by age, sex and body mass index (BMI) of the subjects. Analyses were based on data collected in 2011 from 8,425 adults aged 25 to 69 years old. Data on demographic characteristics, anthropometric measurements, and blood pressure was recorded for each subject. Linear Regression analysis was used to assess the adjusted relationship of age-sex-specific standard deviation scores of BMI, height, and weight with blood pressure. Four separate models for systolic blood pressure (SBP) and diastolic blood pressure (DBP) of men and women were constructed for BP percentiles according to age and BMI. Blood pressure increased with the rise in BMI and weight, but showed a negative correlation with height. SBP and DBP rose steadily with increasing age, but the rise in SBP was greater than DBP. Overweight and obese population, seem to fall into the category of hypertensive. The findings of present study show that BP percentiles are steadily increased by age and BMI. In addition, most obese or overweight adults are hypertensive
    corecore