88 research outputs found

    Impact of storage conditions on profilometry of eroded dental hard tissue

    Get PDF
    The aim of the present study was to analyze in how far drying of eroded dentin and enamel surfaces influence the results of profilometrical determinations with a stylus profilometer. Each five dentin and enamel samples were eroded with HCl (pH 2.6, 2min). Surface profiles of the samples were recorded with a stylus profilometer in three series. In series 1, the samples were measured while stored in water and in series 2, under ambient conditions (21°C, 35% humidity). In series 3, samples were completely desiccated and then rewetted. Profilometry was conducted at various time intervals for a period of up to 181min (series 1 and 2) and 72h (series 3). Only the dentin samples were affected by the storage conditions. Stable profilometrical readings for the eroded dentin samples were only feasible when the specimens were stored in water during the complete period of the experiment, including the profilometrical measurement. Thus, for erosion experiments using profilometrical analysis with a stylus profilometer, it is advised to store and measure dentin samples under wet condition

    Randomized controlled pilot study comparing small buccal defects around dental implants treated with a subepithelial connective tissue graft or with guided bone regeneration

    Get PDF
    AIM To compare subepithelial connective tissue grafts (SCTG) versus guided bone regeneration (GBR) for the treatment of small peri-implant dehiscence defects in terms of profilometric (primary outcome), clinical, and patient-reported outcome measures (PROMs). METHODS Sixteen patients who presented with small buccal bone dehiscences (≀3 mm) following single implant placement were recruited. Following implant placement, buccal bone defect sites were randomly treated either with a SCTG or GBR. Six patients who lacked bone dehiscences after implant placement were assigned to a negative control. Transmucosal healing was applied in all patients. Patients were examined prior (T1) and after (T2) implant placement, at suture removal (T3), at implant impression (T5), at crown delivery (T6), and 12 (T7) months after crown delivery. Measurements included profilometric outcomes, marginal bone levels, buccal bone and soft tissue thickness, PROMs, and clinical parameters. All data were analyzed descriptively. RESULTS The median changes in buccal contour as assessed by profilometric measures between T1 and T5 showed a decrease of 1.84 mm for the SCTG group and 1.06 mm for the GBR group. Between T2 and T7, the median change in the buccal contour amounted to 0.45 mm for SCTG and -0.94 mm (=loss) for GBR. Patients' pain perception tended to be higher in SCTG than in GBR. All peri-implant soft tissue parameters showed healthy oral tissues and no clinically relevant differences between groups. CONCLUSION Within the limitations of this pilot study, treating small peri-implant dehiscence defects with a SCTG might be a viable alternative to GBR. The use of a SCTG tended to result in more stable profilometric outcomes and comparable clinical outcomes to GBR. However, patient-reported outcome measures tended to favor GBR

    Penetration of Sodium Hypochlorite Modified with Surfactants into Root Canal Dentin

    Get PDF
    Abstract The aim of this study was to evaluate the effect of concentration, exposure time and temperature of sodium hypochlorite (NaOCl) added with surfactants on its penetration into dentinal tubules. Sixty-five extracted human permanent maxillary anterior teeth with single canals were prepared by ProTaper SX hand-operated instruments. The teeth were then sectioned perpendicular to the long axis. The crowns and apical thirds of all the teeth were removed. The remaining roots were processed into 4-mm-long blocks and stained overnight in crystal violet. One hundred and thirty stained blocks were further split into halves and treated by nine different types of NaOCl-based solutions. Three solutions were added with surfactants (Hypoclean, H6, Chlor-Xtra) and the others were regular hypochlorites at increasing concentrations (1%, 2%, 4%, 5.25%, <6%, 6% NaOCl) from different brands. The dentin blocks were exposed to the solutions for 2, 5, and 20 min at 20 °C, 37 °C and 45 °C, respectively. The depth of NaOCl penetration was determined by bleaching of the stain and measured by light microscopy at 20&#61472;&#61620; and 40&#61620;. Statistical comparisons were made by using a generalized linear model with Bonferroni's post-hoc correction. The shortest penetration (81±6.6 &#956;m) was obtained after incubation in 1% NaOCl for 2 min at 20 °C; the highest penetration (376.3±3.8 &#956;m) was obtained with Chlor-Xtra for 20 min at 45 °C. Varying NaOCl concentration produced a minimal effect while temperature and exposure time had a significant direct relationship with NaOCl penetration into dentinal tubules, especially those with lowered surface tension. The exposure time and temperature of sodium hypochlorite as well as the addition of surfactants may influence the penetration depth of irrigants into dentinal tubules

    Truth or precision? Some reflections on the economists’ failure to predict the financial crisis

    Get PDF
    The failure of professional economic forecasters to predict the financial crises has led many to question the credibility of modern economics as a reliable foundation for economic policy. If economists were unable to foresee so big a crisis, how can they be trusted to cure or prevent it? Several accounts of this failure exist. The paper offers a tentative answer based on the lessons that may be drawn from the wisdom of a short list of past and present economists: Hayek, Neville Keynes, Mankiw, Tinbergen, Maynard Keynes and Lucas. The glue to keep such an odd bunch together is the distinction between truth and precision provided by science historian Ted Porter

    The effect of a manual instrumentation technique on five types of premolar root canal geometry assessed by microcomputed tomography and three-dimensional reconstruction

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Together with diagnosis and treatment planning, a good knowledge of the root canal system and its frequent variations is a necessity for successful root canal therapy. The selection of instrumentation techniques for variants in internal anatomy of teeth has significant effects on the shaping ability and cleaning effectiveness. The aim of this study was to reveal the differences made by including variations in the internal anatomy of premolars into the study protocol for investigation of a single instrumentation technique (hand ProTaper instruments) assessed by microcomputed tomography and three-dimensional reconstruction.</p> <p>Methods</p> <p>Five single-root premolars, whose root canal systems were classified into one of five types, were scanned with micro-CT before and after preparation with a hand ProTaper instrument. Instrumentation characteristics were measured quantitatively in 3-D using a customized application framework based on MeVisLab. Numeric values were obtained for canal surface area, volume, volume changes, percentage of untouched surface, dentin wall thickness, and the thickness of dentin removed. Preparation errors were also evaluated using a color-coded reconstruction.</p> <p>Results</p> <p>Canal volumes and surface areas were increased after instrumentation. Prepared canals of all five types were straightened, with transportation toward the inner aspects of S-shaped or multiple curves. However, a ledge was formed at the apical third curve of the type II canal system and a wide range in the percentage of unchanged canal surfaces (27.4-83.0%) was recorded. The dentin walls were more than 0.3 mm thick except in a 1 mm zone from the apical surface and the hazardous area of the type II canal system after preparation with an F3 instrument.</p> <p>Conclusions</p> <p>The 3-D color-coded images showed different morphological changes in the five types of root canal systems shaped with the same hand instrumentation technique. Premolars are among the most complex teeth for root canal treatment and instrumentation techniques for the root canal systems of premolars should be selected individually depending on the 3-D canal configuration of each tooth. Further study is needed to demonstrate the differences made by including variations in the internal anatomy of teeth into the study protocol of clinical RCT for identifying the best preparation technique.</p
    • 

    corecore