2,585 research outputs found

    Advanced radiation measurement techniques in diagnostic radiology and molecular imaging.

    Get PDF
    This paper reports some technological advances recently achieved in the fields of micro-CT and small animal PET instrumentation. It highlights a balance between image-quality improvement and dose reduction. Most of the recent accomplishments in these fields are due to the use of novel imaging sensors such as CMOS-based X-ray detectors and silicon photomultipliers (SiPM). Some of the research projects carried out at the University of Pisa for the development of such advanced radiation imaging technology are also described

    Long-time Behavior of a Two-layer Model of Baroclinic Quasi-geostrophic Turbulence

    Full text link
    We study a viscous two-layer quasi-geostrophic beta-plane model that is forced by imposition of a spatially uniform vertical shear in the eastward (zonal) component of the layer flows, or equivalently a spatially uniform north-south temperature gradient. We prove that the model is linearly unstable, but that non-linear solutions are bounded in time by a bound which is independent of the initial data and is determined only by the physical parameters of the model. We further prove, using arguments first presented in the study of the Kuramoto-Sivashinsky equation, the existence of an absorbing ball in appropriate function spaces, and in fact the existence of a compact finite-dimensional attractor, and provide upper bounds for the fractal and Hausdorff dimensions of the attractor. Finally, we show the existence of an inertial manifold for the dynamical system generated by the model's solution operator. Our results provide rigorous justification for observations made by Panetta based on long-time numerical integrations of the model equations

    Fast 3D-EM reconstruction using Planograms for stationary planar positron emission mammography camera

    Get PDF
    Summary At the University of Pisa we are building a PEM prototype, the YAP–PEM camera, consisting of two opposite 6×6×3 cm 3 detector heads of 30×30 YAP:Ce finger crystals, 2×2×30 mm 3 each. The camera will be equipped with breast compressors. The acquisition will be stationary. Compared with a whole body PET scanner, a planar Positron Emission Mammography (PEM) camera allows a better, easier and more flexible positioning around the breast in the vicinity of the tumor: this increases the sensitivity and solid angle coverage, and reduces cost. To avoid software rejection of data during the reconstruction, resulting in a reduced sensitivity, we adopted a 3D-EM reconstruction which uses all of the collected Lines Of Response (LORs). This skips the PSF distortion given by data rebinning procedures and/or Fourier methods. The traditional 3D-EM reconstruction requires several times the computation of the LOR-voxel correlation matrix, or probability matrix { p ij }; therefore is highly time-consuming . We use the sparse and symmetry properties of the matrix { p ij } to perform fast 3D-EM reconstruction. Geometrically, a 3D grid of cubic voxels (FOV) is crossed by several divergent 3D line sets (LORs). The symmetries occur when tracing different LORs produces the same p ij value. Parallel LORs of different sets cross the FOV in the same way, and the repetition of p ij values depends on the ratio between the tube and voxel sizes. By optimizing this ratio, the occurrence of symmetries is increased. We identify a nucleus of symmetry of LORs: for each set of symmetrical LORs we choose just one LOR to be put in the nucleus , while the others lie outside. All of the possible p ij values are obtainable by tracking only the LORs of this nucleus . The coordinates of the voxels of all of the other LORs are given by means of simple translation rules. Before making the reconstruction, we trace the LORs of the nucleus to find the intersecting voxels, whose p ij values are computed and stored with their voxel coordinates on a hard disk. Only the non-zero p ij are considered and their computation is performed just once. During the reconstruction, the stored values are loaded and are available in the random access memory for all of the operations of normalization, backprojection and projection: these are now performed rapidly, because the application of the translation rules is much faster than the probability computations. We tested the algorithm on Monte Carlo data fully simulating the typical YAP–PEM clinical condition. The adopted algorithm gives an excellent positioning capability for hot spots in the camera FOV. To use all of the possible skew LORs in the FOV avoids the software rejection of collected data. Reconstructed images indicate that a 5 mm diameter tumor of 37 kBq/cm 3 , in an active breast with a 10:1 Tissue to Background ratio (T/B), with a 10 min acquisition, for a head distance of 5 cm, can be detected by the YAP–PEM with a SNR of 8.7±1.0. The obtained SNR values depend linearly on the tumor volume. The algorithm allows one to discriminate between two hot sources of 5.0 mm diameter if they do not lie on the same axis. The YAP–PEM is now in the assembly stage

    TWO CASES OF NON-ALCOHOLIC WERNICKE ENCEPHALOPATHY SUCCESSFULLY TREATED BY THIAMINE REPLACEMENT: DIAGNOSTIC AND THERAPEUTIC CONSIDERATIONS

    Get PDF
    Wernicke\u2019s encephalopathy (WE) is an acute neurologi- cal disorder, due to a lack of thiamin (vitamin B1) which is observed mainly in alcoholic patients. Unfortunately, the syn- drome is underestimated in clinical practice and most often recognized only on autopsy, especially among non-alcoholics. The common clinical picture include mental status changes, ocular dysfunction, and gait ataxia. Treatment consists of timely thiamine replacement through intravenous infusion. We describe the case of two patients who developed a non-alcoholic WE post-surgical, regressed completely after intravenous infusion of thiamine. These cases suggest intere- sting diagnostic and therapeutic implications

    The unsolved challenges of space biospheres: a research agenda

    Get PDF

    3D enamel thickness in Neandertal and modern human permanent canines

    Get PDF
    Enamel thickness figures prominently in studies of human evolution, particularly for taxonomy, phylogeny, and paleodietary reconstruction. Attention has focused on molar teeth, through the use of advanced imaging technologies and novel protocols. Despite the important results achieved thus far, further work is needed to investigate all tooth classes. We apply a recent approach developed for anterior teeth to investigate the 3D enamel thickness of Neandertal and modern human (MH) canines. In terms of crown size, the values obtained for both upper and lower unworn/slightly worn canines are significantly greater in Neandertals than in Upper Paleolithic and recent MH. The 3D relative enamel thickness (RET) is significantly lower in Neandertals than in MH. Moreover, differences in 3D RET values between the two groups appear to decrease in worn canines beginning from wear stage 3, suggesting that both the pattern and the stage of wear may have important effects on the 3D RET value. Nevertheless, the 3D average enamel thickness (AET) does not differ between the two groups. In both groups, 3D AET and 3D RET indices are greater in upper canines than in lower canines, and overall the enamel is thicker on the occlusal half of the labial aspect of the crown, particularly in MH. By contrast, the few early modern humans investigated show the highest volumes of enamel while for all other components of 3D enamel, thickness this group holds an intermediate position between Neandertals and recent MH. Overall, our study supports the general findings that Neandertals have relatively thinner enamel than MH (as also observed in molars), indicating that unworn/slightly worn canines can be successfully used to discriminate between the two groups. Further studies, however, are needed to understand whether these differences are functionally related or are the result of pleiotropic or genetic drift effects

    Dispersive stabilization of the inverse cascade for the Kolmogorov flow

    Full text link
    It is shown by perturbation techniques and numerical simulations that the inverse cascade of kink-antikink annihilations, characteristic of the Kolmogorov flow in the slightly supercritical Reynolds number regime, is halted by the dispersive action of Rossby waves in the beta-plane approximation. For beta tending to zero, the largest excited scale is proportional to the logarithm of one over beta and differs strongly from what is predicted by standard dimensional phenomenology which ignores depletion of nonlinearity.Comment: 4 pages, LATEX, 3 figures. v3: revised version with minor correction

    Is it possible to make a diagnosis of raw, heated and baked egg allergy in children using cut-offs? A systematic review

    Get PDF
    The diagnosis of IgE-mediated egg allergy lies both on a compatible clinical history and on the results of skin prick tests (SPTs) and IgEs levels. Both tests have good sensitivity but low specificity. For this reason, oral food challenge (OFC) is the ultimate gold standard for the diagnosis. The aim of the present paper is to systematically review the literature in order to identify, analyze and synthesize the predictive value of SPT and specific IgEs both to egg white and main egg allergens and to review the cut-offs suggested in the literature
    • …
    corecore