1,570 research outputs found

    Some recent results in aerospace vehicle trajectory optimization techniques

    Get PDF
    Algorithms and computation techniques for solving trajectory optimization problem

    Nurses\u27 Alumnae Association Bulletin, April 1961

    Get PDF
    Alumnae Meetings 1960 Social Committee Clara Melville Scholarship Fund Bulletin Committee Private Duty Nurse\u27s Section Report of the School of Nursing and Nursing Service Staff Nurses Association Student Activities Personal Items of Interest Expansion of Jefferson Artificial Kidney Unit Medical Work in the Congo Marriages New Arrivals Necrology Annual Giving Fun

    Nurses\u27 Alumnae Association Bulletin, April 1962

    Get PDF
    Staff Nurses Association Alumnae Meetings 1961 Social Committee Clara Melville Scholarship Fund Ways and Means Report Cook Book Report Bulletin Committee Private Duty Nurse\u27s Section Hospital Report and Nursing Service Federal Nursing Service Practice of Nursing Report of Student Council Activities Medical Work in Ghan

    Pharmacokinetics of carprofen and firocoxib for medication control in racing greyhounds

    Get PDF
    Animals used in sport should be treated as required to ensure animal welfare but any such use of medication should also be controlled to ensure integrity. Pharmacokinetic studies on groups of six greyhounds were performed to measure plasma and urine levels of carprofen and firocoxib to inform medication control advice. Using the standard methodology for medication control the Irrelevant Plasma Concentration was determined as 20 ng/mL and 2 ng/mL for carprofen and firocoxib respectively. The Irrelevant Urine Concentration was also determined as 0.3 ng/ml and 2 ng/mL for carprofen and firocoxib respectively. These Irrelevant Plasma and Urine Concentrations will allo

    Smoke-Free Policy in Vermont Public Housing Authorities

    Get PDF
    Introduction. Millions of adults and children living in public housing face exposure to second hand smoke from adjacent apartments. These tenants are less able to escape smoke exposure by moving, and Housing Authorities are beginning to implement smoke-free policies. We assessed the status of smoke-free policy in Vermont public housing, and explored the experience of tenants and managers in Burlington who recently implemented such a policy.https://scholarworks.uvm.edu/comphp_gallery/1080/thumbnail.jp

    Preliminary performance measurements of bolometers for the Planck high-frequency instrument

    Get PDF
    We report on the characterization of bolometers fabricated at the Jet Propulsion Laboratory for the High Frequency Instrument (HFI) of the joint ESA/NASA Herschel/Planck mission to be launched in 2007. The HFI is a multicolor focal plane which consists of 48 bolometers operated at 100mK. Each bolometer is mounted to a feedhorn-filter assembly which defines one of six frequency bands centered between 100-857GHz. Four detectors in each of six bands are coupled to both linear polarizations and thus measure the total intensity. In addition, eight detectors in each of 3 bands (143, 217, and 353GHz) couple only to a single linear polarization and thus provide measurements of the Stokes parameters, Q and U, as well the total intensity. The detectors are required to achieve a Noise Equivalent Power (NEP) at or below the background limit ∼ 10^(-17)W/√Hz for the telescope and time constants of a few ms, short enough to resolve point sources as the 5 to 9 arc-minute beams move across the sky in great circles at 1 rpm. The bolometers are tested at 100mK in a commercial dilution refrigerator with a custom built thermal control system to regulate the heat sink with precision < 100nK/√Hz. The 100mK tests include dark electrical characterization of the load curves, optical and electrical measurement of the thermal time constants and measurement of the noise spectral density from 0.01 to 10Hz for up to 24 bolometers simultaneously

    Keck Interferometer Nuller Data Reduction and On-Sky Performance

    Get PDF
    We describe the Keck Interferometer nuller theory of operation, data reduction, and on-sky performance, particularly as it applies to the nuller exozodiacal dust key science program that was carried out between 2008 February and 2009 January. We review the nuller implementation, including the detailed phasor processing involved in implementing the null-peak mode used for science data and the sequencing used for science observing. We then describe the Level 1 reduction to convert the instrument telemetry streams to raw null leakages, and the Level 2 reduction to provide calibrated null leakages. The Level 1 reduction uses conservative, primarily linear processing, implemented consistently for science and calibrator stars. The Level 2 processing is more flexible, and uses diameters for the calibrator stars measured contemporaneously with the interferometer’s K-band cophasing system in order to provide the requisite accuracy. Using the key science data set of 462 total scans, we assess the instrument performance for sensitivity and systematic error. At 2.0 Jy we achieve a photometrically-limited null leakage uncertainty of 0.25% rms per 10 minutes of integration time in our broadband channel. From analysis of the Level 2 reductions, we estimate a systematic noise floor for bright stars of ~0.2% rms null leakage uncertainty per observing cluster in the broadband channel. A similar analysis is performed for the narrowband channels. We also provide additional information needed for science reduction, including details on the instrument beam pattern and the basic astrophysical response of the system, and references to the data reduction and modeling tools

    The dusty AGB star RS CrB: first mid-infrared interferometric observations with the Keck Telescopes

    Full text link
    We report interferometric observations of the semi-regular variable star RS CrB, a red giant with strong silicate emission features. The data were among the first long baseline mid-infrared stellar fringes obtained between the Keck telescopes, using parts of the new nulling beam combiner. The light was dispersed by a low-resolution spectrometer, allowing simultaneous measurement of the source visibility and intensity spectra from 8 to 12 microns. The interferometric observations allow a non-ambiguous determination of the dust shell spatial scale and relative flux contribution. Using a simple spherically-symmetric model, in which a geometrically thin shell surrounds the stellar photosphere, we find that ~30% to ~70% of the overall mid-infrared flux - depending on the wavelength - originates from 7-8 stellar radii. The derived shell opacity profile shows a broad peak around 11 microns (tau ~ 0.06), characteristic of Mg-rich silicate dust particles.Comment: Accepted for publication in ApJ Letter

    Ethical and compliance-competence evaluation: a key element of sound corporate governance

    Get PDF
    Motivated by the ongoing post-Enron refocusing on corporate governance and the shift by the Financial Services Authority (FSA) in the UK to promoting compliance- competence within the financial services sector, this paper demonstrates how template analysis can be used as a tool for evaluating compliance-competence. Focusing on the ethical dimension of compliance-competence, we illustrate how this can be subjectively appraised. We propose that this evaluation technique could be utilised as a starting point in informing senior management of corporate governance issues and be used to monitor and demonstrate key compliance and ethical aspects of an institution to external stakeholders and regulators
    • …
    corecore