20 research outputs found
Overview of recent TJ-II stellarator results
The main results obtained in the TJ-II stellarator in the last two years are reported. The most important topics investigated have been modelling and validation of impurity transport, validation of gyrokinetic simulations, turbulence characterisation, effect of magnetic configuration on transport, fuelling with pellet injection, fast particles and liquid metal plasma facing components. As regards impurity transport research, a number of working lines exploring several recently discovered effects have been developed: the effect of tangential drifts on stellarator neoclassical transport, the impurity flux driven by electric fields tangent to magnetic surfaces and attempts of experimental validation with Doppler reflectometry of the variation of the radial electric field on the flux surface. Concerning gyrokinetic simulations, two validation activities have been performed, the comparison with measurements of zonal flow relaxation in pellet-induced fast transients and the comparison with experimental poloidal variation of fluctuations amplitude. The impact of radial electric fields on turbulence spreading in the edge and scrape-off layer has been also experimentally characterized using a 2D Langmuir probe array. Another remarkable piece of work has been the investigation of the radial propagation of small temperature perturbations using transfer entropy. Research on the physics and modelling of plasma core fuelling with pellet and tracer-encapsulated solid-pellet injection has produced also relevant results. Neutral beam injection driven Alfvénic activity and its possible control by electron cyclotron current drive has been examined as well in TJ-II. Finally, recent results on alternative plasma facing components based on liquid metals are also presentedThis work has been carried out within the framework of the EUROfusion Consortium and has received funding from the Euratom research and training programme 2014–2018 under Grant Agreement No. 633053. It has been partially funded by the Ministerio de Ciencia, Inovación y Universidades of Spain under projects ENE2013-48109-P, ENE2015-70142-P and FIS2017-88892-P. It has also received funds from the Spanish Government via mobility grant PRX17/00425. The authors thankfully acknowledge the computer resources at MareNostrum and the technical support provided by the Barcelona S.C. It has been supported as well by The Science and Technology Center in Ukraine (STCU), Project P-507F
Towards a new image processing system at Wendelstein 7-X: From spatial calibration to characterization of thermal events
Wendelstein 7-X (W7-X) is the most advanced fusion experiment in the stellarator line and is aimed at proving that the stellarator concept is suitable for a fusion reactor. One of the most important issues for fusion reactors is the monitoring of plasma facing components when exposed to very high heat loads, through the use of visible and infrared (IR) cameras. In this paper, a new image processing system for the analysis of the strike lines on the inboard limiters from the first W7-X experimental campaign is presented. This system builds a model of the IR cameras through the use of spatial calibration techniques, helping to characterize the strike lines by using the information given by real spatial coordinates of each pixel. The characterization of the strike lines is made in terms of position, size, and shape, after projecting the camera image in a 2D grid which tries to preserve the curvilinear surface distances between points. The description of the strike-line shape is made by means of the Fourier Descriptors
Forward modeling of collective Thomson scattering for Wendelstein 7-X plasmas: Electrostatic approximation
In this paper, we present a method for numerical computation of collective Thomson scattering (CTS). We developed a forward model, eCTS, in the electrostatic approximation and benchmarked it against a full electromagnetic model. Differences between the electrostatic and the electromagnetic models are discussed. The sensitivity of the results to the ion temperature and the plasma composition is demonstrated. We integrated the model into the Bayesian data analysis framework Minerva and used it for the analysis of noisy synthetic data sets produced by a full electromagnetic model. It is shown that eCTS can be used for the inference of the bulk ion temperature. The model has been used to infer the bulk ion temperature from the first CTS measurements on Wendelstein 7-X
Confinement studies in the TJ-II stellarator
ECR (electron cyclotron resonance) heated plasmas have been studied in the low magnetic shear TJ-II stellarator (R = 1.5 m, a < 0.22 m, B = 1 T, f = 53.2 GHz, P-ECRH = 300 kW, power density = 1-25 W cm(-3)). Recent experiments have explored the flexibility of the TJ-II across a wide range of plasma volumes with different rotational transforms and rational surface densities. In this paper, the main results of this campaign are presented and, in particular, the influence of iota and rational surfaces on plasma profiles is discussed
Prevention and Treatment of Biopsy-Related Complications
Transrectal biopsy of the prostate is necessary in the diagnosis of prostate cancer (PC). Though generally considered safe, patients encounter minor complications such as bleeding and urinary symptoms, and uncommonly, serious infections that may require antibiotic therapy, visits to the emergency room (ER) or hospital admission, causing morbidity and rarely even mortality. It is concerning that infections are on the rise due to resistant bacteria. Urologists will have to be aware of bacterial susceptibility studies to reduce such complications. This review focuses on prostate biopsy and its complications, and measures to reduce these complications in our practice
First plasmas in the TJ-II flexible Heliac
The first experimental campaign of the TJ-II stellarator has been conducted using electron cyclotron resonance heating (f = 53.2 GHz, P-ECRH approximate to 250 kW) with a pulse length of Delta t approximate to (80-200) ms. The flexibility of the device has been used to study five different configurations varying plasma volume and rotational transform. In this paper, the main results of this campaign are presented and, in particular, the influence of plasma-wall interaction phenomena on TJ-II confinement is briefly discussed