2,792 research outputs found

    Effectiveness of delayed-release dimethyl fumarate on patient-reported outcomes and clinical measures in patients with relapsing-remitting multiple sclerosis in a real-world clinical setting: PROTEC.

    Get PDF
    Ensaio clínico PROTEC, Protocolo nº 109MS408Abstract BACKGROUND: Patient-reported outcomes (PRO) and clinical outcomes give a broad assessment of relapsing-remitting multiple sclerosis (RRMS) disease. OBJECTIVE: The aim is to evaluate the effectiveness of delayed-release dimethyl fumarate (DMF) on disease activity and PROs in patients with RRMS in the clinic. METHODS: PROTEC, a phase 4, open-label, 12-month observational study, assessed annualized relapse rate (ARR), proportion of patients relapsed, and changes in PROs. Newly diagnosed and early MS (≤3.5 EDSS and ≤1 relapse in the prior year) patient subgroups were evaluated. RESULTS: Unadjusted ARR at 12 months post-DMF versus 12 months before DMF initiation was 75% lower (0.161 vs. 0.643, p < 0.0001) overall (n = 1105) and 84%, 77%, and 71% lower in newly diagnosed, ≤3.5 EDSS, and ≤1 relapse subgroups, respectively. Overall, 88% of patients were relapse-free 12 months after DMF initiation (84%, newly diagnosed; 88%, ≤3.5 EDSS; 88%, ≤1 relapse). PRO measures for fatigue, treatment satisfaction, daily living, and work improved significantly over 12 months of DMF versus baseline. CONCLUSION: At 12 months after versus 12 months before DMF initiation, ARR was significantly lower, the majority of patients were relapse-free, and multiple PRO measures showed improvement (overall and for subgroups), suggesting that DMF is effective based on clinical outcomes and from a patient perspective.Clinical trial: A Study Evaluating the Effectiveness of Tecfidera (Dimethyl Fumarate) on Multiple Sclerosis (MS) Disease Activity and Patient-Reported Outcomes (PROTEC), NCT01930708,info:eu-repo/semantics/publishedVersio

    Heterotic Black Horizons

    Full text link
    We show that the supersymmetric near horizon geometry of heterotic black holes is either an AdS_3 fibration over a 7-dimensional manifold which admits a G_2 structure compatible with a connection with skew-symmetric torsion, or it is a product R^{1,1} * S^8, where S^8 is a holonomy Spin(7) manifold, preserving 2 and 1 supersymmetries respectively. Moreover, we demonstrate that the AdS_3 class of heterotic horizons can preserve 4, 6 and 8 supersymmetries provided that the geometry of the base space is further restricted. Similarly R^{1,1} * S^8 horizons with extended supersymmetry are products of R^{1,1} with special holonomy manifolds. We have also found that the heterotic horizons with 8 supersymmetries are locally isometric to AdS_3 * S^3 * T^4, AdS_3 * S^3 * K_3 or R^{1,1} * T^4 * K_3, where the radii of AdS_3 and S^3 are equal and the dilaton is constant.Comment: 35 pages, latex. Minor alterations to equation (3.11) and section 4.1, the conclusions are not affecte

    Within You / Without You: Biotechnology, Ontology, and Ethics

    Get PDF
    As Implantable Cardioverter Defibrillators (ICDs) have become more common, ethical issues have arisen regarding the deactivation of these devices. Goldstein et al., have shown that both patients and cardiologists consider ICD deactivation to be different from the discontinuation of other life-sustaining treatments. It cannot be argued ethically that ICDs raise new questions about the distinction between withholding and withdrawing treatment, and neither the fact that they are used intermittently, nor the duration of therapy, nor the mere fact that they are located inside the body can be considered unique to these devices and morally decisive. However, frequent allusions to the fact that they are located inside the body might provide a clue about what bothers patients and physicians. As technology progresses, some interventions seem to become a part of the patient as a unified whole person, completely replacing body parts and lost physiological functions rather than merely substituting for impaired structure and function. If a life-sustaining intervention can be considered a “replacement”—a part of the patient as a unified whole person—then it seems that deactivation is better classified as a case of killing rather than a case of forgoing a life-sustaining treatment. ICDs are not a “replacement” therapy in this sense. The deactivation of an ICD is best classified, under the proper conditions, as the forgoing of an extraordinary means of care. As technology becomes more sophisticated, however, and new interventions come to be best classified as “replacements” (a heart transplant would be a good example), “discontinuing” these interventions should be much more morally troubling for those clinicians who oppose euthanasia and assisted suicide

    Seven day pre-analytical stability of serum and plasma neurofilament light chain.

    Get PDF
    Neurofilament light chain (NfL) has emerged as a biomarker of neuroaxonal damage in several neurologic conditions. With increasing availability of fourth-generation immunoassays detecting NfL in blood, aspects of pre-analytical stability of this biomarker remain unanswered. This study investigated NfL concentrations in serum and plasma samples of 32 patients with neurological diagnoses using state of the art Simoa technology. We tested the effect of delayed freezing of up to 7 days and statistically determined stability and validity of measured concentrations. We found concentrations of NfL in serum and plasma to remain stable at room temperature when processing of samples is delayed up to 7 days (serum: mean absolute difference 0.9 pg/mL, intraindividual variation 1.2%; plasma: mean absolute difference 0.5 pg/mL, intraindividual variation 1.3%). Consistency of these results was nearly perfect for serum and excellent for plasma (intraclass correlation coefficients 0.99 and 0.94, respectively). In conclusion, the soluble serum and plasma NfL concentration remains stable when unprocessed blood samples are stored up to 7 days at room temperature. This information is essential for ensuring reliable study protocols, for example, when shipment of fresh samples is needed

    Increased serum neurofilament light chain concentration indicates poor outcome in Guillain-Barré syndrome

    Get PDF
    BACKGROUND Guillain-Barré syndrome (GBS) is an autoimmune disease that results in demyelination and axonal damage. Five percent of patients die and 20% remain significantly disabled on recovery. Recovery is slow in most cases and eventual disability is difficult to predict, especially early in the disease. Blood or cerebrospinal fluid (CSF) biomarkers that could help identify patients at risk of poor outcome are required. We measured serum neurofilament light chain (sNfL) concentrations from blood taken upon admission and investigated a correlation between sNfL and clinical outcome. METHODS Baseline sNfL levels in 27 GBS patients were compared with a control group of 22 patients with diagnoses not suggestive of any axonal damage. Clinical outcome parameters for GBS patients included (i) the Hughes Functional Score (HFS) at admission, nadir, and discharge; (ii) the number of days hospitalised; and (iii) whether intensive care was necessary. RESULTS The median sNfL concentration in our GBS sample on admission was 85.5 pg/ml versus 9.1 pg/ml in controls. A twofold increase in sNfL concentration at baseline was associated with an HFS increase of 0.6 at nadir and reduced the likelihood of discharge with favourable outcome by a factor of almost three. Higher sNfL levels upon admission correlated well with hospitalisation time (rs = 0.69, p < 0.0001), during which transfer to intensive care occurred more frequently at an odds ratio of 2.4. Patients with baseline sNfL levels below 85.5 pg/ml had a 93% chance of being discharged with an unimpaired walking ability. CONCLUSIONS sNfL levels measured at hospital admission correlated with clinical outcome in GBS patients. These results represent amounts of acute axonal damage and reflect mechanisms resulting in disability in GBS. Thus, sNfL may serve as a convenient blood-borne biomarker to personalise patient care by identifying those at higher risk of poor outcome

    Calibration estimation in dual-frame surveys

    Get PDF
    Survey statisticians make use of auxiliary information to improve estimates. One important example is calibration estimation, which constructs new weights that match benchmark constraints on auxiliary variables while remaining “close” to the design weights. Multiple-frame surveys are increasingly used by statistical agencies and private organizations to reduce sampling costs and/or avoid frame undercoverage errors. Several ways of combining estimates derived from such frames have been proposed elsewhere; in this paper, we extend the calibration paradigm, previously used for single-frame surveys, to calculate the total value of a variable of interest in a dual-frame survey. Calibration is a general tool that allows to include auxiliary information from two frames. It also incorporates, as a special case, certain dual-frame estimators that have been proposed previously. The theoretical properties of our class of estimators are derived and discussed, and simulation studies conducted to compare the efficiency of the procedure, using different sets of auxiliary variables. Finally, the proposed methodology is applied to real data obtained from the Barometer of Culture of Andalusia survey.Ministerio de Educación y CienciaConsejería de Economía, Innovación, Ciencia y EmpleoPRIN-SURWE

    Magnetic Coupling in the Quiet Solar Atmosphere

    Full text link
    Three kinds of magnetic couplings in the quiet solar atmosphere are highlighted and discussed, all fundamentally connected to the Lorentz force. First the coupling of the convecting and overshooting fluid in the surface layers of the Sun with the magnetic field. Here, the plasma motion provides the dominant force, which shapes the magnetic field and drives the surface dynamo. Progress in the understanding of the horizontal magnetic field is summarized and discussed. Second, the coupling between acoustic waves and the magnetic field, in particular the phenomenon of wave conversion and wave refraction. It is described how measurements of wave travel times in the atmosphere can provide information about the topography of the wave conversion zone, i.e., the surface of equal Alfv\'en and sound speed. In quiet regions, this surface separates a highly dynamic magnetic field with fast moving magnetosonic waves and shocks around and above it from the more slowly evolving field of high-beta plasma below it. Third, the magnetic field also couples to the radiation field, which leads to radiative flux channeling and increased anisotropy in the radiation field. It is shown how faculae can be understood in terms of this effect. The article starts with an introduction to the magnetic field of the quiet Sun in the light of new results from the Hinode space observatory and with a brief survey of measurements of the turbulent magnetic field with the help of the Hanle effect.Comment: To appear in "Magnetic Coupling between the Interior and the Atmosphere of the Sun", eds. S.S. Hasan and R.J. Rutten, Astrophysics and Space Science Proceedings, Springer-Verlag, Heidelberg, Berlin, 200

    A frequentist framework of inductive reasoning

    Full text link
    Reacting against the limitation of statistics to decision procedures, R. A. Fisher proposed for inductive reasoning the use of the fiducial distribution, a parameter-space distribution of epistemological probability transferred directly from limiting relative frequencies rather than computed according to the Bayes update rule. The proposal is developed as follows using the confidence measure of a scalar parameter of interest. (With the restriction to one-dimensional parameter space, a confidence measure is essentially a fiducial probability distribution free of complications involving ancillary statistics.) A betting game establishes a sense in which confidence measures are the only reliable inferential probability distributions. The equality between the probabilities encoded in a confidence measure and the coverage rates of the corresponding confidence intervals ensures that the measure's rule for assigning confidence levels to hypotheses is uniquely minimax in the game. Although a confidence measure can be computed without any prior distribution, previous knowledge can be incorporated into confidence-based reasoning. To adjust a p-value or confidence interval for prior information, the confidence measure from the observed data can be combined with one or more independent confidence measures representing previous agent opinion. (The former confidence measure may correspond to a posterior distribution with frequentist matching of coverage probabilities.) The representation of subjective knowledge in terms of confidence measures rather than prior probability distributions preserves approximate frequentist validity.Comment: major revisio

    Quantization of Midisuperspace Models

    Get PDF
    We give a comprehensive review of the quantization of midisuperspace models. Though the main focus of the paper is on quantum aspects, we also provide an introduction to several classical points related to the definition of these models. We cover some important issues, in particular, the use of the principle of symmetric criticality as a very useful tool to obtain the required Hamiltonian formulations. Two main types of reductions are discussed: those involving metrics with two Killing vector fields and spherically symmetric models. We also review the more general models obtained by coupling matter fields to these systems. Throughout the paper we give separate discussions for standard quantizations using geometrodynamical variables and those relying on loop quantum gravity inspired methods.Comment: To appear in Living Review in Relativit
    corecore