29 research outputs found

    Sacrificial charge and the spectral resolution performance of the Chandra Advanced CCD Imaging Spectrometer

    Get PDF
    Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. The ACIS team is continuing to study the properties of the damage with an emphasis on developing techniques to mitigate charge transfer inefficiency (CTI) and spectral resolution degradation. A post-facto CTI corrector has been developed which can effectively recover much of the lost resolution. Any further improvements in performance will require knowledge of the location and amount of sacrificial charge - charge deposited along the readout path of an event which fills electron traps and changes CTI. We report on efforts by the ACIS Instrument team to characterize which charge traps cause performance degradation and the properties of the sacrificial charge seen on-orbit. We also report on attempts to correct X-ray pulseheights for the presence of sacrificial charge.Comment: 9 pages, 7 figures to be published in Proc. SPIE 485

    Refining Chandra/ACIS Subpixel Event Repositioning Using a Backside Illuminated CCD Model

    Get PDF
    Subpixel event repositioning (SER) techniques have been demonstrated to significantly improve the already unprecedented spatial resolution of Chandra X-ray imaging with the Advanced CCD Imaging Spectrometer (ACIS). Chandra CCD SER techniques are based on the premise that the impact position of events can be refined, based on the distribution of charge among affected CCD pixels. ACIS SER models proposed thus far are restricted to corner split (3- and 4-pixel) events, and assume that such events take place at the split pixel corners. To improve the event counting statistics, we modified the ACIS SER algorithms to include 2-pixel split events and single pixel events, using refined estimates for photon impact locations. Furthermore, simulations that make use of a high-fidelity backside illuminated (BI) CCD model demonstrate that mean photon impact positions for split events are energy dependent leading to further modification of subpixel event locations according to event type and energy, for BI ACIS devices. Testing on Chandra CCD X-ray observations of the Orion Nebula Cluster indicates that these modified SER algorithms further improve the spatial resolution of Chandra/ACIS, to the extent that the spreading in the spatial distribution of photons is dominated by the High Resolution Mirror Assembly, rather than by ACIS pixelization.Comment: 23 pages, 8 figures, 2nd version, submitted to Ap

    Event-driven charge-coupled device design and applications therefor

    Get PDF
    An event-driven X-ray CCD imager device uses a floating-gate amplifier or other non-destructive readout device to non-destructively sense a charge level in a charge packet associated with a pixel. The output of the floating-gate amplifier is used to identify each pixel that has a charge level above a predetermined threshold. If the charge level is above a predetermined threshold the charge in the triggering charge packet and in the charge packets from neighboring pixels need to be measured accurately. A charge delay register is included in the event-driven X-ray CCD imager device to enable recovery of the charge packets from neighboring pixels for accurate measurement. When a charge packet reaches the end of the charge delay register, control logic either dumps the charge packet, or steers the charge packet to a charge FIFO to preserve it if the charge packet is determined to be a packet that needs accurate measurement. A floating-diffusion amplifier or other low-noise output stage device, which converts charge level to a voltage level with high precision, provides final measurement of the charge packets. The voltage level is eventually digitized by a high linearity ADC

    Chandra/ACIS Subpixel Event Repositioning. II. Further Refinements and Comparison between Backside and Front-side Illuminated X-ray CCDs

    Get PDF
    We further investigate subpixel event repositioning (SER) algorithms in application to Chandra X-ray Observatory (CXO) CCD imaging. SER algorithms have been applied to backside illuminated (BI) Advanced CCD Imaging Spectrometer (ACIS) devices, and demonstrate spatial resolution improvements in Chandra/ACIS observations. Here a new SER algorithm that is charge split dependent is added to the SER family. We describe the application of SER algorithms to frontside illuminated (FI) ACIS devices. The results of SER for FI CCDs are compared with those obtained from SER techniques applied to BI CCD event data. Both simulated data and Chandra/ACIS observations of the Orion Nebular Cluster were used to test and evaluate the achievement of the various SER techniques.Comment: 30 pages, 9 figures, submitted to Ap

    Ground calibration of the Silicon Drift Detectors for NICER

    Get PDF
    The Neutron star Interior Composition ExploreR (NICER) is set to be deployed on the International Space Station (ISS) in early 2017. It will use an array of 56 Silicon Drift Detectors (SDDs) to detect soft X-rays (0.2 - 12 keV) with 100 nanosecond timing resolution. Here we describe the effort to calibrate the detectors in the lab primarily using a Modulated X-ray Source (MXS). The MXS that was customized for NICER provides more than a dozen emission lines spread over the instrument bandwidth, providing calibration measurements for detector gain and spectral resolution. In addition, the fluorescence source in the MXS was pulsed at high frequency to enable measurement of the delay due to charge collection in the silicon and signal processing in the detector electronics. A second chamber, designed to illuminate detectors with either 55 Fe, an optical LED, or neither, provided additional calibration of detector response, optical blocking, and effectiveness of background rejection techniques. The overall ground calibration achieved total operating time that was generally in the range of 500-1500 hours for each of the 56 detectors. Keywords: Silicon Drift Detectors; X-rays; timing spectroscopy; calibrationUnited States. National Aeronautics and Space Administration (Contract NNG14PJ13C

    Single electron Sensitive Readout (SiSeRO) X-ray detectors: Technological progress and characterization

    Full text link
    Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors. Developed at MIT Lincoln Laboratory, this technology uses a p-MOSFET transistor with a depleted internal gate beneath the transistor channel. The transistor source-drain current is modulated by the transfer of charge into the internal gate. At Stanford, we have developed a readout module based on the drain current of the on-chip transistor to characterize the device. Characterization was performed for a number of prototype sensors with different device architectures, e.g. location of the internal gate, MOSFET polysilicon gate structure, and location of the trough in the internal gate with respect to the source and drain of the MOSFET (the trough is introduced to confine the charge in the internal gate). Using a buried-channel SiSeRO, we have achieved a charge/current conversion gain of >700 pA per electron, an equivalent noise charge (ENC) of around 6 electrons root mean square (RMS), and a full width half maximum (FWHM) of approximately 140 eV at 5.9 keV at a readout speed of 625 Kpixel/s. In this paper, we discuss the SiSeRO working principle, the readout module developed at Stanford, and the characterization test results of the SiSeRO prototypes. We also discuss the potential to implement Repetitive Non-Destructive Readout (RNDR) with these devices and the preliminary results which can in principle yield sub-electron ENC performance. Additional measurements and detailed device simulations will be essential to mature the SiSeRO technology. However, this new device class presents an exciting technology for next generation astronomical X-ray telescopes requiring fast, low-noise, radiation hard megapixel imagers with moderate spectroscopic resolution.Comment: To appear in SPIE Proceedings of Astronomical Telescopes + Instrumentation, 202

    Testing and characterization of the TESS CCDs

    Get PDF
    The Transiting Exoplanet Survey Satellite (TESS) is an Explorer-class mission dedicated to finding planets around bright, nearby stars so that more detailed follow-up studies can be done. TESS is due to launch in 2017 and careful characterization of the detectors will need to be completed on ground before then to ensure that the cameras will be within their photometric requirement of 60ppm/hr. TESS will fly MITLincoln Laboratories CCID-80s as the main scientific detector for its four cameras. They are 100μm deep depletion devices which have low dark current noise levels and can operate at low light levels at room temperature. They also each have a frame store region, which reduces smearing during readout and allows for near continuous integration. This paper describes the hardware and methodology that were developed for testing and characterizing individual CCID-80s. A dark system with no stimuli was used to measure the dark current. Fe 55 and Cd 109 X-ray sources were used to establish gain at low signal levels and its temperature dependence. An LED system that generates a programmable series of pulses was used in conjunction with an integrating sphere to measure pixel response non-uniformity (PRNU) and gain at higher signal levels. The same LED system was used with a pinhole system to evaluate the linearity and charge conservation capability of the CCID-80s.United States. National Aeronautics and Space Administration (contract number NNG14FC03C

    A NICER look at the Aql X-1 hard state

    Get PDF
    We report on a spectral-timing analysis of the neutron star low-mass X-ray binary (LMXB) Aql X-1 with the Neutron Star Interior Composition Explorer (NICER) on the International Space Station (ISS). Aql X-1 was observed with NICER during a dim outburst in 2017 July, collecting approximately 50 ks of good exposure. The spectral and timing properties of the source correspond to that of a (hard) extreme island state in the atoll classification. We find that the fractional amplitude of the low-frequency (<0.3 Hz) band-limited noise shows a dramatic turnover as a function of energy: it peaks at 0.5 keV with nearly 25% rms, drops to 12% rms at 2 keV, and rises to 15% rms at 10 keV. Through the analysis of covariance spectra, we demonstrate that band-limited noise exists in both the soft thermal emission and the power-law emission. Additionally, we measure hard time lags, indicating the thermal emission at 0.5 keV leads the power-law emission at 10 keV on a timescale of ∼100 ms at 0.3 Hz to ∼10 ms at 3 Hz. Our results demonstrate that the thermal emission in the hard state is intrinsically variable, and is driving the modulation of the higher energy power-law. Interpreting the thermal spectrum as disk emission, we find that our results are consistent with the disk propagation model proposed for accretion onto black holes.United States. National Aeronautics and Space Administration. Neutron Star Interior Composition ExplorerUnited States. National Aeronautics and Space Administration. Astrophysics Research and Analysis Progra

    The high-speed X-ray camera on AXIS

    Full text link
    AXIS is a Probe-class mission concept that will provide high-throughput, high-spatial-resolution X-ray spectral imaging, enabling transformative studies of high-energy astrophysical phenomena. To take advantage of the advanced optics and avoid photon pile-up, the AXIS focal plane requires detectors with readout rates at least 20 times faster than previous soft X-ray imaging spectrometers flying aboard missions such as Chandra and Suzaku, while retaining the low noise, excellent spectral performance, and low power requirements of those instruments. We present the design of the AXIS high-speed X-ray camera, which baselines large-format MIT Lincoln Laboratory CCDs employing low-noise pJFET output amplifiers and a single-layer polysilicon gate structure that allows fast, low-power clocking. These detectors are combined with an integrated high-speed, low-noise ASIC readout chip from Stanford University that provides better performance than conventional discrete solutions at a fraction of their power consumption and footprint. Our complementary front-end electronics concept employs state of the art digital video waveform capture and advanced signal processing to deliver low noise at high speed. We review the current performance of this technology, highlighting recent improvements on prototype devices that achieve excellent noise characteristics at the required readout rate. We present measurements of the CCD spectral response across the AXIS energy band, augmenting lab measurements with detector simulations that help us understand sources of charge loss and evaluate the quality of the CCD backside passivation technique. We show that our technology is on a path that will meet our requirements and enable AXIS to achieve world-class science.Comment: 17 pages, 11 figures, submitted to Proceedings of SPIE Optics + Photonics 202

    The Neutron star Interior Composition Explorer (NICER): design and development

    Get PDF
    During 2014 and 2015, NASA's Neutron star Interior Composition Explorer (NICER) mission proceeded successfully through Phase C, Design and Development. An X-ray (0.2-12 keV) astrophysics payload destined for the International Space Station, NICER is manifested for launch in early 2017 on the Commercial Resupply Services SpaceX-11 flight. Its scientific objectives are to investigate the internal structure, dynamics, and energetics of neutron stars, the densest objects in the universe. During Phase C, flight components including optics, detectors, the optical bench, pointing actuators, electronics, and others were subjected to environmental testing and integrated to form the flight payload. A custom-built facility was used to co-align and integrate the X-ray "concentrator" optics and silicon-drift detectors. Ground calibration provided robust performance measures of the optical (at NASA's Goddard Space Flight Center) and detector (at the Massachusetts Institute of Technology) subsystems, while comprehensive functional tests prior to payload-level environmental testing met all instrument performance requirements. We describe here the implementation of NICER's major subsystems, summarize their performance and calibration, and outline the component-level testing that was successfully applied
    corecore