42 research outputs found
Measurement of the energy resolution and calibration of hybrid pixel detectors with GaAs:Cr sensor and Timepix readout chip
This paper describes an iterative method of per-pixel energy calibration of
hybrid pixel detectors with GaAs:Cr sensor and Timepix readout chip. A
convolution of precisely measured spectra of characteristic X-rays of different
metals with the resolution and the efficiency of the pixel detector is used for
the calibration. The energy resolution of the detector is also measured during
the calibration. The use of per-pixel calibration allows to achieve a good
energy resolution of the Timepix detector with GaAs:Cr sensor: 8% and 13% at 60
keV and 20 keV, respectively
Search for the decay
We performed a search for the decay with the
E391a detector at KEK. In the data accumulated in 2005, no event was observed
in the signal region. Based on the assumption of
proceeding via parity-violation, we obtained the single event sensitivity to be
, and set an upper limit on the branching ratio to
be at the 90% confidence level. This is a factor of 3.2
improvement compared to the previous results. The results of proceeding via parity-conservation were also presented in this paper
Experimental study of the decay
The first dedicated search for the rare neutral-kaon decay
has been carried out in the E391a experiment at the
KEK 12-GeV proton synchrotron. The final upper limit of 2.6 at
the 90% confidence level was set on the branching ratio for the decay.Comment: 23 pages, 27 figures, accepted for publication as a regular article
in Physical Review
Spin physics with antiprotons
New possibilities arising from the availability at GSI of antiproton beams,
possibly polarised, are discussed. The investigation of the nucleon structure
can be boosted by accessing in Drell-Yan processes experimental asymmetries
related to cross-sections in which the parton distribution functions (PDF) only
appear, without any contribution from fragmentation functions; such processes
are not affected by the chiral suppression of the transversity function
. Spin asymmetries in hyperon production and Single Spin Asymmetries
are discussed as well, together with further items like electric and magnetic
nucleonic form factors and open charm production. Counting rates estimations
are provided for each physical case. The sketch of a possible experimental
apparatus is proposed.Comment: Presented for the proceedings of ASI "Spin and Symmetry", Prague,
July 5-10, 2004, to be published in Czech. J. Phys. 55 (2005
The OLVE-HERO Calorimeter Prototype Tests at Heavy Ion Beams of CERN SPS
A project of the OLVE-HERO space detector is proposed for CR measurement in the range of 10–10 eV and will include a large ionization-neutron 3D calorimeter with a high granularity and geometric factor of ~16 m sr. The main OLVE-HERO detector is expecte to be image calorimeter of a boron loaded plastic scintillator with a tungsten absorber. Such a calorimeter allows to measure an additional neutron signal which will improve the energy resolution of the detector. More importantly, the rejection power between electromagnetic and nuclear CR components will be increased by factor 30–50 in the whole energy range. The boron loaded scintillator detector prototype was designed and tested at the H8 beam test area at CERN SPS during Pb ion run in 2016 and Xe ion run in 2017. The results of the beam tests and the corresponding Monte-Carlo simulation are presented