252 research outputs found

    Novel metallic implantation technique for osteochondral defects of the medial talar dome: A cadaver study

    Get PDF
    BACKGROUND AND PURPOSE: A metallic inlay implant (HemiCAP) with 15 offset sizes has been developed for the treatment of localized osteochondral defects of the medial talar dome. The aim of this study was to test the following hypotheses: (1) a matching offset size is available for each talus, (2) the prosthetic device can be reproducibly implanted slightly recessed in relation to the talar cartilage level, and (3) with this implantation level, excessive contact pressures on the opposite tibial cartilage are avoided. METHODS: The prosthetic device was implanted in 11 intact fresh-frozen human cadaver ankles, aiming its surface 0.5 mm below cartilage level. The implantation level was measured at 4 margins of each implant. Intraarticular contact pressures were measured before and after implantation, with compressive forces of 1,000-2,000 N and the ankle joint in plantigrade position, 10 dorsiflexion, and 14 plantar flexion. RESULTS: There was a matching offset size available for each specimen. The mean implantation level was 0.45 (SD 0.18) mm below the cartilage surface. The defect area accounted for a median of 3% (0.02-18) of the total ankle contact pressure before implantation. This was reduced to 0.1% (0.02-13) after prosthetic implantation. INTERPRETATION: These results suggest that the implant can be applied clinically in a safe way, with appropriate offset sizes for various talar domes and without excessive pressure on the opposite cartilag

    Buffer substitution in malaria rapid diagnostic tests causes false-positive results

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Malaria rapid diagnostic tests (RDTs) are kits that generally include 20 to 25 test strips or cassettes, but only a single buffer vial. In field settings, laboratory staff occasionally uses saline, distilled water (liquids for parenteral drugs dilution) or tap water as substitutes for the RDT kit's buffer to compensate for the loss of a diluent bottle. The present study assessed the effect of buffer substitution on the RDT results.</p> <p>Methods</p> <p>Twenty-seven RDT brands were run with EDTA-blood samples of five malaria-free subjects, who were negative for rheumatoid factor and antinuclear antibodies. Saline, distilled water and tap water were used as substitute liquids. RDTs were also run with distilled water, without adding blood. Results were compared to those obtained with the RDT kit's buffer and <it>Plasmodium </it>positive samples.</p> <p>Results</p> <p>Only eight cassettes (in four RDT brands) showed no control line and were considered invalid. Visible test lines occurred for at least one malaria-free sample and one of the substitutes in 20/27 (74%) RDT brands (saline: n = 16; distilled water: n = 17; and tap water: n = 20), and in 15 RDTs which were run with distilled water only. They occurred for all <it>Plasmodium </it>antigens and RDT formats (two-, three- and four-band RDTs). Clearance of the background of the strip was excellent except for saline. The aspects (colour, intensity and crispness) of the control and the false-positive test lines were similar to those obtained with the RDT kits' buffer and <it>Plasmodium </it>positive samples.</p> <p>Conclusion</p> <p>Replacement of the RDT kit's dedicated buffer by saline, distilled water and tap water can cause false-positive test results.</p

    Evaluation of the rapid diagnostic test SDFK40 (Pf-pLDH/pan-pLDH) for the diagnosis of malaria in a non-endemic setting

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The present study evaluated the SD Bioline Malaria Ag 05FK40 (SDFK40), a three-band RDT detecting <it>Plasmodium falciparum</it>-specific parasite lactate dehydrogenase (Pf-pLDH) and pan <it>Plasmodium</it>-specific pLDH (pan-pLDH), in a reference setting.</p> <p>Methods</p> <p>The SDFK40 was retrospectively and prospectively tested against a panel of stored (n = 341) and fresh (n = 181) whole blood samples obtained in international travelers suspected of malaria, representing the four <it>Plasmodium </it>species as well as <it>Plasmodium </it>negative samples, and compared to microscopy and PCR results. The prospective panel was run together with OptiMAL (Pf-pLDH/pan-pLDH) and SDFK60 (histidine-rich protein-2 (HRP-2)/pan-pLDH).</p> <p>Results</p> <p>Overall sensitivities for <it>P. falciparum </it>tested retrospectively and prospectively were 67.9% and 78.8%, reaching 100% and 94.6% at parasite densities >1,000/μl. Sensitivity at parasite densities ≤ 100/μl was 9.1%. Overall sensitivities for <it>Plasmodium vivax </it>and <it>Plasmodium ovale </it>were 86.7% and 80.0% (retrospectively) and 92.9% and 76.9% (prospectively), reaching 94.7% for both species (retrospective panel) at parasite densities >500/μl. Sensitivity for <it>Plasmodium malariae </it>was 21.4%. Species mismatch occurred in 0.7% of samples (3/411) and was limited to non-<it>falciparum </it>species erroneously identified as <it>P. falciparum</it>. None of the <it>Plasmodium </it>negative samples in the retrospective panel reacted positive. Compared to OptiMAL and SDFK60, SDFK40 showed lower sensitivities for <it>P. falciparum</it>, but better detection of <it>P. ovale</it>. Inter-observer agreement and test reproducibility were excellent, but lot-to-lot variability was observed for pan-pLDH results in case of <it>P. falciparum</it>.</p> <p>Conclusion</p> <p>SDFK40 performance was poor at low (≤ 100/μl) parasite densities, precluding its use as the only diagnostic tool for malaria diagnosis. SDFK40 performed excellent for <it>P. falciparum </it>samples at high (>1,000/μl) parasite densities as well as for detection of <it>P. vivax </it>and <it>P. ovale </it>at parasite densities >500/μl.</p

    Nanoparticles in cigarette smoke; real-time undiluted measurements by a scanning mobility particle sizer

    Get PDF
    Cigarette smoke is a complex mixture of smoke constituents, often characterised by size-resolved particle distributions. Since descriptions of ultrafine particles <50 nm are absent, our aim was to explore the existence of these nanoparticles in fresh and undiluted cigarette smoke. We measured undiluted smoke particles real-time by a scanning mobility particle sizer with Faraday cup electrometer, integrated in our custom-made smoking machine. Cigarettes were smoked by 2 s puffs, 30 s puff intervals and 50 ml puff volume. We tested six different cigarettes (1–10 mg tar per cigarette) at ten particle size-ranges between 6 and 50 nm, and repeated measurements five times. The formation of nanoparticles in fresh cigarette smoke was observed over the entire range between 6 and 50 nm, and reproduced in all cigarettes. The highest mean yield was 8.8 × 109 (SD = 1.1 × 109) particles per cigarette at the largest particle size range by high-tar cigarettes. Nanoparticle counts appear to increase with particle size, claimed tar values and blocking of filter ventilation holes, and inversely with butt length. Fresh undiluted cigarette smoke contains large amounts of potentially toxic nanoparticles <50 nm. We recommend to further study nanoparticles in the characterisation of cigarette smoke

    External quality assessment on the use of malaria rapid diagnostic tests in a non-endemic setting

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Malaria rapid diagnostic tests (RDTs) are increasingly used as a tool for the diagnosis of malaria, both in endemic and in non-endemic settings. The present study reports the results of an external quality assessment (EQA) session on RDTs in a non-endemic setting.</p> <p>Methods</p> <p>After validation of antigen stability during shipment at room temperature, three clinical samples and a questionnaire were sent to clinical laboratories in Belgium and the Grand Duchy of Luxembourg using malaria RDTs. Participants were asked to report the results of the RDTs as observations (visibility of the RDT control and test lines) and interpretations (report as formulated to the clinician). In addition, participants were invited to fill in a questionnaire on the place of RDTs in the diagnostic strategy of malaria.</p> <p>Results</p> <p>A total of 128/133 (96.2%) of clinical laboratories using RDTs participated. Six three-band and one four-band RDT brands were used. Analytical errors were rare and included (i) not recognizing invalid RDT results (1.6%) and (ii) missing the diagnosis of <it>Plasmodium falciparum </it>(0.8%). Minor errors were related to RDT test result interpretation and included (i) reporting "RDT positive" without species identification in the case of <it>P. falciparum </it>and non-<it>falciparum </it>species (16.9% and 6.5% respectively) and (ii) adding incorrect comments to the report (3.2%). Some of these errors were related to incorrect RDT package insert instructions such as (i) not reporting the possibility of mixed species infection in the case of <it>P. falciparum </it>and <it>Plasmodium vivax </it>(35.5% and 18.5% respectively) and (ii) the interpretation of <it>P. vivax </it>instead of non-falciparum species at the presence of a pan-species antigen line (4.0%). According to the questionnaire, 48.8% of participants processed ≤20 requests for malaria diagnosis in 2009. During opening hours, 93.6% of 125 participants used RDTs as an adjunct to microscopy but outside opening hours, nearly one third of 113 participants relied on RDTs as the primary (4.4%) or the single tool (25.7%) for malaria diagnosis.</p> <p>Conclusion</p> <p>In this non-endemic setting, errors in RDT performance were mainly related to RDT test line interpretations, partly due to incorrect package insert instructions. The reliance on RDTs as the primary or the single tool for the diagnosis of malaria outside opening hours is of concern and should be avoided.</p

    Work-related upper extremity disorders: one-year follow-up in an occupational diseases registry

    Get PDF
    To study the course and consequences of work-related upper extremity disorders in the registry of the Netherlands Centre for Occupational Diseases (NCvB). A follow-up study was performed in a sample of consecutive cases of work-related upper extremity disorders notified to the NCvB. Perceived severity was measured with VAS (0-100), quality of life with VAS (0-100) and SF-36, functional impairment with DASH and sickness absence with a questionnaire. Measurements took place directly after notification (T0) and after 3, 6 and 12 months (T1-T3). A linear mixed model was used to compare scores over time. Average age of the 48 consecutive patients (89% response) was 42 years; 48% were men. Perceived severity, functional impairment and sickness absence decreased statistically significant during the follow-up period, and quality of life scores improved. Patients older than 45 years scored worse on perceived severity of the disease, functional impairment and quality of life than did younger patients. The role of registries of occupational diseases for preventive policy can be extended by creating longitudinal data in sample projects. In the sample from our registry, work-related upper extremity disorders had a favourable cours

    Malaria rapid diagnostic kits: quality of packaging, design and labelling of boxes and components and readability and accuracy of information inserts

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The present study assessed malaria RDT kits for adequate and correct packaging, design and labelling of boxes and components. Information inserts were studied for readability and accuracy of information.</p> <p>Methods</p> <p>Criteria for packaging, design, labelling and information were compiled from Directive 98/79 of the European Community (EC), relevant World Health Organization (WHO) documents and studies on end-users' performance of RDTs. Typography and readability level (Flesch-Kincaid grade level) were assessed.</p> <p>Results</p> <p>Forty-two RDT kits from 22 manufacturers were assessed, 35 of which had evidence of good manufacturing practice according to available information (<it>i.e</it>. CE-label affixed or inclusion in the WHO list of ISO13485:2003 certified manufacturers). Shortcomings in devices were (i) insufficient place for writing sample identification (n = 40) and (ii) ambiguous labelling of the reading window (n = 6). Buffer vial labels were lacking essential information (n = 24) or were of poor quality (n = 16). Information inserts had elevated readability levels (median Flesch Kincaid grade 8.9, range 7.1 - 12.9) and user-unfriendly typography (median font size 8, range 5 - 10). Inadequacies included (i) no referral to biosafety (n = 18), (ii) critical differences between depicted and real devices (n = 8), (iii) figures with unrealistic colours (n = 4), (iv) incomplete information about RDT line interpretations (n = 31) and no data on test characteristics (n = 8). Other problems included (i) kit names that referred to <it>Plasmodium vivax </it>although targeting a pan-species <it>Plasmodium </it>antigen (n = 4), (ii) not stating the identity of the pan-species antigen (n = 2) and (iii) slight but numerous differences in names displayed on boxes, device packages and information inserts. Three CE labelled RDT kits produced outside the EC had no authorized representative affixed and the shape and relative dimensions of the CE symbol affixed did not comply with the Directive 98/79/EC. Overall, RDTs with evidence of GMP scored better compared to those without but inadequacies were observed in both groups.</p> <p>Conclusion</p> <p>Overall, malaria RDTs showed shortcomings in quality of construction, design and labelling of boxes, device packages, devices and buffers. Information inserts were difficult to read and lacked relevant information.</p

    Pathophysiology and pathogenesis of circadian rhythm sleep disorders

    Get PDF
    Metabolic, physiological and behavioral processes exhibit 24-hour rhythms in most organisms, including humans. These rhythms are driven by a system of self-sustained clocks and are entrained by environmental cues such as light-dark cycles as well as food intake. In mammals, the circadian clock system is hierarchically organized such that the master clock in the suprachiasmatic nuclei of the hypothalamus integrates environmental information and synchronizes the phase of oscillators in peripheral tissues. The transcription and translation feedback loops of multiple clock genes are involved in the molecular mechanism of the circadian system. Disturbed circadian rhythms are known to be closely related to many diseases, including sleep disorders. Advanced sleep phase type, delayed sleep phase type and nonentrained type of circadian rhythm sleep disorders (CRSDs) are thought to result from disorganization of the circadian system. Evaluation of circadian phenotypes is indispensable to understanding the pathophysiology of CRSD. It is laborious and costly to assess an individual's circadian properties precisely, however, because the subject is usually required to stay in a laboratory environment free from external cues and masking effects for a minimum of several weeks. More convenient measurements of circadian rhythms are therefore needed to reduce patients' burden. In this review, we discuss the pathophysiology and pathogenesis of CRSD as well as surrogate measurements for assessing an individual's circadian phenotype

    Cardio-metabolic risk in 5-year-old children prenatally exposed to maternal psychosocial stress: the ABCD study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Recent evidence, both animal and human, suggests that modifiable factors during fetal and infant development predispose for cardiovascular disease in adult life and that they may become possible future targets for prevention. One of these factors is maternal psychosocial stress, but so far, few prospective studies have been able to investigate the longer-term effects of stress in detail, i.e. effects in childhood. Therefore, our general aim is to study whether prenatal maternal psychosocial stress is associated with an adverse cardio-metabolic risk profile in the child at age five.</p> <p>Methods/design</p> <p>Data are available from the Amsterdam Born Children and their Development (ABCD) study, a prospective birth cohort in the Netherlands. Between 2003-2004, 8,266 pregnant women filled out a questionnaire including instruments to determine anxiety (STAI), pregnancy related anxiety (PRAQ), depressive symptoms (CES-D), parenting stress (PDH scale) and work stress (Job Content Questionnaire).</p> <p>Outcome measures in the offspring (age 5-7) are currently collected. These include lipid profile, blood glucose, insulin sensitivity, body composition (body mass index, waist circumference and bioelectrical impedance analysis), autonomic nervous system activity (parasympathetic and sympathetic measures) and blood pressure.</p> <p>Potential mediators are maternal serum cortisol, gestational age and birth weight for gestational age (intrauterine growth restriction). Possible gender differences in programming are also studied.</p> <p>Discussion</p> <p>Main strengths of the proposed study are the longitudinal measurements during three important periods (pregnancy, infancy and childhood), the extensive measurement of maternal psychosocial stress with validated questionnaires and the thorough measurement of the children's cardio-metabolic profile. The availability of several confounding factors will give us the opportunity to quantify the independent contribution of maternal stress during pregnancy to the cardio-metabolic risk profile of her offspring. Moreover, the mediating role of maternal cortisol, intrauterine growth, gestational age and potential gender differences can be explored extensively. If prenatal psychosocial stress is indeed found to be associated with the offspring's cardio-metabolic risk, these results support the statement that primary prevention of cardiovascular disease may start even before birth by reducing maternal stress during pregnancy.</p
    corecore